ABB EPX-XT2N-E2-1603 (1SDX254825R1) is a 160 A three-pole SACE Tmax XT2N160 moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and ABB Ekip LSI electronic protection. Designed for compatible ABB Protecta Power distribution assemblies, it provides long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection for three-phase outgoing circuits.
£1,412.80
The ABB EPX-XT2N-E2-1603 is a high-performance 160 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT2N160 circuit breaker platform, this protective device combines compact construction with advanced electronic trip technology for commercial, industrial and building services applications.
Part of the ABB Protecta Power Devices product group, the EPX-XT2N-E2-1603 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its ABB Ekip LSI electronic trip configuration provides long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection. These three protection functions offer electrical engineers greater flexibility when coordinating circuit protection across a low-voltage distribution network.
With a 160 A rated current, a specified 36 kA short-circuit breaking capacity and a three-pole (3P) configuration, the EPX-XT2N-E2-1603 is suitable for appropriately designed three-phase outgoing feeders, commercial distribution boards, industrial electrical panels and building services installations. Its 90 mm nominal device width supports efficient use of space within compatible distribution assemblies.
Identified by ABB order code 1SDX254825R1, this electronic MCCB provides electrical contractors, consulting engineers, panel builders and facilities managers with a clearly specified solution for 160 A circuit protection where configurable electronic trip characteristics and dependable short-circuit performance are essential.
The ABB EPX-XT2N-E2-1603 160 A electronic MCCB is designed to help maintain the safety and reliability of low-voltage electrical distribution networks. Moulded case circuit breakers interrupt current when abnormal operating conditions occur, helping protect electrical cables, distribution equipment and connected loads against the damaging effects of overloads and short circuits.
Unlike a conventional thermal-magnetic circuit breaker, the EPX-XT2N-E2-1603 uses an electronic trip release to monitor current conditions and initiate tripping according to the selected protection characteristics. This provides electrical engineers with additional flexibility when coordinating protective devices across commercial and industrial distribution systems.
The ABB Ekip LSI electronic trip configuration provides three distinct protection functions. Long-time protection (L) responds to sustained overload conditions that could otherwise cause overheating of conductors and connected electrical equipment. Short-time protection (S) provides delayed short-circuit protection, allowing engineers to consider coordination with downstream protective devices. Instantaneous protection (I) provides rapid operation under high short-circuit current conditions.
The distinction between LSI and LS/I is important when specifying electronic MCCBs. An LSI release provides long-time, short-time and instantaneous protection functions within the same protection arrangement. An LS/I release provides long-time protection together with a choice between short-time and instantaneous short-circuit protection modes. The LSI configuration therefore offers additional flexibility for electrical installations requiring a coordinated protection strategy.
The three-pole construction enables coordinated protection and switching of the three phase conductors. This makes the EPX-XT2N-E2-1603 suitable for three-phase outgoing feeders, industrial distribution circuits and commercial electrical installations where a dedicated switched neutral pole is not required.
Built around the ABB SACE Tmax XT2N160 platform, the EPX-XT2N-E2-1603 combines a 160 A rated current with a specified 36 kA short-circuit breaking capacity. Its 90 mm nominal width helps engineers plan compact distribution board layouts while retaining the protection flexibility associated with electronic trip technology.
Correct circuit breaker selection should consider the installation operating voltage, prospective short-circuit current, conductor sizing, electronic trip settings, selectivity requirements and compatibility with the distribution assembly. The applicable breaking capacity and exact Ekip LSI adjustment ranges should be verified against the relevant ABB technical documentation before installation and commissioning.
| Product group | Protecta Power Devices |
|---|---|
| Product range | SACE Tmax XT |
| Circuit breaker platform | XT2N160 |
| Model / SKU | EPX-XT2N-E2-1603 |
| ABB order code | 1SDX254825R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 160 A |
| Frame rating | 160 A |
| Short-circuit breaking capacity | 36 kA (specified Protecta Power application) |
| Number of poles | 3 |
| Pole configuration | Three-pole (3P) |
| Trip unit designation | Ekip LSI |
| Trip technology | Electronic |
| Protection designation | LSI |
| Long-time protection (L) | Overload protection |
| Short-time protection (S) | Delayed short-circuit protection |
| Instantaneous protection (I) | Instantaneous short-circuit protection |
| Protection arrangement | Long-time, short-time and instantaneous overcurrent protection |
| Electronic trip adjustment | Refer to the fitted ABB Ekip LSI release documentation |
| Neutral switching | No dedicated switched neutral pole |
| Applicable circuit breaker standard | IEC 60947-2 |
| Nominal device width | 90 mm |
| Installation type | Fixed installation within a compatible distribution assembly |
| Mounting compatibility | ABB Protecta Power, subject to appropriate mounting and connection arrangements |
| Electrical application | Three-phase low-voltage power distribution |
| Typical use | Outgoing feeder and sub-distribution circuit protection |
The ABB EPX-XT2N-E2-1603 is a 160 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It features an ABB Ekip LSI electronic trip configuration and is intended for compatible ABB Protecta Power distribution assemblies.
The EPX-XT2N-E2-1603 has a 160 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB SACE Tmax XT2N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be checked against the installation operating voltage and prospective fault current.
LSI stands for Long-time, Short-time and Instantaneous protection. Long-time protection responds to sustained overloads, short-time protection provides delayed short-circuit protection and instantaneous protection provides rapid operation under high fault-current conditions. These functions help engineers configure a coordinated circuit protection strategy.
An LSI MCCB provides long-time, short-time and instantaneous protection functions together. An LS/I MCCB provides long-time overload protection with a choice between short-time and instantaneous short-circuit protection modes. The LSI arrangement offers additional flexibility where both delayed and instantaneous short-circuit protection characteristics are required.
The breaker is intended for installation within compatible ABB Protecta Power distribution boards, using the appropriate mounting and connection arrangements. The ABB XT2 three-pole platform has a nominal width of 90 mm. Installation and electronic trip configuration should be carried out by a competent electrical professional in accordance with the circuit design and applicable electrical regulations.
ABB SACE Tmax XT moulded case circuit breakers are established components in low-voltage electrical distribution, providing dependable protection for commercial and industrial installations. The ABB EPX-XT2N-E2-1603 combines a 160 A rated current, three-pole switching, specified 36 kA short-circuit breaking capacity and configurable ABB Ekip LSI electronic protection in a compact device intended for compatible ABB Protecta Power distribution systems.