1SDX254825R1 ABB EPX-XT2N-E2-1603 160A 3P 36kA LSI Electronic Moulded Case Circuit Breaker

1SDX254825R1 ABB EPX-XT2N-E2-1603 160A 3P 36kA LSI Electronic Moulded Case Circuit Breaker

ABB EPX-XT2N-E2-1603 (1SDX254825R1) is a 160 A three-pole SACE Tmax XT2N160 moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and ABB Ekip LSI electronic protection. Designed for compatible ABB Protecta Power distribution assemblies, it provides long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection for three-phase outgoing circuits.

SKU: 1SDX254825R1Alt SKU: EPX-XT2N-E2-1603MPN: 1SDX254825R1
Price
List Price £1,412.80 ex VAT
Your Price (ex VAT)
£1,412.80
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,412.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,412.80

Why Choose the ABB EPX-XT2N-E2-1603 160A 3-Pole Electronic Moulded Case Circuit Breaker?

The ABB EPX-XT2N-E2-1603 is a high-performance 160 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT2N160 circuit breaker platform, this protective device combines compact construction with advanced electronic trip technology for commercial, industrial and building services applications.

Part of the ABB Protecta Power Devices product group, the EPX-XT2N-E2-1603 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its ABB Ekip LSI electronic trip configuration provides long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection. These three protection functions offer electrical engineers greater flexibility when coordinating circuit protection across a low-voltage distribution network.

With a 160 A rated current, a specified 36 kA short-circuit breaking capacity and a three-pole (3P) configuration, the EPX-XT2N-E2-1603 is suitable for appropriately designed three-phase outgoing feeders, commercial distribution boards, industrial electrical panels and building services installations. Its 90 mm nominal device width supports efficient use of space within compatible distribution assemblies.

Identified by ABB order code 1SDX254825R1, this electronic MCCB provides electrical contractors, consulting engineers, panel builders and facilities managers with a clearly specified solution for 160 A circuit protection where configurable electronic trip characteristics and dependable short-circuit performance are essential.

Key Advantages

  • 160 A rated current provides dependable protection for appropriately designed three-phase electrical distribution circuits.
  • 36 kA short-circuit breaking capacity in the specified ABB Protecta Power application.
  • Three-pole (3P) construction enables coordinated switching and protection of three phase conductors.
  • Electronic LSI trip protection combines long-time, short-time and instantaneous protection functions.
  • ABB Ekip electronic trip technology provides configurable protection characteristics for low-voltage distribution systems.
  • Long-time overload protection (L) helps safeguard cables and connected equipment against sustained excessive current.
  • Short-time delayed protection (S) supports coordination with downstream protective devices.
  • Instantaneous short-circuit protection (I) provides rapid operation under high fault-current conditions.
  • LSI protection functionality offers greater protection coordination flexibility than a conventional thermal-magnetic release.
  • Based on the established ABB SACE Tmax XT2N160 platform.
  • 160 A frame rating matches the rated current of this MCCB.
  • 90 mm nominal width supports compact and efficient distribution board layouts.
  • Designed for installation within compatible ABB Protecta Power distribution assemblies.
  • Suitable for commercial, industrial and building services electrical distribution applications.

Key Features

  • Manufacturer: ABB.
  • Product group: Protecta Power Devices.
  • Product designation: EPX-XT2N-E2-1603.
  • ABB order code: 1SDX254825R1.
  • Circuit breaker range: ABB SACE Tmax XT.
  • Circuit breaker platform: XT2N160.
  • Rated current: 160 A.
  • Frame rating: 160 A.
  • Specified short-circuit breaking capacity: 36 kA.
  • Number of poles: Three.
  • Trip configuration: ABB Ekip LSI electronic release.
  • Long-time protection (L): Protection against sustained overload conditions.
  • Short-time protection (S): Delayed short-circuit protection.
  • Instantaneous protection (I): Rapid short-circuit protection.
  • LSI protection arrangement: Long-time, short-time and instantaneous protection functions.
  • Electronic protection settings: Configurable according to the fitted release characteristics.
  • Nominal device width: 90 mm.
  • Neutral switching: No dedicated switched neutral pole.
  • Installation: Compatible ABB Protecta Power distribution assemblies.
  • Application: Three-phase commercial and industrial low-voltage electrical distribution.

Advanced 160A Electronic LSI Circuit Protection for Three-Phase Electrical Distribution

The ABB EPX-XT2N-E2-1603 160 A electronic MCCB is designed to help maintain the safety and reliability of low-voltage electrical distribution networks. Moulded case circuit breakers interrupt current when abnormal operating conditions occur, helping protect electrical cables, distribution equipment and connected loads against the damaging effects of overloads and short circuits.

Unlike a conventional thermal-magnetic circuit breaker, the EPX-XT2N-E2-1603 uses an electronic trip release to monitor current conditions and initiate tripping according to the selected protection characteristics. This provides electrical engineers with additional flexibility when coordinating protective devices across commercial and industrial distribution systems.

The ABB Ekip LSI electronic trip configuration provides three distinct protection functions. Long-time protection (L) responds to sustained overload conditions that could otherwise cause overheating of conductors and connected electrical equipment. Short-time protection (S) provides delayed short-circuit protection, allowing engineers to consider coordination with downstream protective devices. Instantaneous protection (I) provides rapid operation under high short-circuit current conditions.

The distinction between LSI and LS/I is important when specifying electronic MCCBs. An LSI release provides long-time, short-time and instantaneous protection functions within the same protection arrangement. An LS/I release provides long-time protection together with a choice between short-time and instantaneous short-circuit protection modes. The LSI configuration therefore offers additional flexibility for electrical installations requiring a coordinated protection strategy.

The three-pole construction enables coordinated protection and switching of the three phase conductors. This makes the EPX-XT2N-E2-1603 suitable for three-phase outgoing feeders, industrial distribution circuits and commercial electrical installations where a dedicated switched neutral pole is not required.

Built around the ABB SACE Tmax XT2N160 platform, the EPX-XT2N-E2-1603 combines a 160 A rated current with a specified 36 kA short-circuit breaking capacity. Its 90 mm nominal width helps engineers plan compact distribution board layouts while retaining the protection flexibility associated with electronic trip technology.

Correct circuit breaker selection should consider the installation operating voltage, prospective short-circuit current, conductor sizing, electronic trip settings, selectivity requirements and compatibility with the distribution assembly. The applicable breaking capacity and exact Ekip LSI adjustment ranges should be verified against the relevant ABB technical documentation before installation and commissioning.

Typical Applications

  • ABB Protecta Power distribution boards requiring 160 A three-pole electronic MCCB protection.
  • Commercial building electrical distribution and outgoing feeder circuits.
  • Industrial electrical panels supplying appropriately rated three-phase loads.
  • Three-phase sub-distribution systems requiring configurable electronic protection.
  • Building services installations supplying mechanical and electrical plant.
  • Manufacturing facilities and workshop electrical distribution networks.
  • Warehouses and logistics centres with three-phase electrical infrastructure.
  • Office buildings and retail premises with dedicated outgoing electrical feeders.
  • Distribution board refurbishment projects using compatible ABB Protecta Power equipment.
  • Switchboard manufacturing and panel-building projects requiring a 160 A, 3P, 36 kA electronic LSI MCCB.

Technical Specifications

Product group Protecta Power Devices
Product range SACE Tmax XT
Circuit breaker platform XT2N160
Model / SKU EPX-XT2N-E2-1603
ABB order code 1SDX254825R1
Product type Moulded case circuit breaker (MCCB)
Rated current 160 A
Frame rating 160 A
Short-circuit breaking capacity 36 kA (specified Protecta Power application)
Number of poles 3
Pole configuration Three-pole (3P)
Trip unit designation Ekip LSI
Trip technology Electronic
Protection designation LSI
Long-time protection (L) Overload protection
Short-time protection (S) Delayed short-circuit protection
Instantaneous protection (I) Instantaneous short-circuit protection
Protection arrangement Long-time, short-time and instantaneous overcurrent protection
Electronic trip adjustment Refer to the fitted ABB Ekip LSI release documentation
Neutral switching No dedicated switched neutral pole
Applicable circuit breaker standard IEC 60947-2
Nominal device width 90 mm
Installation type Fixed installation within a compatible distribution assembly
Mounting compatibility ABB Protecta Power, subject to appropriate mounting and connection arrangements
Electrical application Three-phase low-voltage power distribution
Typical use Outgoing feeder and sub-distribution circuit protection

Frequently Asked Questions

What is the ABB EPX-XT2N-E2-1603 used for?

The ABB EPX-XT2N-E2-1603 is a 160 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It features an ABB Ekip LSI electronic trip configuration and is intended for compatible ABB Protecta Power distribution assemblies.

What are the rated current and breaking capacity of the EPX-XT2N-E2-1603?

The EPX-XT2N-E2-1603 has a 160 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB SACE Tmax XT2N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be checked against the installation operating voltage and prospective fault current.

What does LSI mean on the ABB EPX-XT2N-E2-1603?

LSI stands for Long-time, Short-time and Instantaneous protection. Long-time protection responds to sustained overloads, short-time protection provides delayed short-circuit protection and instantaneous protection provides rapid operation under high fault-current conditions. These functions help engineers configure a coordinated circuit protection strategy.

What is the difference between an LSI MCCB and an LS/I MCCB?

An LSI MCCB provides long-time, short-time and instantaneous protection functions together. An LS/I MCCB provides long-time overload protection with a choice between short-time and instantaneous short-circuit protection modes. The LSI arrangement offers additional flexibility where both delayed and instantaneous short-circuit protection characteristics are required.

Where can the ABB EPX-XT2N-E2-1603 be installed?

The breaker is intended for installation within compatible ABB Protecta Power distribution boards, using the appropriate mounting and connection arrangements. The ABB XT2 three-pole platform has a nominal width of 90 mm. Installation and electronic trip configuration should be carried out by a competent electrical professional in accordance with the circuit design and applicable electrical regulations.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are established components in low-voltage electrical distribution, providing dependable protection for commercial and industrial installations. The ABB EPX-XT2N-E2-1603 combines a 160 A rated current, three-pole switching, specified 36 kA short-circuit breaking capacity and configurable ABB Ekip LSI electronic protection in a compact device intended for compatible ABB Protecta Power distribution systems.