1SDX254824R1 ABB EPX-XT2N-E2-1003 100A 3-Pole 36kA MCCB Ekip LSI

1SDX254824R1 ABB EPX-XT2N-E2-1003 100A 3-Pole 36kA MCCB Ekip LSI

ABB EPX-XT2N-E2-1003 is a 100 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and adjustable Ekip LSI electronic protection, designed for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX254824R1Alt SKU: EPX-XT2N-E2-1003MPN: 1SDX254824R1
Price
List Price £1,246.45 ex VAT
Your Price (ex VAT)
£1,246.45
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,246.45
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,246.45

Why Choose the ABB EPX-XT2N-E2-1003 100A 3-Pole Electronic MCCB?

The ABB EPX-XT2N-E2-1003 is a high-performance 100 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker combines a 36 kA short-circuit breaking capacity with advanced ABB Ekip LSI electronic protection, making it suitable for installations requiring adjustable circuit protection and effective fault management.

Based on the established ABB SACE Tmax XT2N platform, the EPX-XT2N-E2-1003 incorporates an electronic trip unit providing three important protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). This combination enables electrical designers to configure protective characteristics according to circuit requirements, conductor ratings and coordination objectives.

With a 100 A rated current, three-pole configuration and compact 100 mm device width, the ABB EPX-XT2N-E2-1003 offers a practical solution for outgoing three-phase circuits within compatible ABB Protecta Power distribution assemblies. Its electronic protection technology provides greater configuration flexibility than a conventional fixed-characteristic circuit breaker. The product is identified by ABB order code 1SDX254824R1.

Key Advantages

  • 100 A rated current for commercial and industrial low-voltage electrical distribution.
  • Three-pole (3P) configuration for coordinated protection and switching of three-phase circuits.
  • 36 kA short-circuit breaking capacity for installations with substantial prospective fault currents.
  • ABB Ekip LSI electronic trip unit provides configurable overload and short-circuit protection.
  • Long-time (L) protection helps safeguard conductors and equipment against sustained overload conditions.
  • Short-time delayed (S) protection supports selective coordination with downstream protective devices.
  • Instantaneous (I) protection provides rapid interruption during high-current short-circuit faults.
  • LSI protection functionality includes long-time, short-time and instantaneous protection within one electronic trip unit.
  • Adjustable protection settings provide flexibility for different electrical distribution applications.
  • Compact 100 mm three-pole width helps optimise installation space in compatible panelboards.
  • ABB SACE Tmax XT2N construction combines robust mechanical design with advanced electronic protection.
  • Part of the ABB Protecta Power Devices range, supporting integration into compatible ABB electrical distribution equipment.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT2N-E2-1003 product designation.
  • 100 A rated current for low-voltage circuit protection.
  • Three-pole (3P) construction for three-phase electrical distribution.
  • 36 kA short-circuit breaking capacity in the specified Protecta Power configuration.
  • ABB Ekip LSI electronic trip unit for configurable circuit protection.
  • L function: Adjustable long-time overload protection.
  • S function: Adjustable short-time delayed short-circuit protection.
  • I function: Adjustable instantaneous short-circuit protection.
  • LSI protection arrangement: Long-time, short-time and instantaneous protection functions included.
  • Electronic current sensing for controlled protective operation.
  • Configurable protection thresholds and operating characteristics to support circuit protection coordination.
  • ABB SACE Tmax XT2N platform with N breaking-capacity classification.
  • XT2 160 A frame family incorporating a 100 A electronic trip unit.
  • 100 mm three-pole device width for compact installation.
  • Manual switching mechanism with automatic electronic protective tripping.
  • Robust moulded case construction for commercial and industrial electrical environments.
  • Designed for integration into compatible ABB Protecta Power distribution assemblies.

Advanced LSI Electronic Protection for Three-Phase Power Distribution

The ABB EPX-XT2N-E2-1003 provides essential protection for low-voltage electrical distribution circuits where configurable protective operation is required. Its electronic trip unit monitors electrical current and initiates automatic circuit interruption when the configured protection thresholds are exceeded. This helps protect cables, distribution equipment and connected electrical infrastructure against excessive current and short-circuit faults.

The long-time (L) protection function responds to sustained overload conditions. Adjustable long-time protection characteristics enable the circuit breaker to be configured in accordance with the current-carrying capacity of conductors and the operating requirements of connected loads. Correctly selected settings help prevent excessive conductor heating while allowing normal electrical equipment operation within the circuit's design limits.

The short-time delayed (S) protection function provides additional flexibility for short-circuit protection coordination. In appropriately designed electrical distribution systems, a controlled short-time delay can allow a downstream protective device to clear a fault before an upstream breaker operates. This can help minimise unnecessary interruption to unaffected circuits. Actual discrimination and selectivity must be verified using the relevant ABB time-current curves and coordination data.

The instantaneous (I) protection function provides rapid operation when short-circuit current exceeds the selected threshold. This is particularly important for limiting the duration of high-current faults. The LSI configuration includes long-time, short-time and instantaneous protection functions together, offering greater flexibility than an LS/I arrangement in which short-time and instantaneous protection are alternative operating modes.

The ABB SACE Tmax XT2N platform combines compact dimensions with robust circuit protection technology. The EPX-XT2N-E2-1003 incorporates a 100 A electronic trip unit within the XT2 frame family and provides a 36 kA short-circuit breaking capacity. Its compact 100 mm three-pole width helps support efficient installation within compatible electrical distribution assemblies.

As part of the ABB Protecta Power range, this MCCB is intended for use with compatible panelboards and distribution equipment using the correct mounting and connection components. Electrical designers and installers should verify prospective fault current, operating voltage, conductor ratings, protection settings and coordination requirements before installation. Correct commissioning of the electronic trip unit is essential to achieving the intended protective performance.

Typical Applications

  • Commercial and industrial low-voltage electrical distribution systems.
  • ABB Protecta Power panelboards and compatible distribution assemblies.
  • Three-phase outgoing circuit protection.
  • Industrial switchboards and sub-distribution panels.
  • Manufacturing and production facilities.
  • Commercial offices and business premises.
  • Retail buildings and hospitality facilities.
  • Warehouses and logistics centres.
  • Building services and mechanical plant electrical distribution.
  • Distribution circuits requiring adjustable electronic overload protection.
  • Installations requiring coordinated short-time and instantaneous short-circuit protection.
  • Electrical infrastructure upgrades, maintenance and replacement projects.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power / SACE Tmax XT2N
ABB order code 1SDX254824R1
Corresponding ABB XT2N circuit breaker reference 1SDA067070R1
Product type Electronic moulded case circuit breaker (MCCB)
Rated current 100 A
Electronic trip unit rated current 100 A
Number of poles 3
Electrical configuration Three-phase
Short-circuit breaking capacity 36 kA
Protection technology Electronic
Trip unit designation ABB Ekip LSI
Long-time protection (L) Adjustable overload protection
Short-time protection (S) Adjustable delayed short-circuit protection
Instantaneous protection (I) Adjustable instantaneous short-circuit protection
Protection functions L, S and I
Frame family XT2
Frame current class 160 A
Frame performance designation N
Device width 100 mm
Corresponding breaker construction Fixed moulded case circuit breaker
Corresponding breaker terminal arrangement Front terminals
Operating mechanism Manual switching with automatic electronic protective tripping
Applicable circuit breaker standard IEC 60947-2
Mounting application Compatible electrical distribution assemblies
Application category Low-voltage electrical power distribution
Typical installation ABB Protecta Power panelboards and compatible distribution equipment

Frequently Asked Questions

What is the ABB EPX-XT2N-E2-1003 used for?

The ABB EPX-XT2N-E2-1003 is a three-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.

What is the rated current of the ABB EPX-XT2N-E2-1003?

The circuit breaker has a rated current of 100 A. It uses a 100 A ABB Ekip LSI electronic trip unit within the XT2 frame family, providing adjustable overload and short-circuit protection characteristics.

What is the breaking capacity of this MCCB?

The ABB EPX-XT2N-E2-1003 has a specified 36 kA short-circuit breaking capacity. Its suitability must be assessed against the installation's prospective fault current, operating voltage and applicable electrical protection requirements.

What does LSI mean on the ABB Ekip electronic trip unit?

LSI refers to three electronic protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). All three functions are included, allowing the protection characteristics to be configured for the electrical installation.

What is the difference between an LSI and an LS/I MCCB?

An LSI MCCB includes long-time, short-time delayed and instantaneous protection functions together. An LS/I MCCB provides long-time protection with a choice between short-time delayed or instantaneous short-circuit protection. The LSI configuration therefore offers greater flexibility for protection coordination where both short-time and instantaneous functions are required.

Trusted by Electrical Professionals Worldwide

ABB Protecta Power protective devices combine established circuit protection engineering with practical low-voltage distribution solutions. The EPX-XT2N-E2-1003 offers a compact 100 A, three-pole XT2N MCCB configuration with adjustable Ekip LSI electronic protection and a 36 kA breaking capacity, supporting dependable and configurable protection in commercial and industrial electrical installations.