ABB EPX-XT2N-E2-1003 is a 100 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and adjustable Ekip LSI electronic protection, designed for commercial and industrial low-voltage electrical distribution systems.
£1,246.45
The ABB EPX-XT2N-E2-1003 is a high-performance 100 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker combines a 36 kA short-circuit breaking capacity with advanced ABB Ekip LSI electronic protection, making it suitable for installations requiring adjustable circuit protection and effective fault management.
Based on the established ABB SACE Tmax XT2N platform, the EPX-XT2N-E2-1003 incorporates an electronic trip unit providing three important protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). This combination enables electrical designers to configure protective characteristics according to circuit requirements, conductor ratings and coordination objectives.
With a 100 A rated current, three-pole configuration and compact 100 mm device width, the ABB EPX-XT2N-E2-1003 offers a practical solution for outgoing three-phase circuits within compatible ABB Protecta Power distribution assemblies. Its electronic protection technology provides greater configuration flexibility than a conventional fixed-characteristic circuit breaker. The product is identified by ABB order code 1SDX254824R1.
The ABB EPX-XT2N-E2-1003 provides essential protection for low-voltage electrical distribution circuits where configurable protective operation is required. Its electronic trip unit monitors electrical current and initiates automatic circuit interruption when the configured protection thresholds are exceeded. This helps protect cables, distribution equipment and connected electrical infrastructure against excessive current and short-circuit faults.
The long-time (L) protection function responds to sustained overload conditions. Adjustable long-time protection characteristics enable the circuit breaker to be configured in accordance with the current-carrying capacity of conductors and the operating requirements of connected loads. Correctly selected settings help prevent excessive conductor heating while allowing normal electrical equipment operation within the circuit's design limits.
The short-time delayed (S) protection function provides additional flexibility for short-circuit protection coordination. In appropriately designed electrical distribution systems, a controlled short-time delay can allow a downstream protective device to clear a fault before an upstream breaker operates. This can help minimise unnecessary interruption to unaffected circuits. Actual discrimination and selectivity must be verified using the relevant ABB time-current curves and coordination data.
The instantaneous (I) protection function provides rapid operation when short-circuit current exceeds the selected threshold. This is particularly important for limiting the duration of high-current faults. The LSI configuration includes long-time, short-time and instantaneous protection functions together, offering greater flexibility than an LS/I arrangement in which short-time and instantaneous protection are alternative operating modes.
The ABB SACE Tmax XT2N platform combines compact dimensions with robust circuit protection technology. The EPX-XT2N-E2-1003 incorporates a 100 A electronic trip unit within the XT2 frame family and provides a 36 kA short-circuit breaking capacity. Its compact 100 mm three-pole width helps support efficient installation within compatible electrical distribution assemblies.
As part of the ABB Protecta Power range, this MCCB is intended for use with compatible panelboards and distribution equipment using the correct mounting and connection components. Electrical designers and installers should verify prospective fault current, operating voltage, conductor ratings, protection settings and coordination requirements before installation. Correct commissioning of the electronic trip unit is essential to achieving the intended protective performance.
| Product group | Protecta Power Devices |
|---|---|
| Series | Protecta Power / SACE Tmax XT2N |
| ABB order code | 1SDX254824R1 |
| Corresponding ABB XT2N circuit breaker reference | 1SDA067070R1 |
| Product type | Electronic moulded case circuit breaker (MCCB) |
| Rated current | 100 A |
| Electronic trip unit rated current | 100 A |
| Number of poles | 3 |
| Electrical configuration | Three-phase |
| Short-circuit breaking capacity | 36 kA |
| Protection technology | Electronic |
| Trip unit designation | ABB Ekip LSI |
| Long-time protection (L) | Adjustable overload protection |
| Short-time protection (S) | Adjustable delayed short-circuit protection |
| Instantaneous protection (I) | Adjustable instantaneous short-circuit protection |
| Protection functions | L, S and I |
| Frame family | XT2 |
| Frame current class | 160 A |
| Frame performance designation | N |
| Device width | 100 mm |
| Corresponding breaker construction | Fixed moulded case circuit breaker |
| Corresponding breaker terminal arrangement | Front terminals |
| Operating mechanism | Manual switching with automatic electronic protective tripping |
| Applicable circuit breaker standard | IEC 60947-2 |
| Mounting application | Compatible electrical distribution assemblies |
| Application category | Low-voltage electrical power distribution |
| Typical installation | ABB Protecta Power panelboards and compatible distribution equipment |
The ABB EPX-XT2N-E2-1003 is a three-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.
The circuit breaker has a rated current of 100 A. It uses a 100 A ABB Ekip LSI electronic trip unit within the XT2 frame family, providing adjustable overload and short-circuit protection characteristics.
The ABB EPX-XT2N-E2-1003 has a specified 36 kA short-circuit breaking capacity. Its suitability must be assessed against the installation's prospective fault current, operating voltage and applicable electrical protection requirements.
LSI refers to three electronic protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). All three functions are included, allowing the protection characteristics to be configured for the electrical installation.
An LSI MCCB includes long-time, short-time delayed and instantaneous protection functions together. An LS/I MCCB provides long-time protection with a choice between short-time delayed or instantaneous short-circuit protection. The LSI configuration therefore offers greater flexibility for protection coordination where both short-time and instantaneous functions are required.
ABB Protecta Power protective devices combine established circuit protection engineering with practical low-voltage distribution solutions. The EPX-XT2N-E2-1003 offers a compact 100 A, three-pole XT2N MCCB configuration with adjustable Ekip LSI electronic protection and a 36 kA breaking capacity, supporting dependable and configurable protection in commercial and industrial electrical installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.