1SDX254823R1 ABB EPX-XT2N-E2-0633 63A 3-Pole 36kA MCCB Ekip Dip LSI

1SDX254823R1 ABB EPX-XT2N-E2-0633 63A 3-Pole 36kA MCCB Ekip Dip LSI

ABB EPX-XT2N-E2-0633 is a 63 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and an adjustable Ekip Dip LSI electronic trip unit, designed for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX254823R1Alt SKU: EPX-XT2N-E2-0633MPN: 1SDX254823R1
Price
List Price £1,189.79 ex VAT
Your Price (ex VAT)
£1,189.79
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,189.79
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,189.79

Why Choose the ABB EPX-XT2N-E2-0633 63A 3-Pole Electronic MCCB?

The ABB EPX-XT2N-E2-0633 is a high-performance 63 A three-pole moulded case circuit breaker (MCCB) designed to protect commercial and industrial low-voltage electrical distribution systems against overloads and short circuits. Part of the ABB Protecta Power Devices range, this circuit breaker combines a 36 kA short-circuit breaking capacity with advanced Ekip Dip LSI electronic protection, providing a flexible solution for electrical installations requiring adjustable protection characteristics.

Built around the established ABB SACE Tmax XT2N platform, the EPX-XT2N-E2-0633 incorporates an electronic trip unit offering three distinct protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). Unlike an LS/I trip unit, which requires a choice between short-time and instantaneous protection, the LSI configuration includes all three protection functions, providing greater flexibility when coordinating circuit protection.

With its 63 A rated current, three-pole configuration and compact XT2 construction, this MCCB is particularly suitable for outgoing three-phase circuits within compatible ABB Protecta Power distribution assemblies. Its electronic protection technology makes it a practical choice for electrical contractors, panel builders, facilities engineers and industrial maintenance professionals. The product is identified by ABB order code 1SDX254823R1.

Key Advantages

  • 63 A rated current for commercial and industrial low-voltage distribution circuits.
  • Three-pole (3P) configuration for coordinated switching and protection of three-phase electrical circuits.
  • 36 kA short-circuit breaking capacity for installations with significant prospective fault currents.
  • Ekip Dip LSI electronic trip unit providing comprehensive overload and short-circuit protection.
  • Long-time (L) protection helps safeguard cables and connected equipment against sustained overload conditions.
  • Short-time delayed (S) protection supports selective coordination with downstream protective devices.
  • Instantaneous (I) protection provides rapid interruption during high-current short-circuit faults.
  • Independent L, S and I protection functions offer greater configuration flexibility than LS/I protection.
  • DIP-switch-adjustable protection settings allow the protective characteristics to be configured for the application.
  • Compact 100 mm three-pole width helps optimise space within compatible electrical distribution assemblies.
  • ABB SACE Tmax XT2N construction combines compact dimensions with dependable electrical protection.
  • Part of the ABB Protecta Power Devices range, supporting integration into compatible ABB distribution equipment.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT2N-E2-0633 product designation.
  • 63 A rated current for low-voltage circuit protection.
  • Three-pole (3P) construction for three-phase electrical distribution.
  • 36 kA short-circuit breaking capacity in the specified Protecta Power configuration.
  • ABB Ekip Dip LSI electronic trip unit.
  • L function: Adjustable long-time overload protection.
  • S function: Adjustable short-time delayed short-circuit protection.
  • I function: Adjustable instantaneous short-circuit protection.
  • LSI protection arrangement: All three protection characteristics are included.
  • Electronic current sensing for controlled protective operation.
  • DIP-switch configuration for adjustment of applicable protection thresholds and delays.
  • ABB SACE Tmax XT2N platform with N short-circuit performance classification.
  • XT2 160 A frame class incorporating a 63 A electronic trip unit.
  • 100 mm three-pole device width for compact installation.
  • 690 V AC maximum rated operational voltage for the corresponding XT2N breaker.
  • Manual switching mechanism with automatic electronic protective tripping.
  • Fixed circuit breaker construction with front terminals in the corresponding ABB XT2N configuration.
  • Designed for compatible ABB Protecta Power electrical distribution assemblies.

Advanced LSI Electronic Protection for Three-Phase Power Distribution

The ABB EPX-XT2N-E2-0633 provides dependable protection for low-voltage electrical distribution circuits where accurate and configurable protective operation is important. Its electronic trip unit monitors current conditions and initiates automatic interruption when the configured protection thresholds are exceeded. This helps protect cables, connected equipment and distribution infrastructure against excessive current and short-circuit faults.

The long-time (L) protection function responds to sustained overload conditions. By allowing the overload protection characteristics to be adjusted, the electronic trip unit supports coordination with the current-carrying capacity of cables and the operating requirements of connected equipment. Appropriate settings help reduce the risk of excessive conductor heating while allowing normal circuit operation within the installation's design limits.

The short-time delayed (S) protection function provides an additional level of flexibility for short-circuit protection. Where the electrical system has been designed for selective coordination, an appropriately configured short-time delay may allow a downstream protective device to clear a fault before an upstream circuit breaker operates. This can help limit the extent of an electrical interruption, although actual selectivity must be verified using the relevant ABB protection curves and coordination data.

The instantaneous (I) protection function provides rapid operation when short-circuit current exceeds the configured threshold. Unlike an LS/I configuration, which offers a choice between S and I protection, the Ekip Dip LSI trip unit includes long-time, short-time and instantaneous protection functions together. This makes the EPX-XT2N-E2-0633 particularly useful where adjustable protection coordination is required within a compact MCCB format.

The ABB SACE Tmax XT2N platform provides a compact and robust foundation for this electronic circuit breaker. The corresponding XT2N configuration has a 160 A frame class, while the EPX-XT2N-E2-0633 is equipped with a 63 A rated electronic trip unit. Its 36 kA breaking capacity at 415 V AC supports use in appropriately designed installations with substantial prospective fault currents.

As part of the ABB Protecta Power range, this MCCB is intended for installation in compatible electrical distribution assemblies using the appropriate mounting and connection components. Electrical designers and installers should confirm the installation's operating voltage, prospective fault current, cable ratings, protection settings and coordination requirements before selecting and commissioning the circuit breaker.

Typical Applications

  • Commercial and industrial low-voltage electrical distribution systems.
  • ABB Protecta Power panelboards and compatible distribution assemblies.
  • Three-phase outgoing circuit protection.
  • Industrial switchboards and sub-distribution panels.
  • Manufacturing and production facilities.
  • Commercial offices and business premises.
  • Retail buildings and hospitality facilities.
  • Warehouses and logistics centres.
  • Building services and mechanical plant electrical distribution.
  • Distribution circuits requiring adjustable electronic overload protection.
  • Installations requiring coordinated short-time and instantaneous fault protection.
  • Electrical infrastructure upgrades, maintenance and replacement projects.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power / SACE Tmax XT2N
ABB order code 1SDX254823R1
Corresponding ABB XT2N breaker reference 1SDA067069R1
Product type Electronic moulded case circuit breaker (MCCB)
Rated current 63 A
Electronic trip unit rated current 63 A
Number of poles 3
Electrical configuration Three-phase
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 415 V AC
Rated service short-circuit breaking capacity (Ics) 36 kA at 415 V AC
Rated operational voltage (Ue), corresponding breaker Up to 690 V AC
Rated insulation voltage (Ui), XT2N platform 1,000 V
Rated impulse withstand voltage (Uimp), XT2N platform 8 kV
Protection technology Electronic
Trip unit designation Ekip Dip LSI
Long-time protection (L) Adjustable overload protection
Short-time protection (S) Adjustable delayed short-circuit protection
Instantaneous protection (I) Adjustable instantaneous short-circuit protection
Protection adjustment method DIP switches
Protection functions L, S and I
Frame family XT2
Frame current class 160 A
Frame performance designation N
Device width 100 mm
Corresponding breaker construction Fixed moulded case circuit breaker
Corresponding breaker terminal arrangement Front terminals
Operating mechanism Manual switching with automatic electronic protective tripping
Applicable circuit breaker standard IEC 60947-2
Mounting application Compatible electrical distribution assemblies
Application category Low-voltage electrical power distribution
Typical installation ABB Protecta Power panelboards and compatible distribution equipment

Frequently Asked Questions

What is the ABB EPX-XT2N-E2-0633 used for?

The ABB EPX-XT2N-E2-0633 is a three-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.

What is the rated current of the ABB EPX-XT2N-E2-0633?

The circuit breaker has a rated current of 63 A. It uses a 63 A Ekip Dip LSI electronic trip unit within the ABB XT2N 160 A frame family, providing adjustable overload and short-circuit protection characteristics.

What is the breaking capacity of this MCCB?

The ABB EPX-XT2N-E2-0633 has a 36 kA rated ultimate short-circuit breaking capacity at 415 V AC. The corresponding XT2N configuration also provides a 36 kA rated service short-circuit breaking capacity at 415 V AC. Suitability must be checked against the prospective fault current and operating conditions of the installation.

What does LSI mean on the ABB Ekip Dip trip unit?

LSI refers to three electronic protection functions: long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). All three functions are included, allowing the protection characteristics to be configured for the electrical installation.

What is the difference between an LSI and an LS/I MCCB?

An LSI MCCB includes long-time, short-time delayed and instantaneous protection functions together. An LS/I MCCB provides long-time protection with a choice between short-time delayed or instantaneous short-circuit protection. The LSI configuration therefore offers greater flexibility for protection coordination where both short-time and instantaneous functions are required.

Trusted by Electrical Professionals Worldwide

ABB Protecta Power protective devices combine established electrical engineering with practical low-voltage distribution solutions. The EPX-XT2N-E2-0633 offers a compact 63 A, three-pole XT2N MCCB configuration with Ekip Dip LSI electronic protection and a 36 kA breaking capacity, supporting dependable and configurable circuit protection in commercial and industrial electrical installations.