1SDX254019R1 ABB EPX-XT5N-E1-6304 630A 4P 36kA MCCB - LS/I

1SDX254019R1 ABB EPX-XT5N-E1-6304 630A 4P 36kA MCCB – LS/I

ABB EPX-XT5N-E1-6304 is a 630 A four-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and an adjustable Ekip LS/I electronic trip unit, providing configurable overload and selectable delayed or instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX254019R1Alt SKU: EPX-XT5N-E1-6304MPN: 1SDX254019R1
Price
List Price £2,859.67 ex VAT
Your Price (ex VAT)
£2,859.67
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,859.67
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,859.67

Why Choose the ABB EPX-XT5N-E1-6304 630A 4-Pole MCCB?

The ABB EPX-XT5N-E1-6304 is a high-performance 630 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in demanding low-voltage electrical distribution systems. Featuring a 36 kA short-circuit breaking capacity and an advanced Ekip LS/I electronic trip unit, this circuit breaker belongs to the ABB Protecta Power Devices range and is based on ABB's established SACE Tmax XT5N platform.

Engineered for commercial and industrial installations, the EPX-XT5N-E1-6304 combines high-current circuit protection with configurable electronic trip characteristics. Its LS/I protection system provides long-time overload protection (L) together with a choice between short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). This flexibility helps electrical designers coordinate protective devices and configure circuit protection according to the installation's operating requirements.

With a 630 A rated current, four-pole configuration and 36 kA breaking capacity, the ABB EPX-XT5N-E1-6304 is particularly suitable for higher-current three-phase distribution circuits where four-pole switching is required. Supplied under ABB order code 1SDX254019R1, this electronic-trip MCCB offers a dependable solution for compatible ABB Protecta Power distribution assemblies, commercial switchgear and industrial electrical distribution panels.

Key Advantages

  • 630 A rated current provides protection for appropriately designed high-current electrical distribution circuits.
  • Four-pole (4P) configuration supports simultaneous switching of three phase conductors and a neutral conductor where applicable.
  • 36 kA short-circuit breaking capacity supports installations requiring substantial fault-current interruption capability.
  • Ekip LS/I electronic trip unit provides configurable overload and short-circuit protection.
  • Adjustable long-time overload protection (L) allows the protective threshold to be matched to conductor and circuit requirements.
  • Selectable short-time delayed (S) or instantaneous (I) protection supports different short-circuit protection strategies.
  • Electronic trip technology offers greater setting flexibility than conventional thermal-magnetic protection.
  • DIP-switch protection configuration provides practical adjustment of electronic trip settings.
  • ABB SACE Tmax XT5N construction combines high-current capability with a compact moulded case design.
  • Four-pole switching supports suitable three-phase and neutral distribution arrangements.
  • Designed for integration into compatible ABB Protecta Power distribution systems.
  • Suitable for commercial and industrial installations where protective device coordination is important.
  • Supports electrical distribution upgrades and compatible MCCB replacement applications.

Key Features

  • ABB Protecta Power Devices product group.
  • ABB SACE Tmax XT5N moulded case circuit breaker platform.
  • 630 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA short-circuit breaking capacity at 415 V AC.
  • Ekip Dip LS/I electronic protection release.
  • Long-time overload protection (L) with adjustable current threshold.
  • Short-time delayed short-circuit protection (S) available as a selectable protection mode.
  • Instantaneous short-circuit protection (I) available as an alternative selectable protection mode.
  • Long-time protection threshold adjustment: 0.4–1.0 × In.
  • Short-circuit protection threshold adjustment: 1–10 × In.
  • Electronic protection settings configured through front-accessible DIP switches.
  • Trip-unit status indications support commissioning and inspection.
  • XT5N 630 A frame with a 630 A electronic trip-unit rating.
  • Fixed-mounted circuit breaker platform for compatible electrical distribution assemblies.
  • Front-terminal connection arrangement on the corresponding ABB XT5N Ekip Dip LS/I breaker.
  • 190 mm nominal four-pole device width in the ABB Protecta Power XT5 range.
  • Manual toggle-operated switching mechanism.
  • Designed in accordance with IEC/EN 60947-2.
  • Designed for installation using compatible ABB Protecta Power mounting and connection accessories.
  • ABB manufacturer order code: 1SDX254019R1.

Advanced 630A Four-Pole Electronic Circuit Protection with Ekip LS/I Technology

The ABB EPX-XT5N-E1-6304 combines the mechanical switching and short-circuit interruption capabilities of an ABB SACE Tmax XT5N MCCB with the configurable protection functions of an Ekip Dip LS/I electronic trip unit. This arrangement allows the circuit breaker to respond to overload and short-circuit conditions according to selected protective thresholds and operating characteristics, helping protect cables, electrical equipment and distribution infrastructure.

The long-time protection function (L) provides adjustable overload protection. For the 630 A electronic release, the nominal adjustment range extends from 252 A to 630 A, corresponding to 0.4–1.0 × In. This allows the long-time protection threshold to be selected according to the installation's conductor ratings, operating current and protection coordination requirements. Actual settings must follow the manufacturer's available adjustment positions and the electrical design.

The LS/I designation identifies a protection arrangement in which long-time overload protection operates alongside a choice of short-circuit protection mode. The user can select either short-time delayed protection (S) or instantaneous protection (I). Unlike an LSI trip unit, the LS/I configuration does not provide separate S and I functions operating simultaneously. This distinction is important when designing discrimination between upstream and downstream protective devices.

The Ekip Dip LS/I protection platform offers a nominal short-circuit threshold adjustment range of 1–10 × In, corresponding to 630–6,300 A for the 630 A release. Selecting short-time delayed protection can support coordination with downstream devices where an intentional delay is appropriate, while instantaneous protection is intended to interrupt sufficiently high fault currents without an intentional short-time delay. The exact available settings and operating characteristics must be confirmed against the applicable ABB trip-unit documentation.

The four-pole construction makes this MCCB suitable for appropriately designed three-phase distribution systems where the neutral conductor must be switched alongside the phase conductors. The exact neutral-pole protection configuration must be verified against the manufacturer's documentation. Four-pole switching does not automatically provide residual-current or earth-leakage protection, and any required additional protective functions must be specified separately.

For installations using ABB Protecta Power distribution equipment, the XT5 platform provides a high-current MCCB solution with a 190 mm nominal four-pole width. ABB's Protecta Power guidance also recommends considering a side cableway extension box for XT5 outgoing devices where larger cables require additional installation space. Correct selection of cable terminations, mounting accessories and enclosure arrangements is essential.

The EPX-XT5N-E1-6304 offers a specified 36 kA breaking capacity at 415 V AC. Before installation, the circuit breaker's breaking capacity, trip settings and connection arrangement must be checked against the prospective fault current, operating voltage and relevant installation standards. This ensures that the selected MCCB is appropriate for the intended electrical distribution system.

Typical Applications

  • ABB Protecta Power distribution boards and compatible electrical assemblies.
  • Higher-current commercial low-voltage electrical distribution systems.
  • Industrial electrical distribution panels and switchgear.
  • Three-phase outgoing circuits requiring 630 A electronic overcurrent protection.
  • Four-pole distribution circuits requiring simultaneous phase and neutral switching.
  • Commercial building main and sub-distribution assemblies.
  • Manufacturing facilities and industrial electrical infrastructure.
  • Building services and mechanical plant power distribution.
  • Electrical installations requiring adjustable long-time overload protection.
  • Distribution systems where short-time delayed protection may support selective coordination.
  • Installations requiring a choice between delayed and instantaneous short-circuit protection.
  • Electrical refurbishment and distribution board upgrades involving compatible ABB MCCBs.

Technical Specifications

Product group Protecta Power Devices
Series SACE Tmax XT5 / Protecta Power
ABB order code 1SDX254019R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 630 A
Number of poles 4
Pole configuration 4P
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 415 V AC
Breaking capacity classification N (normal breaking capacity)
Trip unit type Ekip Dip LS/I electronic
Protection technology Electronic overcurrent release
Long-time protection (L) Adjustable overload protection
Long-time current threshold adjustment 0.4–1.0 × In
Nominal long-time threshold range 252–630 A
Long-time trip characteristic Inverse-time overload protection
Short-time protection (S) Selectable delayed short-circuit protection
Instantaneous protection (I) Selectable instantaneous short-circuit protection
S/I protection configuration Select either S or I short-circuit protection
Short-circuit threshold adjustment 1–10 × In
Nominal short-circuit threshold range 630–6,300 A
Protection adjustment method Front-mounted DIP switches
Trip-unit indications Electronic status and protection indications
Frame family XT5N
Frame rating 630 A
Nominal four-pole width 190 mm
Mounting configuration Fixed-mounted MCCB platform
Terminal configuration Front terminals on the corresponding XT5N configuration
Applicable circuit breaker standard IEC/EN 60947-2
Application Low-voltage electrical distribution
Installation type Compatible electrical distribution board / switchgear assembly
Operating mechanism Manual toggle-operated circuit breaker
Typical electrical system Three-phase AC distribution with four-pole switching

Frequently Asked Questions

What is the ABB EPX-XT5N-E1-6304 used for?

The ABB EPX-XT5N-E1-6304 is a 630 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an Ekip LS/I electronic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.

What is the rated current of the ABB EPX-XT5N-E1-6304?

The EPX-XT5N-E1-6304 has a 630 A rated current. Its electronic long-time overload protection can be adjusted below the rated current to suit the conductor ratings and operating requirements of appropriately designed electrical circuits.

What is the short-circuit breaking capacity of this MCCB?

The ABB EPX-XT5N-E1-6304 has a specified 36 kA short-circuit breaking capacity at 415 V AC. The prospective fault current and installation voltage must be checked before selecting the circuit breaker.

What does Ekip LS/I mean?

Ekip LS/I is an electronic trip unit providing long-time overload protection (L) together with a selectable short-circuit protection function. Either short-time delayed protection (S) or instantaneous protection (I) can be selected according to the requirements of the electrical installation.

What is the difference between Ekip LS/I and Ekip LSI?

An Ekip LS/I trip unit provides long-time protection with a choice between short-time delayed or instantaneous short-circuit protection. An Ekip LSI trip unit provides separate L, S and I protection functions for configuration. The two types should not be treated as interchangeable without reviewing the required protection characteristics.

Can the overload protection setting be adjusted?

Yes. The Ekip LS/I electronic trip unit provides an adjustable long-time overload threshold from 0.4 to 1.0 times the rated current. For this 630 A MCCB, the nominal adjustment range is 252–630 A, subject to the manufacturer's available settings.

Can the short-circuit protection be configured for delayed or instantaneous tripping?

Yes. The Ekip LS/I trip unit allows selection of either short-time delayed protection (S) or instantaneous protection (I). The nominal short-circuit threshold adjustment range is 1–10 × In, corresponding to 630–6,300 A for this 630 A device. The precise adjustment steps and time characteristics must be confirmed using the applicable ABB documentation.

What is the advantage of the four-pole configuration?

The four-pole (4P) configuration enables simultaneous switching of four conductors, typically the three phase conductors and a neutral conductor in a three-phase distribution system. This makes the MCCB suitable for installations requiring four-pole switching, subject to the manufacturer's neutral-pole arrangement and applicable electrical regulations.

Does the ABB EPX-XT5N-E1-6304 provide earth-leakage protection?

The standard Ekip LS/I electronic trip unit provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriate additional protective device or compatible solution must be specified.

What is the ABB order code for the EPX-XT5N-E1-6304?

The ABB manufacturer order code is 1SDX254019R1. The corresponding product reference is EPX-XT5N-E1-6304, identifying the 630 A, four-pole, 36 kA electronic-trip MCCB with Ekip LS/I protection within the ABB Protecta Power Devices range.

Trusted ABB Electronic Circuit Protection for Professional Installations

ABB Protecta Power circuit protection devices combine established SACE Tmax XT circuit breaker technology with configurable electronic protection. The EPX-XT5N-E1-6304 delivers dependable 630 A four-pole circuit protection, a 36 kA short-circuit breaking capacity and versatile Ekip LS/I functionality for appropriately specified commercial and industrial low-voltage electrical distribution systems.