Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT5N-E1-2504 is a 250 A four-pole moulded case circuit breaker from the Protecta Power Devices range, featuring a 36 kA breaking capacity at 415 V AC and Ekip Dip LS/I electronic overload and short-circuit protection for low-voltage electrical distribution systems.
£1,703.06
The ABB EPX-XT5N-E1-2504 is a high-performance 250 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the established ABB SACE Tmax XT5N400 platform, offering reliable electrical protection for commercial buildings, industrial facilities and electrical infrastructure.
Equipped with an ABB Ekip Dip LS/I electronic trip unit, the EPX-XT5N-E1-2504 provides long-time overload protection together with selectable short-time or instantaneous short-circuit protection. Its electronic protection technology enables configurable trip characteristics, supporting coordination between protective devices and helping safeguard electrical distribution cables, switchgear and connected equipment.
With a 250 A rated current, four-pole construction and 36 kA short-circuit breaking capacity, this MCCB is suitable for three-phase electrical distribution systems incorporating a neutral conductor. Its XT5N400 frame provides a robust solution for power distribution boards, switchboards and compatible ABB Protecta Power assemblies where electronic circuit protection and reliable fault interruption are essential.
Moulded case circuit breakers such as the ABB EPX-XT5N-E1-2504 protect electrical installations by automatically interrupting current when overload or short-circuit faults occur. The integrated Ekip Dip LS/I electronic trip unit provides long-time protection against sustained overload conditions and selectable short-time or instantaneous protection against short circuits. These protection functions help reduce the risk of damage to distribution cables, electrical equipment and connected circuits.
The ABB SACE Tmax XT5 circuit breaker family is developed for dependable performance in modern low-voltage distribution systems. Its robust construction, electronic protection technology and compatibility with suitable ABB accessories support integration into commercial and industrial electrical infrastructure. The EPX-XT5N-E1-2504 is particularly suited to installations requiring 250 A four-pole circuit protection and a 36 kA fault-breaking rating at 415 V AC, subject to verification of operating voltage, prospective fault current and protection coordination requirements.
| Product group | Protecta Power Devices |
|---|---|
| Product series | SACE Tmax XT |
| Frame designation | XT5N400 |
| ABB order code | 1SDX254016R1 |
| Corresponding ABB circuit breaker reference | 1SDA100394R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current (In) | 250 A |
| Number of poles | 4 |
| Rated ultimate short-circuit breaking capacity (Icu) | 36 kA at 415 V AC |
| Trip unit | Ekip Dip LS/I |
| Trip unit technology | Electronic |
| Long-time protection (L) | Adjustable overload protection |
| Short-time protection (S) | Short-circuit protection with intentional time delay |
| Instantaneous protection (I) | Short-circuit protection without intentional time delay |
| Protection configuration | Long-time protection with selectable short-time or instantaneous protection |
| Frame family | XT5N400 |
| Maximum frame rating | 400 A |
| Application | Low-voltage three-phase electrical distribution |
| Installation | Compatible electrical distribution boards and switchgear assemblies |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
The ABB EPX-XT5N-E1-2504 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial three-phase electrical distribution systems incorporating a neutral conductor.
The circuit breaker has a 250 A rated electronic trip unit current and uses the ABB Tmax XT5N400 frame, which has a maximum frame rating of 400 A. Its electronic protection settings can be configured according to the requirements of the electrical installation.
The EPX-XT5N-E1-2504 has a rated ultimate short-circuit breaking capacity of 36 kA at 415 V AC. The applicable breaking capacity must be checked against the installation voltage and prospective short-circuit current before selection.
The ABB Ekip Dip LS/I electronic trip unit provides long-time overload protection (L) together with selectable short-time short-circuit protection (S) or instantaneous short-circuit protection (I). These functions allow the protection response to be configured for suitable circuit coordination.
This MCCB is typically installed in low-voltage electrical distribution boards, industrial switchboards and compatible ABB Protecta Power assemblies, where four-pole electronic circuit protection is required. Appropriate installation accessories and cable termination arrangements should be selected according to the switchboard design.
ABB SACE Tmax XT moulded case circuit breakers are engineered to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT5N-E1-2504 combines a 250 A rating, four-pole construction and advanced Ekip Dip LS/I electronic protection in a robust circuit breaker suitable for commercial, industrial and infrastructure power distribution applications.
We use cookies