1SDX254013R1 ABB EPX-XT4N-E1-1604 160A 4-Pole 36kA Ekip LS/I Moulded Case Circuit Breaker

1SDX254013R1 ABB EPX-XT4N-E1-1604 160A 4-Pole 36kA Ekip LS/I Moulded Case Circuit Breaker

ABB EPX-XT4N-E1-1604 is a 160 A four-pole moulded case circuit breaker with 36 kA breaking capacity and an Ekip Dip LS/I electronic trip unit providing adjustable overload and selectable short-circuit protection for low-voltage electrical distribution.

SKU: 1SDX254013R1Alt SKU: EPX-XT4N-E1-1604MPN: 1SDX254013R1
Price
List Price £1,283.34 ex VAT
Your Price (ex VAT)
£1,283.34
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,283.34
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,283.34

Why Choose the ABB EPX-XT4N-E1-1604 160A 4-Pole MCCB?

The ABB EPX-XT4N-E1-1604 is a high-performance 160 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 36 kA breaking capacity and an Ekip Dip LS/I electronic trip unit, this circuit breaker delivers configurable protection for commercial, industrial and infrastructure electrical installations.

As part of the ABB Protecta Power Devices range, the EPX-XT4N-E1-1604 incorporates proven ABB SACE Tmax XT4N circuit breaker technology. Its electronic protection system provides adjustable long-time overload protection (L), together with selectable short-time delayed (S) or instantaneous (I) short-circuit protection. This enables electrical engineers to configure protection characteristics according to the requirements of the distribution system and connected equipment.

With a 160 A rated current, four-pole configuration and 36 kA short-circuit breaking capacity, the EPX-XT4N-E1-1604 is suitable for three-phase electrical distribution systems requiring dependable electronic circuit protection. Its compact XT4N frame, fixed-mounted construction and front terminals make it a practical solution for electrical panel builders, contractors and industrial maintenance engineers.

Key Advantages

  • 160 A rated current suitable for commercial and industrial low-voltage electrical distribution circuits.
  • 36 kA breaking capacity for dependable short-circuit protection.
  • Four-pole configuration suitable for three-phase and neutral distribution systems.
  • Ekip Dip LS/I electronic trip unit provides configurable electronic overload and short-circuit protection.
  • Adjustable long-time protection (L) helps protect electrical conductors and connected equipment against sustained overload currents.
  • Selectable short-time delayed (S) or instantaneous (I) protection supports different short-circuit protection requirements.
  • Electronic trip technology allows protection characteristics to be coordinated with the electrical installation.
  • ABB SACE Tmax XT4N technology combines robust construction with dependable circuit switching performance.
  • Compact fixed-mounted design supports efficient installation in electrical distribution assemblies.
  • Suitable for integration into ABB Protecta Power distribution boards and compatible switchgear arrangements.

Key Features

  • ABB EPX-XT4N-E1-1604 moulded case circuit breaker.
  • 160 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA short-circuit breaking capacity.
  • Ekip Dip LS/I electronic protection release.
  • Long-time overload protection (L) with adjustable protection characteristics.
  • Short-time delayed protection (S) for configurable short-circuit fault response.
  • Instantaneous protection (I) for rapid interruption of high short-circuit currents.
  • Selectable S or I protection mode within the electronic trip unit.
  • ABB SACE Tmax XT4N 160 configuration with a 160 A electronic trip rating.
  • XT4 frame with a maximum frame current rating of 250 A.
  • 690 V AC rated operational voltage for the underlying circuit breaker family.
  • Fixed installation with front connection terminals.
  • Manual operating mechanism for circuit switching.
  • Designed for low-voltage electrical distribution and circuit protection.
  • Compatible with appropriately selected ABB Tmax XT accessories and Protecta Power distribution equipment.

Advanced Electronic Circuit Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT4N-E1-1604 protect electrical distribution circuits against overload currents and short-circuit faults. The integrated Ekip Dip LS/I electronic trip unit provides adjustable long-time overload protection and selectable short-time delayed or instantaneous short-circuit protection. This flexibility allows electrical engineers to coordinate circuit breaker operation with the characteristics of electrical feeders, downstream protection devices and connected equipment.

The ABB SACE Tmax XT4N platform combines robust electrical protection with compact mechanical construction suitable for modern switchgear assemblies. With its 160 A rated current, four-pole switching arrangement and 36 kA breaking capacity, the EPX-XT4N-E1-1604 supports dependable protection of distribution feeders, switchboard circuits and industrial electrical installations. Its compatibility with ABB Protecta Power systems makes it particularly suitable for panel builders and electrical contractors requiring configurable electronic protection in low-voltage distribution equipment.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial and industrial low-voltage switchboards.
  • Three-phase electrical distribution systems requiring four-pole circuit protection.
  • Electrical distribution feeders and sub-distribution circuits.
  • Main and secondary distribution panels in commercial buildings.
  • Industrial machinery and equipment supply circuits.
  • Manufacturing facilities and production environments.
  • Warehouses, logistics facilities and industrial infrastructure.
  • Electrical panel building and switchgear assembly projects.
  • Power distribution systems requiring adjustable electronic overload protection.
  • Electrical installations requiring selectable delayed or instantaneous short-circuit protection.
  • Electrical installation upgrades, maintenance and refurbishment projects.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
Series XT4N
ABB order code 1SDX254013R1
ABB base circuit breaker reference 1SDA068146R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 160 A
Number of poles 4
Short-circuit breaking capacity 36 kA
Trip unit Ekip Dip LS/I electronic release
Release type Electronic
Long-time protection (L) Adjustable overload protection
Short-time protection (S) Short-circuit protection with adjustable delay
Instantaneous protection (I) Short-circuit protection without intentional delay
Short-circuit protection selection S or I
Frame size XT4
Frame designation XT4N 160
Maximum frame current rating 250 A
Breaking capacity class N
Rated operational voltage (Ue) Up to 690 V AC
Rated insulation voltage (Ui) 1,000 V
Rated impulse withstand voltage (Uimp) 8 kV
Mounting arrangement Fixed installation
Terminal arrangement Front terminals
Operating mechanism Manual toggle
Application Low-voltage electrical distribution and circuit protection
Applicable standard IEC 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4N-E1-1604 used for?

The ABB EPX-XT4N-E1-1604 is a 160 A four-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial, industrial and infrastructure installations.

What is the rated current of the EPX-XT4N-E1-1604?

The circuit breaker has a rated current of 160 A and uses an ABB SACE Tmax XT4N frame. Its electronic protection release is rated at 160 A, while the XT4 frame family supports configurations up to 250 A.

What is the breaking capacity of this ABB MCCB?

The EPX-XT4N-E1-1604 has a 36 kA short-circuit breaking capacity, making it suitable for appropriately designed low-voltage electrical distribution systems where the prospective fault current is within the applicable circuit breaker rating.

What does LS/I mean on the ABB EPX-XT4N-E1-1604?

LS/I identifies an electronic trip unit providing long-time overload protection (L) together with a choice between short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). The S and I functions are selectable alternatives rather than simultaneously active protection functions.

What is the difference between Ekip Dip LS/I and a thermal-magnetic trip unit?

The Ekip Dip LS/I electronic trip unit uses electronic protection technology to provide adjustable overload and short-circuit protection characteristics. A conventional thermal-magnetic trip unit uses thermal and magnetic elements to detect overcurrent conditions. Electronic protection offers greater flexibility when configuring trip characteristics for electrical distribution systems.

Does the ABB EPX-XT4N-E1-1604 provide adjustable protection?

Yes. The Ekip Dip LS/I electronic trip unit provides adjustable long-time overload protection and configurable short-circuit protection. Engineers can select the appropriate short-time delayed or instantaneous protection function according to the installation requirements and ABB's setting instructions.

Is the ABB EPX-XT4N-E1-1604 a four-pole circuit breaker?

Yes. The EPX-XT4N-E1-1604 is a four-pole (4P) MCCB designed for applications requiring four-pole switching and circuit protection in three-phase electrical distribution systems.

What ABB circuit breaker series does this model belong to?

The EPX-XT4N-E1-1604 uses ABB SACE Tmax XT4N circuit breaker technology and belongs to the ABB Protecta Power Devices product range. The corresponding ABB base circuit breaker reference is 1SDA068146R1.

What is the difference between LS/I and LSI protection?

An LS/I trip unit provides long-time overload protection with a selectable short-time delayed or instantaneous short-circuit protection function. An LSI trip unit provides long-time, short-time delayed and instantaneous protection functions together, allowing all three protection characteristics to be configured within the same release.

Where is the ABB EPX-XT4N-E1-1604 typically installed?

This MCCB is typically installed in low-voltage distribution boards, industrial switchboards and electrical panel assemblies, including compatible ABB Protecta Power distribution systems. Its fixed-mounted construction and front connection terminals support integration into suitable electrical enclosures.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely specified by electrical engineers, panel builders, industrial maintenance teams and electrical contractors for dependable overload and short-circuit protection. The ABB EPX-XT4N-E1-1604 combines a 160 A rated current, four-pole configuration and 36 kA breaking capacity with advanced Ekip Dip LS/I electronic protection, making it a practical choice for reliable low-voltage electrical distribution.