1SDX254012R1 ABB EPX-XT4N-E1-1004 100A 4-Pole 36kA Ekip LS/I Moulded Case Circuit Breaker

1SDX254012R1 ABB EPX-XT4N-E1-1004 100A 4-Pole 36kA Ekip LS/I Moulded Case Circuit Breaker

ABB EPX-XT4N-E1-1004 is a 100 A four-pole moulded case circuit breaker with 36 kA breaking capacity at 380–415 V AC and an Ekip Dip LS/I electronic trip unit providing adjustable overload and selectable short-circuit protection for low-voltage electrical distribution.

SKU: 1SDX254012R1Alt SKU: EPX-XT4N-E1-1004MPN: 1SDX254012R1
Price
List Price £1,252.74 ex VAT
Your Price (ex VAT)
£1,252.74
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,252.74
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,252.74

Why Choose the ABB EPX-XT4N-E1-1004 100A 4-Pole MCCB?

The ABB EPX-XT4N-E1-1004 is a reliable 100 A four-pole moulded case circuit breaker (MCCB) designed to provide advanced overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 36 kA breaking capacity and an Ekip Dip LS/I electronic trip unit, this circuit breaker delivers configurable protection for commercial, industrial and infrastructure electrical installations.

As part of the ABB Protecta Power Devices range, the EPX-XT4N-E1-1004 incorporates proven ABB SACE Tmax XT4N circuit breaker technology. Its electronic protection system provides long-time overload protection (L), together with a selectable short-time delayed (S) or instantaneous (I) short-circuit protection function. This allows electrical engineers to configure protection characteristics according to the requirements of the distribution system.

With a 100 A rated current, four-pole configuration and 36 kA short-circuit breaking capacity at 380–415 V AC, the EPX-XT4N-E1-1004 is suitable for three-phase electrical distribution systems requiring dependable electronic circuit protection. Its compact XT4N 160 frame and compatibility with ABB Protecta Power distribution equipment make it a practical choice for electrical panel builders, contractors and industrial maintenance engineers.

Key Advantages

  • 100 A rated current suitable for commercial and industrial low-voltage distribution circuits.
  • 36 kA breaking capacity at 380–415 V AC for dependable short-circuit protection.
  • Four-pole configuration suitable for three-phase and neutral distribution systems.
  • Ekip Dip LS/I electronic trip unit provides configurable electronic circuit protection.
  • Long-time overload protection (L) helps protect conductors and connected equipment against sustained overcurrent.
  • Selectable short-time (S) or instantaneous (I) protection supports different short-circuit protection requirements.
  • Electronic protection technology enables more flexible trip characteristic adjustment than conventional fixed thermal-magnetic protection.
  • ABB SACE Tmax XT4N technology combines robust construction with dependable switching performance.
  • Compact moulded case construction supports efficient installation in electrical distribution assemblies.
  • Suitable for integration into ABB Protecta Power distribution boards and compatible switchgear arrangements.

Key Features

  • ABB EPX-XT4N-E1-1004 moulded case circuit breaker.
  • 100 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA rated ultimate short-circuit breaking capacity (Icu) at 380–415 V AC.
  • Ekip Dip LS/I electronic protection release.
  • Long-time overload protection (L) with adjustable protection characteristics.
  • Short-time delayed protection (S) for configurable short-circuit fault response.
  • Instantaneous protection (I) for rapid interruption of high short-circuit currents.
  • Selectable S or I protection mode within the LS/I trip unit.
  • ABB SACE Tmax XT4N 160 frame with a 100 A electronic trip rating.
  • Electronic trip technology designed for low-voltage AC distribution systems.
  • Fixed-mounted circuit breaker construction with front connection terminals.
  • Manual operating mechanism for circuit switching.
  • Suitable for electrical distribution panels, switchboards and industrial power systems.
  • Compatible with appropriately selected ABB Tmax XT accessories and Protecta Power distribution equipment.

Advanced Electronic Circuit Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT4N-E1-1004 protect electrical distribution circuits against overload currents and short-circuit faults. Unlike conventional thermal-magnetic releases, the integrated Ekip Dip LS/I electronic trip unit uses electronic protection technology to provide adjustable long-time overload protection and selectable short-time delayed or instantaneous short-circuit protection. This flexibility allows engineers to coordinate circuit protection with the characteristics of electrical feeders, downstream devices and connected equipment.

The ABB SACE Tmax XT4N platform combines robust electrical protection with compact mechanical construction suitable for modern switchgear assemblies. With its 100 A rating, four-pole switching arrangement and 36 kA breaking capacity at 380–415 V AC, the EPX-XT4N-E1-1004 supports reliable protection of distribution feeders, switchboard circuits and industrial electrical installations. Its integration into ABB Protecta Power systems makes it particularly suitable for panel builders and electrical contractors requiring dependable electronic protection in low-voltage distribution equipment.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial and industrial low-voltage switchboards.
  • Three-phase electrical distribution systems requiring four-pole circuit protection.
  • Electrical distribution feeders and sub-distribution circuits.
  • Main and secondary distribution panels in commercial buildings.
  • Industrial machinery and equipment supply circuits.
  • Manufacturing facilities and production environments.
  • Warehouses, logistics facilities and industrial infrastructure.
  • Electrical panel building and switchgear assembly projects.
  • Power distribution systems requiring adjustable electronic overload protection.
  • Electrical installations requiring selectable delayed or instantaneous short-circuit protection.
  • Electrical installation upgrades, maintenance and refurbishment projects.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
Series XT4N
ABB order code 1SDX254012R1
ABB base circuit breaker reference 1SDA068145R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 100 A
Number of poles 4
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 380–415 V AC
Trip unit Ekip Dip LS/I electronic release
Protection technology Electronic overcurrent protection
Long-time protection (L) Adjustable overload protection
Short-time protection (S) Short-circuit protection with adjustable delay
Instantaneous protection (I) Short-circuit protection without intentional delay
Short-circuit protection selection S or I
Frame size XT4
Frame designation XT4N 160
Frame current rating 160 A
Breaking capacity class N
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1,000 V
Rated impulse withstand voltage (Uimp) 8 kV
Mounting arrangement Fixed installation
Terminal arrangement Front terminals
Operating mechanism Manual toggle
Application Low-voltage electrical distribution and circuit protection
Applicable standard IEC 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4N-E1-1004 used for?

The ABB EPX-XT4N-E1-1004 is a 100 A four-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.

What is the rated current of the EPX-XT4N-E1-1004?

The circuit breaker has a rated current of 100 A and uses an ABB XT4N 160 frame, making it suitable for appropriately designed electrical distribution circuits requiring a 100 A electronic protection release.

What is the breaking capacity of this ABB MCCB?

The EPX-XT4N-E1-1004 has a 36 kA rated ultimate short-circuit breaking capacity at 380–415 V AC. This represents its rated ability to interrupt prospective short-circuit currents under the specified test conditions.

What does LS/I mean on the ABB EPX-XT4N-E1-1004?

LS/I identifies an electronic trip unit providing long-time overload protection (L) together with a choice between short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I). The S and I functions are selectable alternatives rather than simultaneously active protection functions.

What is the difference between Ekip Dip LS/I and a thermal-magnetic trip unit?

The Ekip Dip LS/I uses electronic protection technology to provide adjustable overload and short-circuit protection characteristics. A conventional thermal-magnetic trip unit uses thermal and magnetic elements to detect overcurrent conditions. Electronic protection provides additional flexibility when configuring trip characteristics for electrical distribution systems.

Does the ABB EPX-XT4N-E1-1004 provide adjustable protection?

Yes. The Ekip Dip LS/I electronic trip unit provides adjustable long-time overload protection and configurable short-circuit protection. Engineers can select the appropriate short-time delayed or instantaneous protection function according to the installation requirements and the manufacturer's setting instructions.

Is the ABB EPX-XT4N-E1-1004 a four-pole circuit breaker?

Yes. The EPX-XT4N-E1-1004 is a four-pole (4P) MCCB designed for applications requiring four-pole switching and circuit protection in three-phase electrical distribution systems.

What ABB circuit breaker series does this model belong to?

The EPX-XT4N-E1-1004 uses ABB SACE Tmax XT4N circuit breaker technology and belongs to the ABB Protecta Power Devices range. The corresponding base circuit breaker reference is 1SDA068145R1.

What is the difference between LS/I and LSI protection?

An LS/I trip unit provides long-time protection with a selectable short-time delayed or instantaneous short-circuit function. An LSI trip unit provides long-time, short-time delayed and instantaneous protection functions together, allowing the three protection characteristics to be configured within the same release.

Where is the ABB EPX-XT4N-E1-1004 typically installed?

This MCCB is typically installed in low-voltage distribution boards, industrial switchboards and electrical panel assemblies, including compatible ABB Protecta Power distribution systems. Its fixed-mounted construction and front terminals support integration into suitable electrical enclosures.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely specified by electrical engineers, panel builders, industrial maintenance teams and electrical contractors for dependable overload and short-circuit protection. The ABB EPX-XT4N-E1-1004 combines a 100 A rating, four-pole configuration and 36 kA breaking capacity with advanced Ekip Dip LS/I electronic protection, making it a practical choice for reliable low-voltage electrical distribution.