1SDX254011R1 ABB EPX-XT4N-E1-0634 63A 4P 36kA LS/I Electronic Moulded Case Circuit Breaker

1SDX254011R1 ABB EPX-XT4N-E1-0634 63A 4P 36kA LS/I Electronic Moulded Case Circuit Breaker

ABB EPX-XT4N-E1-0634 (1SDX254011R1) is a 63 A four-pole SACE Tmax XT4N moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and ABB Ekip LS/I electronic protection. Designed for compatible ABB Protecta Power distribution assemblies, it provides configurable overload and short-circuit protection for three-phase outgoing circuits requiring four-pole switching.

SKU: 1SDX254011R1Alt SKU: EPX-XT4N-E1-0634MPN: 1SDX254011R1
Price
List Price £1,252.97 ex VAT
Your Price (ex VAT)
£1,252.97
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,252.97
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,252.97

Why Choose the ABB EPX-XT4N-E1-0634 63A 4-Pole Electronic Moulded Case Circuit Breaker?

The ABB EPX-XT4N-E1-0634 is a high-performance 63 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Built around the established ABB SACE Tmax XT4N circuit breaker platform, this protective device combines robust construction with electronic trip technology for commercial, industrial and building services applications.

As part of the ABB Protecta Power Devices product group, the EPX-XT4N-E1-0634 is designed for integration into compatible ABB Protecta Power distribution assemblies. Its ABB Ekip LS/I electronic trip configuration provides long-time overload protection together with selectable short-circuit protection characteristics, helping electrical engineers coordinate the protective device with the requirements of the installation.

With a 63 A rated current, a specified 36 kA short-circuit breaking capacity and a four-pole (4P) configuration, the EPX-XT4N-E1-0634 is suitable for appropriately designed three-phase outgoing circuits requiring coordinated switching of three phase conductors and a neutral conductor. Its 140 mm nominal device width supports efficient use of space within compatible distribution assemblies.

Identified by ABB order code 1SDX254011R1, this electronic MCCB provides electrical contractors, consulting engineers, panel builders and facilities managers with a clearly specified solution for 63 A four-pole circuit protection within the ABB Protecta Power range.

Key Advantages

  • 63 A rated current for dependable protection of appropriately designed low-voltage distribution circuits.
  • 36 kA short-circuit breaking capacity in the specified ABB Protecta Power application.
  • Four-pole (4P) construction supports coordinated switching of three phase conductors and a neutral conductor.
  • Electronic LS/I trip protection provides configurable overload and short-circuit protection characteristics.
  • ABB Ekip electronic trip technology offers protection setting flexibility compared with conventional thermal-magnetic releases.
  • Long-time overload protection (L) helps safeguard electrical cables and connected equipment against sustained excessive current.
  • Selectable short-time (S) or instantaneous (I) protection supports different short-circuit protection strategies.
  • Electronic trip adjustment supports coordination with appropriately rated conductors and connected electrical equipment.
  • Based on the established ABB SACE Tmax XT4N platform.
  • 140 mm nominal device width supports efficient distribution board layouts.
  • Four-pole switching capability supports installations where neutral disconnection is required.
  • Designed for installation within compatible ABB Protecta Power distribution assemblies.
  • Suitable for commercial, industrial and building services electrical distribution applications.

Key Features

  • Manufacturer: ABB.
  • Product group: Protecta Power Devices.
  • Product designation: EPX-XT4N-E1-0634.
  • ABB order code: 1SDX254011R1.
  • Circuit breaker range: ABB SACE Tmax XT.
  • Circuit breaker platform: XT4N.
  • Rated current: 63 A.
  • Specified short-circuit breaking capacity: 36 kA.
  • Number of poles: Four.
  • Trip configuration: ABB Ekip LS/I electronic release.
  • Long-time protection (L): Protection against sustained overload conditions.
  • Short-time protection (S): Delayed short-circuit protection when selected.
  • Instantaneous protection (I): Rapid short-circuit protection when selected.
  • LS/I arrangement: Long-time protection with a choice between short-time and instantaneous short-circuit characteristics.
  • Nominal device width: 140 mm.
  • Neutral switching: Four-pole construction for appropriate three-phase and neutral circuits.
  • Installation: Compatible ABB Protecta Power distribution assemblies.
  • Application: Commercial and industrial low-voltage electrical distribution.

Advanced 63A Four-Pole Electronic LS/I Protection for Electrical Distribution Systems

The ABB EPX-XT4N-E1-0634 63 A electronic MCCB is designed to help maintain the safety and reliability of low-voltage electrical distribution networks. Moulded case circuit breakers interrupt current when abnormal operating conditions occur, helping protect cables, distribution equipment and connected loads against the damaging effects of overloads and short circuits.

Unlike a conventional thermal-magnetic circuit breaker, the EPX-XT4N-E1-0634 uses an electronic trip release to evaluate current conditions and initiate tripping according to the selected protection characteristics. This makes it particularly useful in installations where engineers require greater flexibility when setting overload and short-circuit protection.

The ABB Ekip LS/I trip configuration provides long-time overload protection (L), which responds to sustained excessive current that could otherwise cause overheating of electrical conductors and equipment. The short-circuit protection arrangement allows the selection of either short-time delayed protection (S) or instantaneous protection (I), depending on the requirements of the protected circuit.

The distinction between LS/I and LSI is important when specifying electronic MCCBs. An LS/I release provides long-time overload protection with a choice between short-time and instantaneous short-circuit protection modes. An LSI release incorporates long-time, short-time and instantaneous protection characteristics together. Selecting the correct release helps engineers achieve the required protection strategy and coordination with other circuit breakers.

The four-pole construction supports coordinated switching of the three phase conductors and a neutral conductor. This is valuable in three-phase distribution systems where neutral disconnection forms part of the electrical design. However, neutral switching and neutral overcurrent protection are different functions. The precise neutral protection arrangement must be confirmed against the fitted release and applicable ABB documentation.

The ABB SACE Tmax XT4N platform provides a robust basis for low-voltage electrical protection. The EPX-XT4N-E1-0634 combines this construction with a 63 A rated current, a specified 36 kA breaking capacity and a 140 mm nominal width, making it a practical choice for compatible ABB Protecta Power distribution assemblies.

Correct selection should consider the system operating voltage, prospective short-circuit current, cable sizing, electronic trip settings, neutral switching requirements, discrimination and compatibility with the distribution assembly. The applicable breaking capacity and exact Ekip LS/I adjustment ranges should be verified against ABB technical documentation before installation and commissioning.

Typical Applications

  • ABB Protecta Power distribution boards requiring 63 A four-pole electronic MCCB protection.
  • Commercial building electrical distribution and outgoing feeder circuits.
  • Industrial electrical panels supplying appropriately rated three-phase loads.
  • Three-phase sub-distribution systems requiring neutral switching and electronic protection.
  • Building services installations supplying mechanical and electrical plant.
  • Manufacturing facilities and workshop electrical distribution networks.
  • Warehouses and logistics centres with three-phase electrical infrastructure.
  • Office buildings and retail premises with dedicated outgoing electrical circuits.
  • Distribution board refurbishment projects using compatible ABB Protecta Power equipment.
  • Switchboard manufacturing and panel-building projects requiring a 63 A, 4P, 36 kA electronic LS/I MCCB.

Technical Specifications

Product group Protecta Power Devices
Product range SACE Tmax XT
Circuit breaker platform XT4N
Model / SKU EPX-XT4N-E1-0634
ABB order code 1SDX254011R1
Product type Moulded case circuit breaker (MCCB)
Rated current 63 A
Short-circuit breaking capacity 36 kA (specified Protecta Power application)
Number of poles 4
Pole configuration Four-pole (4P)
Trip unit designation Ekip LS/I
Trip technology Electronic
Protection designation LS/I
Long-time protection (L) Overload protection
Short-time protection (S) Selectable delayed short-circuit protection
Instantaneous protection (I) Selectable instantaneous short-circuit protection
Protection arrangement Long-time overload protection with a choice between short-time and instantaneous short-circuit protection
Electronic trip adjustment Refer to the fitted ABB Ekip release documentation
Neutral switching Four-pole construction
Neutral protection Dependent on the fitted release and neutral pole arrangement
Applicable circuit breaker standard IEC 60947-2
Nominal device width 140 mm
Installation type Fixed installation within a compatible distribution assembly
Mounting compatibility ABB Protecta Power, subject to appropriate mounting and connection arrangements
Electrical application Three-phase low-voltage power distribution with four-pole switching
Typical use Outgoing feeder and sub-distribution circuit protection

Frequently Asked Questions

What is the ABB EPX-XT4N-E1-0634 used for?

The ABB EPX-XT4N-E1-0634 is a 63 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It features an ABB Ekip LS/I electronic trip configuration and is intended for compatible ABB Protecta Power distribution assemblies.

What are the rated current and breaking capacity of the EPX-XT4N-E1-0634?

The EPX-XT4N-E1-0634 has a 63 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB SACE Tmax XT4N platform. The applicable breaking capacity must be checked against the installation operating voltage and prospective fault current.

What does LS/I mean on the ABB EPX-XT4N-E1-0634?

LS/I identifies an electronic protection arrangement providing long-time overload protection (L) together with a choice of short-time delayed short-circuit protection (S) or instantaneous short-circuit protection (I). The selected protection mode and adjustment settings should be determined according to the electrical installation design and the manufacturer's instructions.

What is the advantage of the four-pole configuration?

The four-pole (4P) configuration enables coordinated switching of three phase conductors and a neutral conductor. This is useful in electrical distribution systems where neutral disconnection is required by the installation design. Neutral switching does not automatically establish the neutral overcurrent protection characteristics, which must be confirmed for the specific breaker configuration.

Where can the ABB EPX-XT4N-E1-0634 be installed?

The breaker is intended for installation within compatible ABB Protecta Power distribution boards, using the appropriate mounting and connection arrangements. The ABB XT4 four-pole platform has a nominal width of 140 mm. Installation and electronic trip configuration should be carried out by a competent electrical professional in accordance with the circuit design and applicable electrical regulations.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are established components in low-voltage electrical distribution, providing dependable protection for commercial and industrial installations. The ABB EPX-XT4N-E1-0634 combines a 63 A rated current, four-pole switching, specified 36 kA short-circuit breaking capacity and configurable ABB Ekip LS/I electronic protection in a robust device intended for compatible ABB Protecta Power distribution systems.