1SDX254010R1 ABB EPX-XT4N-E1-0404 40A 4P 36kA LS/I Electronic Moulded Case Circuit Breaker

1SDX254010R1 ABB EPX-XT4N-E1-0404 40A 4P 36kA LS/I Electronic Moulded Case Circuit Breaker

ABB EPX-XT4N-E1-0404 (1SDX254010R1) is a 40 A four-pole SACE Tmax XT4N moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and LS/I electronic protection. Designed for compatible ABB Protecta Power distribution assemblies, it provides configurable overload and short-circuit protection for three-phase outgoing circuits requiring four-pole switching.

SKU: 1SDX254010R1Alt SKU: EPX-XT4N-E1-0404MPN: 1SDX254010R1
Price
List Price £1,252.97 ex VAT
Your Price (ex VAT)
£1,252.97
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,252.97
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,252.97

Why Choose the ABB EPX-XT4N-E1-0404 40A 4-Pole Electronic Moulded Case Circuit Breaker?

The ABB EPX-XT4N-E1-0404 is a high-performance 40 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT4N circuit breaker platform, this protective device combines robust construction with electronic trip technology for commercial, industrial and building services applications.

As part of the ABB Protecta Power Devices product group, the EPX-XT4N-E1-0404 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its specified LS/I electronic trip configuration provides long-time overload protection together with selectable short-circuit protection characteristics, allowing electrical engineers to coordinate protection according to the requirements of the installation.

With a 40 A rated current, a specified 36 kA short-circuit breaking capacity and a four-pole (4P) configuration, the EPX-XT4N-E1-0404 is suitable for appropriately designed three-phase outgoing circuits requiring coordinated switching of three phase conductors and a neutral conductor. Its electronic protection technology offers an alternative to conventional thermal-magnetic MCCBs where additional flexibility in protection settings is required.

Identified by ABB order code 1SDX254010R1, this MCCB provides electrical contractors, consulting engineers, panel builders and facilities managers with a clearly specified solution for 40 A four-pole circuit protection within the ABB Protecta Power range.

Key Advantages

  • 40 A rated current for dependable protection of appropriately designed low-voltage distribution circuits.
  • 36 kA short-circuit breaking capacity in the specified ABB Protecta Power application.
  • Four-pole (4P) construction supports coordinated switching of three phase conductors and a neutral conductor.
  • Electronic LS/I trip protection provides configurable overload and short-circuit protection characteristics.
  • Long-time overload protection (L) helps safeguard electrical cables and connected equipment against sustained excessive current.
  • Selectable short-time (S) or instantaneous (I) protection supports different short-circuit protection strategies.
  • Electronic trip technology offers setting flexibility compared with conventional thermal-magnetic protection.
  • Based on the established ABB SACE Tmax XT4N platform.
  • XT4 frame construction provides a robust foundation for low-voltage circuit protection.
  • Four-pole switching capability supports installations where neutral disconnection is required.
  • Designed for installation within compatible ABB Protecta Power distribution assemblies.
  • Suitable for commercial, industrial and building services electrical distribution applications.
  • Suitable for new installations, electrical distribution upgrades and panel-building projects.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT4N-E1-0404 product designation.
  • ABB order code 1SDX254010R1.
  • ABB SACE Tmax XT4N circuit breaker platform.
  • 40 A rated current for outgoing circuit protection.
  • 36 kA specified short-circuit breaking capacity.
  • Four-pole (4P) configuration for coordinated switching of four conductors.
  • Electronic LS/I trip configuration for overload and short-circuit protection.
  • Long-time protection (L) against sustained overload conditions.
  • Short-time protection (S) for delayed short-circuit operation when selected.
  • Instantaneous protection (I) for rapid short-circuit operation when selected.
  • LS/I protection arrangement provides long-time protection with a choice of short-time or instantaneous short-circuit characteristics.
  • Electronic protection settings support coordination with appropriately rated cables and connected equipment.
  • Four-pole construction allows neutral switching where required by the installation design.
  • Manual operating mechanism for circuit switching and isolation when correctly installed.
  • Designed for installation using compatible ABB Protecta Power mounting and connection accessories.
  • Suitable for three-phase commercial and industrial low-voltage electrical distribution systems.

Advanced 40A Four-Pole Electronic LS/I Protection for Three-Phase Electrical Distribution

The ABB EPX-XT4N-E1-0404 40 A electronic MCCB is designed to help maintain the safety and reliability of low-voltage electrical distribution networks. Moulded case circuit breakers automatically interrupt current when abnormal operating conditions occur, helping protect electrical cables, distribution equipment and connected loads against the effects of overloads and short circuits.

The specified LS/I electronic trip configuration provides long-time overload protection (L), which responds to sustained excessive current that could otherwise cause overheating of conductors and electrical equipment. The short-circuit protection arrangement provides a choice between short-time delayed protection (S) and instantaneous protection (I), allowing the selected protection characteristics to suit the requirements of the electrical installation.

The distinction between LS/I and LSI is important when specifying an electronic MCCB. An LS/I release provides long-time overload protection with a choice between short-time and instantaneous short-circuit protection modes. An LSI release provides long-time, short-time and instantaneous protection functions together. The exact operating modes and available adjustment ranges should be confirmed against the documentation for the fitted electronic release.

The four-pole configuration is particularly useful in three-phase electrical distribution systems where the neutral conductor must be switched alongside the three phase conductors. This may be required in commercial distribution boards, industrial electrical installations and building services systems, depending on the earthing arrangement and electrical design. The presence of a fourth pole does not automatically establish the neutral overcurrent protection characteristics, which must be verified separately.

Built around the ABB SACE Tmax XT4N platform, the EPX-XT4N-E1-0404 combines a 40 A rated current with a specified 36 kA short-circuit breaking capacity. This combination makes it suitable for appropriately designed outgoing distribution circuits where the prospective short-circuit current falls within the applicable circuit breaker rating.

Correct circuit breaker selection should consider the system operating voltage, prospective short-circuit current, conductor sizing, electronic trip settings, neutral switching requirements, protective device coordination and compatibility with the electrical distribution assembly. The applicable breaking capacity, exact release characteristics and installation accessories should be verified against the relevant ABB technical documentation before installation and commissioning.

Typical Applications

  • ABB Protecta Power distribution boards requiring 40 A four-pole electronic MCCB protection.
  • Commercial building electrical distribution and outgoing feeder circuits.
  • Industrial electrical panels supplying appropriately rated three-phase loads.
  • Three-phase sub-distribution systems requiring neutral switching and configurable electronic protection.
  • Building services installations supplying mechanical and electrical plant.
  • Manufacturing facilities and workshop electrical distribution networks.
  • Warehouses and logistics centres with three-phase electrical infrastructure.
  • Office buildings and retail premises with dedicated outgoing electrical circuits.
  • Distribution board refurbishment projects using compatible ABB Protecta Power equipment.
  • Switchboard manufacturing and panel-building projects requiring a 40 A, 4P, 36 kA electronic LS/I MCCB.

Technical Specifications

Product group Protecta Power Devices
Product range SACE Tmax XT
Circuit breaker platform XT4N
Model / SKU EPX-XT4N-E1-0404
ABB order code 1SDX254010R1
Product type Moulded case circuit breaker (MCCB)
Rated current 40 A
Short-circuit breaking capacity 36 kA (specified Protecta Power application)
Number of poles 4
Pole configuration Four-pole (4P)
Trip unit designation LS/I
Trip technology Electronic
Long-time protection (L) Overload protection
Short-time protection (S) Selectable delayed short-circuit protection
Instantaneous protection (I) Selectable instantaneous short-circuit protection
Protection arrangement Long-time protection with selectable short-time or instantaneous short-circuit characteristics
Electronic trip adjustment Refer to the fitted ABB electronic release documentation
Neutral switching Four-pole construction
Neutral protection Dependent on the fitted release and neutral pole arrangement
Applicable circuit breaker standard IEC 60947-2
Installation type Fixed installation within a compatible distribution assembly
Mounting compatibility ABB Protecta Power, subject to appropriate mounting and connection arrangements
Electrical application Three-phase low-voltage power distribution with four-pole switching
Typical use Outgoing feeder and sub-distribution circuit protection

Frequently Asked Questions

What is the ABB EPX-XT4N-E1-0404 used for?

The ABB EPX-XT4N-E1-0404 is a 40 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It features an LS/I electronic trip configuration and is intended for compatible ABB Protecta Power distribution assemblies.

What are the rated current and breaking capacity of the EPX-XT4N-E1-0404?

The EPX-XT4N-E1-0404 has a 40 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB SACE Tmax XT4N platform. The applicable breaking capacity must be checked against the installation operating voltage and prospective fault current.

What does LS/I mean on the ABB EPX-XT4N-E1-0404?

LS/I identifies an electronic protection arrangement providing long-time overload protection (L) together with a choice of short-time delayed short-circuit protection (S) or instantaneous short-circuit protection (I). The selected protection mode and adjustment settings should be determined according to the electrical installation design and the manufacturer's instructions.

What is the advantage of the four-pole configuration?

The four-pole (4P) configuration enables coordinated switching of three phase conductors and a neutral conductor. This is useful in electrical distribution systems where neutral disconnection is required by the installation design. Neutral switching and neutral overcurrent protection are different functions, so the neutral protection characteristics must be confirmed for the specific breaker configuration.

Where can the ABB EPX-XT4N-E1-0404 be installed?

The breaker is intended for installation within compatible ABB Protecta Power distribution boards, using the appropriate mounting and connection arrangements. It is suitable for appropriately designed commercial, industrial and building services electrical distribution circuits. Installation and electronic trip configuration should be carried out by a competent electrical professional in accordance with the circuit design and applicable electrical regulations.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are established components in low-voltage electrical distribution, providing dependable protection for commercial and industrial installations. The ABB EPX-XT4N-E1-0404 combines a 40 A rated current, four-pole switching, specified 36 kA short-circuit breaking capacity and configurable LS/I electronic protection in a robust device intended for compatible ABB Protecta Power distribution systems.