ABB EPX-XT4N-E1-0404 (1SDX254010R1) is a 40 A four-pole SACE Tmax XT4N moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and LS/I electronic protection. Designed for compatible ABB Protecta Power distribution assemblies, it provides configurable overload and short-circuit protection for three-phase outgoing circuits requiring four-pole switching.
£1,252.97
The ABB EPX-XT4N-E1-0404 is a high-performance 40 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT4N circuit breaker platform, this protective device combines robust construction with electronic trip technology for commercial, industrial and building services applications.
As part of the ABB Protecta Power Devices product group, the EPX-XT4N-E1-0404 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its specified LS/I electronic trip configuration provides long-time overload protection together with selectable short-circuit protection characteristics, allowing electrical engineers to coordinate protection according to the requirements of the installation.
With a 40 A rated current, a specified 36 kA short-circuit breaking capacity and a four-pole (4P) configuration, the EPX-XT4N-E1-0404 is suitable for appropriately designed three-phase outgoing circuits requiring coordinated switching of three phase conductors and a neutral conductor. Its electronic protection technology offers an alternative to conventional thermal-magnetic MCCBs where additional flexibility in protection settings is required.
Identified by ABB order code 1SDX254010R1, this MCCB provides electrical contractors, consulting engineers, panel builders and facilities managers with a clearly specified solution for 40 A four-pole circuit protection within the ABB Protecta Power range.
The ABB EPX-XT4N-E1-0404 40 A electronic MCCB is designed to help maintain the safety and reliability of low-voltage electrical distribution networks. Moulded case circuit breakers automatically interrupt current when abnormal operating conditions occur, helping protect electrical cables, distribution equipment and connected loads against the effects of overloads and short circuits.
The specified LS/I electronic trip configuration provides long-time overload protection (L), which responds to sustained excessive current that could otherwise cause overheating of conductors and electrical equipment. The short-circuit protection arrangement provides a choice between short-time delayed protection (S) and instantaneous protection (I), allowing the selected protection characteristics to suit the requirements of the electrical installation.
The distinction between LS/I and LSI is important when specifying an electronic MCCB. An LS/I release provides long-time overload protection with a choice between short-time and instantaneous short-circuit protection modes. An LSI release provides long-time, short-time and instantaneous protection functions together. The exact operating modes and available adjustment ranges should be confirmed against the documentation for the fitted electronic release.
The four-pole configuration is particularly useful in three-phase electrical distribution systems where the neutral conductor must be switched alongside the three phase conductors. This may be required in commercial distribution boards, industrial electrical installations and building services systems, depending on the earthing arrangement and electrical design. The presence of a fourth pole does not automatically establish the neutral overcurrent protection characteristics, which must be verified separately.
Built around the ABB SACE Tmax XT4N platform, the EPX-XT4N-E1-0404 combines a 40 A rated current with a specified 36 kA short-circuit breaking capacity. This combination makes it suitable for appropriately designed outgoing distribution circuits where the prospective short-circuit current falls within the applicable circuit breaker rating.
Correct circuit breaker selection should consider the system operating voltage, prospective short-circuit current, conductor sizing, electronic trip settings, neutral switching requirements, protective device coordination and compatibility with the electrical distribution assembly. The applicable breaking capacity, exact release characteristics and installation accessories should be verified against the relevant ABB technical documentation before installation and commissioning.
| Product group | Protecta Power Devices |
|---|---|
| Product range | SACE Tmax XT |
| Circuit breaker platform | XT4N |
| Model / SKU | EPX-XT4N-E1-0404 |
| ABB order code | 1SDX254010R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 40 A |
| Short-circuit breaking capacity | 36 kA (specified Protecta Power application) |
| Number of poles | 4 |
| Pole configuration | Four-pole (4P) |
| Trip unit designation | LS/I |
| Trip technology | Electronic |
| Long-time protection (L) | Overload protection |
| Short-time protection (S) | Selectable delayed short-circuit protection |
| Instantaneous protection (I) | Selectable instantaneous short-circuit protection |
| Protection arrangement | Long-time protection with selectable short-time or instantaneous short-circuit characteristics |
| Electronic trip adjustment | Refer to the fitted ABB electronic release documentation |
| Neutral switching | Four-pole construction |
| Neutral protection | Dependent on the fitted release and neutral pole arrangement |
| Applicable circuit breaker standard | IEC 60947-2 |
| Installation type | Fixed installation within a compatible distribution assembly |
| Mounting compatibility | ABB Protecta Power, subject to appropriate mounting and connection arrangements |
| Electrical application | Three-phase low-voltage power distribution with four-pole switching |
| Typical use | Outgoing feeder and sub-distribution circuit protection |
The ABB EPX-XT4N-E1-0404 is a 40 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It features an LS/I electronic trip configuration and is intended for compatible ABB Protecta Power distribution assemblies.
The EPX-XT4N-E1-0404 has a 40 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB SACE Tmax XT4N platform. The applicable breaking capacity must be checked against the installation operating voltage and prospective fault current.
LS/I identifies an electronic protection arrangement providing long-time overload protection (L) together with a choice of short-time delayed short-circuit protection (S) or instantaneous short-circuit protection (I). The selected protection mode and adjustment settings should be determined according to the electrical installation design and the manufacturer's instructions.
The four-pole (4P) configuration enables coordinated switching of three phase conductors and a neutral conductor. This is useful in electrical distribution systems where neutral disconnection is required by the installation design. Neutral switching and neutral overcurrent protection are different functions, so the neutral protection characteristics must be confirmed for the specific breaker configuration.
The breaker is intended for installation within compatible ABB Protecta Power distribution boards, using the appropriate mounting and connection arrangements. It is suitable for appropriately designed commercial, industrial and building services electrical distribution circuits. Installation and electronic trip configuration should be carried out by a competent electrical professional in accordance with the circuit design and applicable electrical regulations.
ABB SACE Tmax XT moulded case circuit breakers are established components in low-voltage electrical distribution, providing dependable protection for commercial and industrial installations. The ABB EPX-XT4N-E1-0404 combines a 40 A rated current, four-pole switching, specified 36 kA short-circuit breaking capacity and configurable LS/I electronic protection in a robust device intended for compatible ABB Protecta Power distribution systems.