Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT2N-E1-1604 is a 160 A four-pole 36 kA electronic moulded case circuit breaker from the Protecta Power Devices range, featuring Ekip LS/I protection for adjustable overload and short-circuit protection in low-voltage electrical distribution systems.
£1,147.28
The ABB EPX-XT2N-E1-1604 is a compact and reliable 160 A four-pole moulded case circuit breaker (MCCB) designed to provide advanced overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the established ABB SACE Tmax XT2N circuit breaker platform, it combines electronic protection technology with space-efficient construction for commercial, industrial and building infrastructure applications.
This circuit breaker incorporates an ABB Ekip LS/I electronic trip unit, providing long-time overload protection together with selectable short-time delayed or instantaneous short-circuit protection. Its electronic trip technology enables adjustable protection characteristics, helping electrical engineers coordinate protective devices and improve the reliability of electrical distribution networks.
With a rated current of 160 A, a four-pole configuration and a 36 kA short-circuit breaking capacity at 415 V AC, the EPX-XT2N-E1-1604 is suitable for protecting three-phase outgoing feeders and distribution circuits incorporating a neutral conductor. Its compact 120 mm-wide XT2 frame enables straightforward integration into compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies.
Electronic moulded case circuit breakers such as the ABB EPX-XT2N-E1-1604 protect electrical installations by monitoring circuit current and automatically interrupting the supply when overload or short-circuit conditions exceed the configured protection thresholds. The Ekip LS/I electronic trip unit provides long-time overload protection together with a choice between short-time delayed and instantaneous short-circuit protection. This flexibility enables suitable protection characteristics to be selected according to the electrical installation and its coordination requirements.
The ABB SACE Tmax XT2N platform combines compact construction with electronic protection technology for modern low-voltage electrical distribution systems. Its four-pole arrangement supports coordinated switching of three phase conductors and a neutral conductor, while the corresponding fully rated neutral configuration provides protection suitable for systems requiring a 100% neutral rating. The compact 120 mm frame facilitates installation within compatible ABB Protecta Power distribution boards. Correct selection of protection settings, verification of prospective short-circuit current and coordination with other protective devices remain essential for safe and reliable operation.
| Product range | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT2 |
| ABB order code | 1SDX254008R1 |
| Corresponding ABB circuit breaker reference | 1SDA067095R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame designation | XT2N |
| Frame size | 160 A |
| Rated current (In) | 160 A |
| Number of poles | 4 |
| Rated ultimate short-circuit breaking capacity (Icu), XT2N series | 36 kA at 415 V AC |
| Rated service short-circuit breaking capacity (Ics), XT2N series | 36 kA at 415 V AC |
| Trip unit technology | Electronic |
| Trip unit series | ABB Ekip LS/I |
| Protection functions | Long-time overload (L) and selectable short-time (S) or instantaneous (I) short-circuit protection |
| Neutral rating, corresponding XT2N configuration | 100% of rated current |
| Rated operational voltage (Ue), XT2N series | Up to 690 V AC |
| Rated insulation voltage (Ui), XT2N series | 1000 V |
| Rated impulse withstand voltage (Uimp), XT2N series | 8 kV |
| Electrical system | Low-voltage three-phase AC distribution |
| Mounting arrangement | Fixed installation on the corresponding XT2N configuration |
| Terminal arrangement | Front terminals on the corresponding XT2N configuration |
| Nominal device width | 120 mm |
| Operating mechanism | Manual toggle operation |
| Application | Circuit protection, switching and isolation |
| Product family standard | IEC/EN 60947-2 |
The ABB EPX-XT2N-E1-1604 is a four-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial distribution boards, including compatible ABB Protecta Power assemblies.
The circuit breaker has a 160 A rated current and uses the ABB SACE Tmax XT2N 160 A frame. It is suitable for appropriately designed three-phase distribution circuits requiring electronic protection at this current rating.
The EPX-XT2N-E1-1604 is specified with a 36 kA short-circuit breaking capacity. The corresponding ABB XT2N electronic breaker platform has rated ultimate and service short-circuit breaking capacities of 36 kA at 415 V AC. The installation's prospective fault current must be considered when selecting the breaker.
Ekip LS/I identifies an electronic trip unit providing long-time overload protection (L) together with selectable short-time delayed (S) or instantaneous (I) short-circuit protection. The S and I functions are alternative protection modes, allowing the circuit breaker to be configured for the required protection characteristics.
The EPX-XT2N-E1-1604 has a four-pole configuration for switching three phase conductors and a neutral conductor. The corresponding ABB XT2N 160 A Ekip LS/I four-pole breaker configuration features a fully rated neutral, providing a neutral rating equal to 100% of the phase current.
An Ekip LS/I electronic MCCB uses electronic current monitoring and adjustable protection characteristics, while a conventional thermal-magnetic MCCB uses thermal and magnetic elements to respond to overloads and short circuits. Electronic protection provides additional flexibility when coordinating protective devices within electrical distribution systems.
Yes. The EPX-XT2N-E1-1604 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible low-voltage distribution assemblies. The appropriate XT2 mounting arrangement, electrical connections and enclosure compatibility should be verified before installation.
ABB SACE Tmax XT electronic moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining flexible electronic trip functionality, compact construction and dependable circuit protection for modern low-voltage power systems.