1SDX254008R1 ABB EPX-XT2N-E1-1604 160A 4-Pole 36kA Ekip LS/I Electronic MCCB

1SDX254008R1 ABB EPX-XT2N-E1-1604 160A 4-Pole 36kA Ekip LS/I Electronic MCCB

ABB EPX-XT2N-E1-1604 is a 160 A four-pole 36 kA electronic moulded case circuit breaker from the Protecta Power Devices range, featuring Ekip LS/I protection for adjustable overload and short-circuit protection in low-voltage electrical distribution systems.

SKU: 1SDX254008R1Alt SKU: EPX-XT2N-E1-1604MPN: 1SDX254008R1
Price
List Price £1,147.28 ex VAT
Your Price (ex VAT)
£1,147.28
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,147.28
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,147.28

Why Choose the ABB EPX-XT2N-E1-1604 160A 4-Pole MCCB?

The ABB EPX-XT2N-E1-1604 is a compact and reliable 160 A four-pole moulded case circuit breaker (MCCB) designed to provide advanced overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the established ABB SACE Tmax XT2N circuit breaker platform, it combines electronic protection technology with space-efficient construction for commercial, industrial and building infrastructure applications.

This circuit breaker incorporates an ABB Ekip LS/I electronic trip unit, providing long-time overload protection together with selectable short-time delayed or instantaneous short-circuit protection. Its electronic trip technology enables adjustable protection characteristics, helping electrical engineers coordinate protective devices and improve the reliability of electrical distribution networks.

With a rated current of 160 A, a four-pole configuration and a 36 kA short-circuit breaking capacity at 415 V AC, the EPX-XT2N-E1-1604 is suitable for protecting three-phase outgoing feeders and distribution circuits incorporating a neutral conductor. Its compact 120 mm-wide XT2 frame enables straightforward integration into compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies.

Key Advantages

  • Reliable 160 A electronic moulded case circuit breaker for low-voltage electrical distribution.
  • Four-pole configuration suitable for three-phase circuits incorporating a neutral conductor.
  • 36 kA breaking capacity at 415 V AC for protection against high prospective short-circuit currents.
  • Advanced ABB Ekip LS/I electronic trip unit for adjustable overload and short-circuit protection.
  • Long-time overload protection (L) helps protect cables and connected equipment against sustained excessive current.
  • Selectable short-time (S) or instantaneous (I) protection supports different short-circuit protection requirements.
  • Electronic protection settings facilitate coordination with upstream and downstream protective devices.
  • Fully rated neutral on the corresponding XT2N 160 A four-pole Ekip LS/I configuration.
  • Compact ABB Tmax XT2N frame with a nominal width of 120 mm.
  • Designed for integration into ABB Protecta Power distribution systems.
  • Four-pole switching supports electrical isolation and maintenance procedures.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB SACE Tmax XT2N moulded case circuit breaker platform.
  • 160 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA rated short-circuit breaking capacity at 415 V AC.
  • ABB Ekip LS/I electronic trip unit for overload and short-circuit protection.
  • L protection: Long-time overload protection.
  • S protection: Short-time delayed short-circuit protection, selectable as an alternative to instantaneous protection.
  • I protection: Instantaneous short-circuit protection, selectable as an alternative to short-time protection.
  • XT2N 160 A frame for low-voltage distribution applications.
  • 120 mm nominal width for compact four-pole installation.
  • 100% neutral rating on the corresponding ABB XT2N Ekip LS/I 160 A four-pole configuration.
  • Electronic protection technology supports adjustable trip characteristics.
  • Fixed mounting arrangement with front-terminal connections on the corresponding XT2N configuration.
  • Manual front-operated switching mechanism with circuit breaker trip indication.
  • Compatible with appropriately selected ABB Tmax XT2 mounting, connection and operating accessories.

Reliable Electronic Circuit Protection for Low-Voltage Distribution

Electronic moulded case circuit breakers such as the ABB EPX-XT2N-E1-1604 protect electrical installations by monitoring circuit current and automatically interrupting the supply when overload or short-circuit conditions exceed the configured protection thresholds. The Ekip LS/I electronic trip unit provides long-time overload protection together with a choice between short-time delayed and instantaneous short-circuit protection. This flexibility enables suitable protection characteristics to be selected according to the electrical installation and its coordination requirements.

The ABB SACE Tmax XT2N platform combines compact construction with electronic protection technology for modern low-voltage electrical distribution systems. Its four-pole arrangement supports coordinated switching of three phase conductors and a neutral conductor, while the corresponding fully rated neutral configuration provides protection suitable for systems requiring a 100% neutral rating. The compact 120 mm frame facilitates installation within compatible ABB Protecta Power distribution boards. Correct selection of protection settings, verification of prospective short-circuit current and coordination with other protective devices remain essential for safe and reliable operation.

Typical Applications

  • ABB Protecta Power distribution boards and panelboard assemblies.
  • Commercial building low-voltage electrical distribution.
  • Industrial electrical distribution panels and switchboards.
  • Three-phase circuits requiring four-pole switching and protection.
  • Outgoing feeder protection in main and sub-distribution boards.
  • Electrical control panels and industrial machinery supply circuits.
  • Building services, mechanical plant and infrastructure electrical systems.
  • Commercial premises, offices, warehouses and retail distribution installations.
  • Electrical networks requiring adjustable overload and short-circuit protection.
  • Low-voltage distribution systems requiring compact 160 A electronic MCCBs.

Technical Specifications

Product range Protecta Power Devices
Series SACE Tmax XT2
ABB order code 1SDX254008R1
Corresponding ABB circuit breaker reference 1SDA067095R1
Product type Moulded case circuit breaker (MCCB)
Frame designation XT2N
Frame size 160 A
Rated current (In) 160 A
Number of poles 4
Rated ultimate short-circuit breaking capacity (Icu), XT2N series 36 kA at 415 V AC
Rated service short-circuit breaking capacity (Ics), XT2N series 36 kA at 415 V AC
Trip unit technology Electronic
Trip unit series ABB Ekip LS/I
Protection functions Long-time overload (L) and selectable short-time (S) or instantaneous (I) short-circuit protection
Neutral rating, corresponding XT2N configuration 100% of rated current
Rated operational voltage (Ue), XT2N series Up to 690 V AC
Rated insulation voltage (Ui), XT2N series 1000 V
Rated impulse withstand voltage (Uimp), XT2N series 8 kV
Electrical system Low-voltage three-phase AC distribution
Mounting arrangement Fixed installation on the corresponding XT2N configuration
Terminal arrangement Front terminals on the corresponding XT2N configuration
Nominal device width 120 mm
Operating mechanism Manual toggle operation
Application Circuit protection, switching and isolation
Product family standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT2N-E1-1604 used for?

The ABB EPX-XT2N-E1-1604 is a four-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial distribution boards, including compatible ABB Protecta Power assemblies.

What is the rated current of the EPX-XT2N-E1-1604?

The circuit breaker has a 160 A rated current and uses the ABB SACE Tmax XT2N 160 A frame. It is suitable for appropriately designed three-phase distribution circuits requiring electronic protection at this current rating.

What is the breaking capacity of this ABB MCCB?

The EPX-XT2N-E1-1604 is specified with a 36 kA short-circuit breaking capacity. The corresponding ABB XT2N electronic breaker platform has rated ultimate and service short-circuit breaking capacities of 36 kA at 415 V AC. The installation's prospective fault current must be considered when selecting the breaker.

What does Ekip LS/I electronic protection mean?

Ekip LS/I identifies an electronic trip unit providing long-time overload protection (L) together with selectable short-time delayed (S) or instantaneous (I) short-circuit protection. The S and I functions are alternative protection modes, allowing the circuit breaker to be configured for the required protection characteristics.

Does the EPX-XT2N-E1-1604 provide four-pole protection?

The EPX-XT2N-E1-1604 has a four-pole configuration for switching three phase conductors and a neutral conductor. The corresponding ABB XT2N 160 A Ekip LS/I four-pole breaker configuration features a fully rated neutral, providing a neutral rating equal to 100% of the phase current.

What is the difference between an Ekip LS/I breaker and a thermal-magnetic MCCB?

An Ekip LS/I electronic MCCB uses electronic current monitoring and adjustable protection characteristics, while a conventional thermal-magnetic MCCB uses thermal and magnetic elements to respond to overloads and short circuits. Electronic protection provides additional flexibility when coordinating protective devices within electrical distribution systems.

Can the EPX-XT2N-E1-1604 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT2N-E1-1604 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible low-voltage distribution assemblies. The appropriate XT2 mounting arrangement, electrical connections and enclosure compatibility should be verified before installation.

Trusted by Electrical Engineers and Distribution Panel Builders

ABB SACE Tmax XT electronic moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining flexible electronic trip functionality, compact construction and dependable circuit protection for modern low-voltage power systems.