1SDX254006R1 ABB EPX-XT2N-E1-0634 63A 4P 36kA MCCB Ekip LS/I

1SDX254006R1 ABB EPX-XT2N-E1-0634 63A 4P 36kA MCCB Ekip LS/I

ABB EPX-XT2N-E1-0634 is a 63 A four-pole SACE Tmax XT2N160 moulded case circuit breaker with 36 kA breaking capacity and Ekip LS/I electronic overload and short-circuit protection for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX254006R1Alt SKU: EPX-XT2N-E1-0634MPN: 1SDX254006R1
Price
List Price £907.21 ex VAT
Your Price (ex VAT)
£907.21
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £907.21
Trade pricing is personalised to your account

Manufacturer Lead Time

£907.21

Why Choose the ABB EPX-XT2N-E1-0634 Protecta Power Circuit Breaker?

The ABB EPX-XT2N-E1-0634 is a high-performance 63 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the ABB SACE Tmax XT2N160 platform with an Ekip LS/I electronic trip unit, delivering configurable protection for compatible electrical distribution assemblies.

Featuring a 36 kA short-circuit breaking capacity, the EPX-XT2N-E1-0634 is designed to interrupt electrical faults while helping protect cables, switchgear and connected equipment. Its electronic trip unit provides long-time overload protection (L) together with a choice between short-time delayed (S) and instantaneous (I) short-circuit protection, supporting effective protective device coordination.

With a 63 A rated current, four-pole configuration and compact 120 mm nominal width, this MCCB is suitable for three-phase and neutral distribution circuits requiring four-pole switching. Its established ABB Tmax XT2N construction makes it a practical choice for electrical contractors, panel builders and maintenance engineers working with ABB Protecta Power distribution boards.

Key Advantages

  • 63 A rated current provides protection for appropriately designed low-voltage electrical distribution circuits.
  • Four-pole (4P) configuration supports simultaneous switching of three phase conductors and a neutral conductor where required.
  • 36 kA short-circuit breaking capacity provides protection against significant prospective electrical fault currents.
  • Ekip LS/I electronic trip unit delivers configurable overload and short-circuit protection.
  • Long-time overload protection (L) helps protect conductors and equipment against sustained excessive current.
  • Selectable short-time or instantaneous protection (S/I) supports coordination with downstream protective devices.
  • ABB SACE Tmax XT2N160 platform combines compact construction with electronic protection technology.
  • 120 mm nominal width helps optimise available space within compatible distribution boards.
  • Four-pole switching capability supports suitable three-phase and neutral distribution arrangements.
  • Designed for integration into compatible ABB Protecta Power electrical distribution assemblies.

Key Features

  • ABB Protecta Power Devices product family.
  • EPX-XT2N-E1-0634 model designation.
  • ABB SACE Tmax XT2N moulded case circuit breaker platform.
  • 63 A rated current.
  • XT2N160 frame with a maximum frame rating of 160 A.
  • Four-pole (4P) circuit breaker construction.
  • 36 kA short-circuit breaking capacity.
  • Ekip LS/I electronic trip unit.
  • L protection: Long-time overload protection.
  • S protection: Short-time delayed short-circuit protection, selectable as an alternative to I.
  • I protection: Instantaneous short-circuit protection, selectable as an alternative to S.
  • Electronic protection technology for defined protective characteristics.
  • Four-pole switching capability for compatible three-phase and neutral distribution systems.
  • Manual operating mechanism for circuit switching and resetting.
  • 120 mm nominal width for the four-pole XT2 configuration.
  • Suitable for low-voltage AC electrical distribution applications.
  • Compatible with appropriately selected ABB Tmax XT2 mounting, connection and operating accessories.

Advanced Ekip LS/I Electronic Protection for Four-Pole Distribution

The ABB EPX-XT2N-E1-0634 incorporates an Ekip LS/I electronic trip unit designed to protect electrical installations against overloads and short-circuit faults. Electronic protection technology uses current sensing and electronic processing to deliver defined protective characteristics, helping electrical designers achieve suitable protection coordination within low-voltage distribution systems.

The L (long-time) protection function responds to sustained excessive current, helping prevent overheating of electrical conductors and connected equipment. The S/I protection arrangement provides a choice between short-time delayed short-circuit protection and instantaneous short-circuit protection. Short-time delay can assist coordination with downstream protective devices, while instantaneous protection enables rapid interruption of high fault currents.

The four-pole construction supports installations where three phase conductors and a neutral conductor must be switched together. This arrangement is particularly useful in compatible three-phase and neutral distribution systems. The neutral pole's protection characteristics and suitability must be verified for the specific circuit breaker configuration and installation requirements.

The ABB SACE Tmax XT2N160 platform combines compact moulded case construction with electronic protection. Its 120 mm nominal four-pole width provides a space-efficient footprint for compatible distribution boards and switchboards.

When installing the EPX-XT2N-E1-0634 within an ABB Protecta Power distribution board, appropriate mounting components, terminal connections and protective covers must be selected. Electrical designers should verify prospective fault current, conductor ratings, neutral arrangements, electronic trip settings and protective device coordination before commissioning.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial low-voltage electrical distribution systems.
  • Industrial electrical switchboards and distribution panels.
  • 63 A four-pole outgoing feeder protection.
  • Three-phase and neutral distribution circuits.
  • Building services and mechanical plant distribution.
  • Commercial premises and office building electrical infrastructure.
  • Manufacturing and industrial facility electrical installations.
  • Commercial switchboards and sub-distribution assemblies.
  • Electrical panel building and switchboard manufacturing.
  • Distribution circuits requiring electronic overload and short-circuit protection.
  • Electrical installations where protective device coordination is important.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker series SACE Tmax XT
Circuit breaker frame XT2
Performance level XT2N
Frame configuration XT2N160
ABB order code 1SDX254006R1
Product type Moulded case circuit breaker (MCCB)
Rated current 63 A
Maximum frame rating 160 A
Number of poles 4P (four pole)
Short-circuit breaking capacity 36 kA
Trip unit Ekip LS/I
Trip technology Electronic
Overload protection L – long-time protection
Short-circuit protection S/I – selectable short-time delayed or instantaneous protection
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50/60 Hz
Nominal width 120 mm
Applicable standard IEC 60947-2
Installation type Electrical distribution board / switchboard mounting
Compatible system ABB Protecta Power
Product category Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT2N-E1-0634 used for?

The ABB EPX-XT2N-E1-0634 is a 63 A four-pole moulded case circuit breaker designed to protect commercial and industrial low-voltage electrical distribution circuits against overloads and short circuits using an Ekip LS/I electronic trip unit.

What is the rated current of the EPX-XT2N-E1-0634?

The EPX-XT2N-E1-0634 has a 63 A rated current and uses the ABB SACE Tmax XT2N160 platform, which has a maximum frame rating of 160 A. The frame rating does not change the specified 63 A rating of this device.

What is the breaking capacity of this circuit breaker?

The EPX-XT2N-E1-0634 is specified with a 36 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the operating voltage and prospective fault current of the electrical installation.

What does LS/I mean on the ABB EPX-XT2N-E1-0634?

LS/I identifies an electronic protection arrangement providing L (long-time overload protection) with a choice between S (short-time delayed short-circuit protection) and I (instantaneous short-circuit protection). The S and I functions are selectable alternatives rather than simultaneous independent functions.

What is the difference between Ekip LS/I and Ekip LSI?

Ekip LS/I provides long-time overload protection with a choice between short-time delayed and instantaneous short-circuit protection. Ekip LSI provides long-time, short-time delayed and instantaneous protection functions together, offering additional flexibility for protection coordination.

What is the difference between the EPX-XT2N-E1-0633 and EPX-XT2N-E1-0634?

Both circuit breakers use the ABB SACE Tmax XT2N160 platform and have a rated current of 63 A, a specified breaking capacity of 36 kA and Ekip LS/I electronic protection. The EPX-XT2N-E1-0633 has a three-pole configuration, while the EPX-XT2N-E1-0634 has a four-pole configuration for applications requiring four-pole switching.

What is the nominal width of the EPX-XT2N-E1-0634?

The ABB EPX-XT2N-E1-0634 uses the four-pole XT2 frame arrangement with a nominal width of 120 mm. Additional installation clearance may be required depending on the mounting arrangement, terminals and accessories.

Can the EPX-XT2N-E1-0634 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT2N-E1-0634 belongs to the ABB Protecta Power Devices range and is intended for compatible electrical distribution assemblies. Appropriate XT2 mounting components, terminal connections, covers and installation accessories must be selected according to the switchboard configuration.

Trusted ABB Electronic Circuit Protection for Electrical Distribution

ABB SACE Tmax XT moulded case circuit breakers provide dependable overload and short-circuit protection for commercial and industrial electrical installations. The EPX-XT2N-E1-0634 combines a 63 A four-pole XT2N160 circuit breaker with 36 kA breaking capacity and Ekip LS/I electronic protection, delivering a compact and configurable solution for compatible ABB Protecta Power distribution assemblies.