1SDX253996R1 ABB EPX-XT5N-E1-6303 630A 3-Pole 36kA MCCB Ekip Dip LS/I

1SDX253996R1 ABB EPX-XT5N-E1-6303 630A 3-Pole 36kA MCCB Ekip Dip LS/I

ABB EPX-XT5N-E1-6303 is a 630 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and an adjustable Ekip Dip LS/I electronic trip unit, designed for high-current commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX253996R1Alt SKU: EPX-XT5N-E1-6303MPN: 1SDX253996R1
Price
List Price £2,182.25 ex VAT
Your Price (ex VAT)
£2,182.25
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,182.25
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,182.25

Why Choose the ABB EPX-XT5N-E1-6303 630A 3-Pole Electronic MCCB?

The ABB EPX-XT5N-E1-6303 is a high-performance 630 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in demanding commercial and industrial electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker combines a 36 kA short-circuit breaking capacity at 415 V AC with advanced Ekip Dip LS/I electronic protection for high-current low-voltage installations.

Built around the ABB SACE Tmax XT5N 630 platform, the EPX-XT5N-E1-6303 incorporates an electronic trip unit rather than a conventional thermal-magnetic release. Its Ekip Dip LS/I trip unit provides long-time overload protection together with selectable short-time delayed or instantaneous short-circuit protection. Adjustable electronic protection characteristics help electrical designers coordinate the circuit breaker with cables, connected loads and downstream protective devices.

With a 630 A rated current, three-pole configuration and 36 kA ultimate and service short-circuit breaking capacities at 415 V AC, the ABB EPX-XT5N-E1-6303 is suitable for appropriately designed high-current three-phase feeders, industrial switchboards and electrical distribution assemblies. Identified by ABB order code 1SDX253996R1, this MCCB belongs to the Protecta Power range and is intended for integration into compatible ABB distribution equipment.

Key Advantages

  • 630 A rated current for high-capacity commercial and industrial electrical distribution circuits.
  • Three-pole (3P) configuration for coordinated protection and switching of three-phase circuits.
  • 36 kA ultimate short-circuit breaking capacity at 415 V AC for installations with substantial prospective fault currents.
  • 36 kA service short-circuit breaking capacity at 415 V AC, equal to 100% of Icu at this voltage.
  • ABB Ekip Dip LS/I electronic trip unit provides configurable overload and short-circuit protection.
  • Long-time (L) protection helps protect cables and connected equipment against sustained overload conditions.
  • Selectable short-time (S) or instantaneous (I) protection supports different short-circuit protection strategies.
  • DIP-switch configuration enables adjustment of electronic protection settings.
  • Electronic current sensing provides precise, configurable protective operation.
  • Robust ABB SACE Tmax XT5N 630 frame designed for demanding low-voltage distribution applications.
  • 690 V AC rated operational voltage for the corresponding XT5N circuit breaker platform.
  • Suitable for integration into compatible ABB Protecta Power panelboards and distribution assemblies.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT5N-E1-6303 product designation.
  • 630 A rated current for high-capacity electrical circuit protection.
  • Three-pole (3P) construction for three-phase power distribution.
  • 36 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • 36 kA rated service short-circuit breaking capacity at 415 V AC.
  • Ekip Dip LS/I electronic trip unit for adjustable circuit protection.
  • L protection: Long-time overload protection with configurable current pickup and operating delay.
  • S protection: Selectable short-time delayed short-circuit protection.
  • I protection: Selectable instantaneous short-circuit protection.
  • LS/I protection arrangement: Long-time protection combined with a choice of short-time delayed or instantaneous short-circuit protection.
  • DIP-switch adjustment for setting protection parameters.
  • ABB SACE Tmax XT5N platform with N short-circuit performance classification.
  • XT5 630 A frame configuration for substantial distribution currents.
  • 1,000 V rated insulation voltage for the corresponding XT5N breaker.
  • 8 kV rated impulse withstand voltage for the corresponding XT5N breaker.
  • Manual switching mechanism with automatic electronic protective tripping.
  • Robust moulded case construction suitable for commercial and industrial installations.
  • Designed for integration into compatible ABB Protecta Power distribution assemblies.

Advanced Electronic Protection for High-Current Power Distribution

The ABB EPX-XT5N-E1-6303 provides essential protection for high-current low-voltage electrical distribution circuits. Its electronic trip unit monitors electrical current and initiates automatic circuit interruption when configured protective thresholds are exceeded. This helps protect cables, switchgear and connected electrical equipment against excessive current and short-circuit faults.

The Ekip Dip LS/I electronic trip unit provides configurable protection characteristics for demanding distribution applications. Its long-time (L) function responds to sustained overloads using an adjustable current pickup and operating delay. This enables the overload protection to be coordinated with appropriately rated conductors, connected loads and other protective devices in the installation.

The LS/I designation identifies a trip unit that combines long-time overload protection with a choice between short-time delayed (S) and instantaneous (I) short-circuit protection. Short-time protection can introduce a controlled delay to support selectivity with downstream protective devices, while instantaneous protection provides rapid interruption when its selected current threshold is exceeded. Unlike an LSI trip unit, the LS/I configuration uses S and I as alternative short-circuit protection modes rather than independently active functions operating simultaneously.

The ABB SACE Tmax XT5N 630 platform is designed for demanding low-voltage power distribution duties. The corresponding breaker provides a 630 A current rating, 36 kA ultimate short-circuit breaking capacity at 415 V AC and 36 kA service short-circuit breaking capacity at the same voltage. Its electronic protection system and substantial current capacity make it suitable for appropriately designed high-current feeders and industrial distribution circuits.

As part of the ABB Protecta Power range, the EPX-XT5N-E1-6303 is intended for integration into compatible panelboards and distribution assemblies using the correct mounting and connection components. Electrical designers and installers should verify the prospective fault current, operating voltage, cable ratings, electronic protection settings and coordination requirements before installation. Adequate connection space, conductor capacity and thermal management should also be considered for high-current distribution applications.

Typical Applications

  • Commercial and industrial low-voltage electrical distribution systems.
  • ABB Protecta Power panelboards and compatible assemblies.
  • High-current three-phase outgoing feeder protection.
  • Industrial switchboards and distribution panels.
  • Manufacturing and production facilities.
  • Large commercial buildings and office complexes.
  • Warehouses, logistics centres and distribution facilities.
  • Building services and mechanical plant electrical distribution.
  • Electrical sub-distribution and high-capacity feeder circuits.
  • Installations requiring adjustable electronic overload protection.
  • Distribution circuits requiring selectable delayed or instantaneous short-circuit protection.
  • Electrical infrastructure upgrades, maintenance and replacement projects.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power / SACE Tmax XT5N
ABB order code 1SDX253996R1
Corresponding ABB XT5N circuit breaker reference 1SDA100355R1
Product type Electronic moulded case circuit breaker (MCCB)
Rated current 630 A
Rated uninterrupted current (Iu) 630 A
Number of poles 3
Electrical configuration Three-phase
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 415 V AC
Rated service short-circuit breaking capacity (Ics) 36 kA at 415 V AC
Rated operational voltage (Ue), corresponding breaker Up to 690 V AC
Rated insulation voltage (Ui) 1,000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated short-time withstand current (Icw) 6 kA
Current type AC
Protection technology Electronic
Trip unit ABB Ekip Dip LS/I
Rated trip unit current 630 A
Long-time protection (L) Adjustable overload protection
Short-time protection (S) Selectable delayed short-circuit protection
Instantaneous protection (I) Selectable instantaneous short-circuit protection
Short-circuit protection selection S or I
Protection adjustment method DIP switches
Protection functions Long-time overload protection with selectable short-time delayed or instantaneous short-circuit protection
Frame family XT5
Frame current class 630 A
Frame performance designation N
Corresponding breaker construction Fixed moulded case circuit breaker
Corresponding breaker terminal arrangement Front terminals
Corresponding breaker electrical durability 5,000 operating cycles
Corresponding breaker mechanical durability 20,000 operating cycles
Corresponding breaker power loss 45 W
Operating mechanism Manual switching with automatic electronic protective tripping
Applicable circuit breaker standard IEC 60947-2
Mounting application Compatible electrical distribution assemblies
Application category Low-voltage electrical power distribution
Typical installation ABB Protecta Power panelboards and compatible distribution equipment

Frequently Asked Questions

What is the ABB EPX-XT5N-E1-6303 used for?

The ABB EPX-XT5N-E1-6303 is a three-pole electronic moulded case circuit breaker designed to protect high-current low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.

What is the rated current of the ABB EPX-XT5N-E1-6303?

The circuit breaker has a rated current of 630 A. Its Ekip Dip LS/I electronic trip unit provides adjustable long-time overload protection, allowing the protection settings to be coordinated with appropriately designed electrical circuits and connected loads.

What is the breaking capacity of this MCCB?

The ABB EPX-XT5N-E1-6303 has a 36 kA rated ultimate short-circuit breaking capacity at 415 V AC. The corresponding XT5N 630 breaker also provides a 36 kA rated service short-circuit breaking capacity at 415 V AC. Suitability must be assessed against the prospective fault current and operating conditions of the installation.

What does LS/I mean on the ABB Ekip Dip trip unit?

LS/I means the electronic trip unit provides long-time overload protection (L) together with a selectable short-circuit protection function: either short-time delayed protection (S) or instantaneous protection (I). The S and I functions are alternatives rather than independently active functions operating simultaneously, distinguishing LS/I from an LSI trip unit.

What is the difference between an electronic LS/I MCCB and a thermal-magnetic MCCB?

An electronic LS/I MCCB uses an electronic trip unit with adjustable overload and selectable delayed or instantaneous short-circuit protection characteristics. A conventional thermal-magnetic MCCB uses thermal and magnetic elements to detect overloads and short circuits. The electronic LS/I design offers additional flexibility for setting protective thresholds and coordinating circuit protection in appropriately designed distribution systems.

Trusted by Electrical Professionals Worldwide

ABB Protecta Power circuit protection devices combine established electrical engineering with practical low-voltage distribution solutions. The EPX-XT5N-E1-6303 offers a robust 630 A, three-pole XT5N MCCB configuration with Ekip Dip LS/I electronic protection and a 36 kA breaking capacity, supporting dependable and configurable protection for demanding commercial and industrial electrical installations.