1SDX253994R1 ABB EPX-XT5N-E1-3203 320A 3-Pole 36kA Ekip Dip LS/I MCCB

1SDX253994R1 ABB EPX-XT5N-E1-3203 320A 3-Pole 36kA Ekip Dip LS/I MCCB

ABB EPX-XT5N-E1-3203 is a 320 A three-pole moulded case circuit breaker from the Protecta Power range, featuring a 36 kA breaking capacity at 415 V AC and Ekip Dip LS/I electronic overload and short-circuit protection for low-voltage electrical distribution systems.

SKU: 1SDX253994R1Alt SKU: EPX-XT5N-E1-3203MPN: 1SDX253994R1
Price
List Price £1,370.11 ex VAT
Your Price (ex VAT)
£1,370.11
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,370.11
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,370.11

Why Choose the ABB EPX-XT5N-E1-3203 320A 3-Pole MCCB?

The ABB EPX-XT5N-E1-3203 is a robust and reliable 320 A three-pole moulded case circuit breaker (MCCB) designed to provide advanced overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the proven ABB Tmax XT5N circuit breaker platform, it is engineered for commercial, industrial and infrastructure applications requiring dependable electrical protection and flexible circuit coordination.

This circuit breaker features an advanced ABB Ekip Dip LS/I electronic trip unit, providing long-time overload protection together with selectable short-time or instantaneous short-circuit protection. Its electronic protection technology enables configurable trip characteristics, helping electrical engineers coordinate protective devices and improve the reliability of power distribution installations.

With a rated current of 320 A and a 36 kA breaking capacity at 415 V AC, the EPX-XT5N-E1-3203 provides effective protection for three-phase electrical distribution circuits. Its XT5N400 frame, fixed-mounted construction and front terminal connections support straightforward integration into compatible ABB Protecta Power distribution equipment, electrical switchboards and industrial control panels.

Key Advantages

  • Reliable 320 A moulded case circuit breaker for low-voltage electrical distribution.
  • Three-pole configuration suitable for three-phase electrical systems.
  • 36 kA breaking capacity at 415 V AC provides effective short-circuit fault interruption.
  • Advanced ABB Ekip Dip LS/I electronic trip unit for configurable circuit protection.
  • Long-time overload protection (L) helps safeguard distribution cables and connected electrical equipment.
  • Selectable short-time (S) or instantaneous (I) protection supports different short-circuit protection requirements.
  • Electronic trip settings support coordination between upstream and downstream protective devices.
  • Robust ABB Tmax XT5N400 frame provides a compact solution for high-current distribution applications.
  • Designed for integration into ABB Protecta Power distribution systems.
  • Suitable for commercial, industrial and infrastructure electrical installations.

Key Features

  • ABB Protecta Power Devices range.
  • ABB Tmax XT5N moulded case circuit breaker platform.
  • 320 A rated electronic trip unit current.
  • Three-pole (3P) construction.
  • 36 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • Ekip Dip LS/I electronic protection unit.
  • Long-time (L) protection against sustained overload conditions.
  • Short-time (S) protection for short-circuit faults with intentional time delay.
  • Instantaneous (I) protection for rapid interruption of high-current faults.
  • Selectable short-time or instantaneous protection configuration.
  • XT5N400 frame with a maximum frame rating of 400 A.
  • 140 mm three-pole frame width for integration into distribution assemblies.
  • Electronic protection technology with configurable trip settings.
  • Fixed-mounted circuit breaker construction with front terminals.
  • Manual operating mechanism with trip indication and reset functionality.
  • Compatible with appropriately selected ABB Tmax XT5 installation accessories.

Reliable Electronic Circuit Protection for Industrial Electrical Distribution

Moulded case circuit breakers such as the ABB EPX-XT5N-E1-3203 protect electrical installations by automatically interrupting current when overload or short-circuit conditions occur. Its Ekip Dip LS/I electronic trip unit monitors electrical current and applies configurable protection characteristics to help safeguard distribution cables, electrical equipment and connected circuits. Long-time protection responds to sustained overloads, while selectable short-time or instantaneous protection provides the required response to short-circuit faults.

The ABB Tmax XT5 circuit breaker family is designed for dependable performance in modern low-voltage distribution systems. Its robust construction, electronic protection technology and compatibility with suitable ABB installation accessories support integration into commercial and industrial electrical infrastructure. The EPX-XT5N-E1-3203 is particularly suited to installations requiring 320 A three-pole circuit protection and a 36 kA fault-breaking rating at 415 V AC, subject to verification of the operating voltage, prospective fault current and protection coordination requirements.

Typical Applications

  • Commercial and industrial main electrical distribution boards.
  • ABB Protecta Power distribution assemblies.
  • Three-phase low-voltage electrical distribution systems.
  • Low-voltage main switchboards and sub-distribution panels.
  • Industrial machinery supply circuits and control panel incomers.
  • Building services and electrical infrastructure installations.
  • Electrical feeder and distribution circuit protection.
  • Manufacturing facilities, warehouses and commercial premises.
  • Industrial automation installations requiring electronic circuit protection.
  • Electrical installations requiring coordinated overload and short-circuit protection.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker series Tmax XT
Frame designation XT5N
ABB order code 1SDX253994R1
Corresponding ABB circuit breaker reference 1SDA100353R1
Product type Moulded case circuit breaker (MCCB)
Rated trip unit current 320 A
Number of poles 3
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 415 V AC
Trip unit type Ekip Dip LS/I
Trip unit technology Electronic
Long-time protection (L) Adjustable overload protection
Short-time protection (S) Short-circuit protection with intentional time delay
Instantaneous protection (I) Short-circuit protection without intentional time delay
Protection configuration Long-time protection with selectable short-time or instantaneous protection
Frame family XT5N400
Maximum frame rating 400 A
Rated operational voltage (series) Up to 690 V AC
Three-pole frame width 140 mm
Mounting type Fixed mounting
Terminal arrangement Front terminals
Operating mechanism Manual operation
Application Low-voltage three-phase electrical distribution
Installation Electrical distribution boards and compatible switchgear assemblies
Applicable circuit breaker standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT5N-E1-3203 used for?

The ABB EPX-XT5N-E1-3203 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations. Its electronic trip unit provides configurable protection for three-phase electrical systems.

What is the rated current of the EPX-XT5N-E1-3203?

The circuit breaker has a 320 A rated electronic trip unit current, making it suitable for appropriately designed electrical distribution circuits requiring protection up to 320 A. It uses the ABB XT5N400 frame, which has a maximum frame rating of 400 A.

What is the breaking capacity of this MCCB?

The EPX-XT5N-E1-3203 has a rated ultimate short-circuit breaking capacity of 36 kA at 415 V AC. The applicable breaking capacity must be checked against the installation voltage and prospective short-circuit current.

What protection does the Ekip Dip LS/I electronic trip unit provide?

The ABB Ekip Dip LS/I electronic trip unit provides long-time overload protection (L) together with selectable short-time short-circuit protection (S) or instantaneous short-circuit protection (I). These electronic protection functions allow the circuit breaker to be configured for the protection and coordination requirements of the electrical installation.

Where is the ABB EPX-XT5N-E1-3203 typically installed?

This MCCB is typically installed in low-voltage electrical distribution boards, industrial switchboards and compatible ABB Protecta Power assemblies, where three-pole electronic circuit protection is required. Its fixed-mounted construction and front terminal connections support integration into suitable electrical distribution panels.

Trusted by Electrical Engineers and Industrial Installers Worldwide

ABB Tmax XT moulded case circuit breakers are designed to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT5N-E1-3203 combines a 320 A electronic trip unit, three-pole construction and advanced Ekip Dip LS/I protection in a robust circuit breaker suitable for commercial, industrial and infrastructure power distribution applications.