ABB EPX-XT4N-E1-1603 is a 160 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and an adjustable Ekip LS/I electronic trip unit, providing configurable overload and selectable delayed or instantaneous short-circuit protection for commercial and industrial low-voltage electrical distribution systems.
£886.71
The ABB EPX-XT4N-E1-1603 is a high-performance 160 A three-pole moulded case circuit breaker (MCCB) designed to deliver reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Featuring a 36 kA short-circuit breaking capacity and an advanced Ekip LS/I electronic trip unit, this circuit breaker forms part of the ABB Protecta Power Devices range and incorporates ABB's established SACE Tmax XT4N circuit breaker technology.
Unlike conventional thermal-magnetic MCCBs, the EPX-XT4N-E1-1603 uses electronic protection technology to provide more flexible and precise adjustment of protective characteristics. Its LS/I trip unit combines long-time overload protection (L) with a selectable short-circuit protection function: either short-time delayed protection (S) or instantaneous protection (I). This allows the circuit breaker to be configured according to the requirements of the electrical installation and the desired protection coordination.
With a 160 A rated current, three-pole configuration and 36 kA breaking capacity, the ABB EPX-XT4N-E1-1603 is particularly suitable for three-phase outgoing circuits in commercial distribution boards, industrial electrical panels and compatible ABB Protecta Power assemblies. Supplied under ABB order code 1SDX253988R1, this electronic-trip MCCB provides a versatile circuit protection solution for demanding low-voltage distribution applications.
The ABB EPX-XT4N-E1-1603 combines the mechanical switching and fault-interruption capabilities of an ABB SACE Tmax XT4N MCCB with the configurable protection functions of an Ekip LS/I electronic trip unit. Electronic protection enables the circuit breaker to respond to overloads and short circuits according to selected current thresholds and time characteristics, supporting effective protection of cables, distribution equipment and connected electrical installations.
The long-time protection function (L) provides adjustable overload protection. For the 160 A electronic release, the long-time current threshold can be configured between 64 A and 160 A, corresponding to 0.4–1.0 × In. Its adjustable inverse-time characteristic allows the response to sustained overload conditions to be coordinated with the electrical circuit's operating characteristics and conductor protection requirements.
The LS/I designation identifies an important distinction from an LSI trip unit. The EPX-XT4N-E1-1603 provides long-time protection together with a choice between short-time delayed protection (S) and instantaneous protection (I). These short-circuit functions are alternative operating modes rather than three simultaneously active L, S and I functions. Short-time delayed protection can be useful where discrimination with downstream protective devices is required, while instantaneous protection provides rapid tripping when the selected fault-current threshold is reached.
The Ekip LS/I release allows the short-circuit threshold to be configured between 1 and 10 times the rated current, equivalent to 160–1,600 A for this 160 A device. In S mode, selectable short-time delays provide additional flexibility for coordinating protection with downstream circuit breakers. The appropriate settings must be established through the installation's electrical design and protection coordination assessment.
For commissioning and maintenance, the electronic trip unit includes front-accessible DIP switches, LED indications and a test connector for compatible ABB Ekip accessories. These features support practical adjustment, inspection and functional testing without relying solely on conventional thermal-magnetic mechanisms.
As part of the ABB Protecta Power Devices range, the EPX-XT4N-E1-1603 is intended for installation in compatible electrical distribution assemblies. Its 36 kA short-circuit breaking capacity must be assessed against the prospective fault current and operating voltage of the installation. Correct protective settings, conductor sizing and accessory selection are essential for dependable performance.
| Product group | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT4 / Protecta Power |
| ABB order code | 1SDX253988R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current (In) | 160 A |
| Number of poles | 3 |
| Pole configuration | 3P |
| Short-circuit breaking capacity | 36 kA |
| Breaking capacity classification | N (normal breaking capacity) |
| Trip unit type | Ekip LS/I electronic |
| Protection technology | Electronic overcurrent release |
| Long-time protection (L) | Adjustable overload protection |
| Long-time current threshold (I1) | 0.4–1.0 × In |
| Long-time current threshold range at 160 A In | 64–160 A |
| Long-time trip characteristic | Adjustable inverse-time characteristic |
| Short-time protection (S) | Selectable delayed short-circuit protection |
| Instantaneous protection (I) | Selectable instantaneous short-circuit protection |
| S/I protection configuration | Select either S or I short-circuit protection |
| Short-circuit threshold adjustment | 1–10 × In |
| Short-circuit threshold range at 160 A In | 160–1,600 A |
| Short-time delay settings (S) | 0.1 or 0.2 s |
| Protection adjustment method | Front-mounted DIP switches |
| Trip-unit indications | LED status and protection indications |
| Test interface | Front connector for compatible Ekip testing accessories |
| Electronic trip-unit supply | Self-powered under specified current conditions |
| Frame family | XT4N |
| Rated operational voltage (XT4N family) | Up to 690 V AC |
| Rated insulation voltage (XT4N family) | 1,000 V |
| Rated impulse withstand voltage (XT4N family) | 8 kV |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
| Application | Low-voltage electrical distribution |
| Installation type | Compatible electrical distribution board / switchgear assembly |
| Operating mechanism | Manual toggle-operated circuit breaker |
| Typical electrical system | Three-phase AC distribution |
The ABB EPX-XT4N-E1-1603 is a 160 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an Ekip LS/I electronic trip unit and is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.
The EPX-XT4N-E1-1603 has a 160 A rated current. Its electronic long-time overload protection can be adjusted below the rated current to suit appropriately designed and protected electrical circuits.
The ABB EPX-XT4N-E1-1603 has a specified 36 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the installation voltage and prospective fault current before selecting the device.
Ekip LS/I is an electronic trip unit providing long-time overload protection (L) together with a selectable short-circuit protection function. The user can configure either short-time delayed protection (S) or instantaneous protection (I), depending on the protection requirements of the installation.
An Ekip LS/I trip unit provides long-time protection with a choice between short-time delayed or instantaneous short-circuit protection. An Ekip LSI trip unit provides separate L, S and I protection functions for configuration. The two trip-unit types should not be treated as interchangeable without reviewing the required protection characteristics.
Yes. The Ekip LS/I electronic trip unit provides an adjustable long-time overload threshold from 0.4 to 1.0 times the rated current. For this 160 A MCCB, that corresponds to a setting range of 64–160 A, subject to the manufacturer's available adjustment steps.
Yes. The Ekip LS/I trip unit allows the selection of either short-time delayed protection (S) or instantaneous protection (I). The short-circuit threshold is adjustable from 1–10 × In, corresponding to 160–1,600 A for this 160 A device. S mode also provides selectable short-time delay settings.
The protection settings are configured using DIP switches on the front of the electronic trip unit. These allow the appropriate overload threshold, trip characteristic and selected short-circuit protection mode to be set according to ABB's instructions and the installation's protection coordination requirements.
The standard Ekip LS/I electronic trip unit provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where earth-leakage protection is required, an appropriate additional protective device or compatible solution must be specified.
The ABB manufacturer order code is 1SDX253988R1. The corresponding product reference is EPX-XT4N-E1-1603, identifying the 160 A, three-pole, 36 kA electronic-trip MCCB with Ekip LS/I protection within the ABB Protecta Power Devices range.
ABB Protecta Power circuit protection devices combine established SACE Tmax XT circuit breaker technology with configurable electronic protection. The EPX-XT4N-E1-1603 delivers 160 A three-pole protection, a 36 kA short-circuit breaking capacity and versatile Ekip LS/I functionality for appropriately specified commercial and industrial low-voltage electrical distribution systems.