1SDX253986R1 ABB EPX-XT4N-E1-1003 100A 3P 36kA LS/I Electronic Moulded Case Circuit Breaker

1SDX253986R1 ABB EPX-XT4N-E1-1003 100A 3P 36kA LS/I Electronic Moulded Case Circuit Breaker

ABB EPX-XT4N-E1-1003 (1SDX253986R1) is a 100 A three-pole SACE Tmax XT4N160 moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and ABB Ekip LS/I electronic protection. Designed for compatible ABB Protecta Power distribution assemblies, it provides configurable overload and short-circuit protection for three-phase outgoing circuits.

SKU: 1SDX253986R1Alt SKU: EPX-XT4N-E1-1003MPN: 1SDX253986R1
Price
List Price £810.34 ex VAT
Your Price (ex VAT)
£810.34
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £810.34
Trade pricing is personalised to your account

Manufacturer Lead Time

£810.34

Why Choose the ABB EPX-XT4N-E1-1003 100A 3-Pole Electronic Moulded Case Circuit Breaker?

The ABB EPX-XT4N-E1-1003 is a high-performance 100 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT4N160 circuit breaker platform, this protective device combines robust construction with advanced electronic trip technology for commercial, industrial and building services applications.

As part of the ABB Protecta Power Devices product group, the EPX-XT4N-E1-1003 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its ABB Ekip LS/I electronic trip configuration provides long-time overload protection and selectable short-circuit protection characteristics, enabling electrical engineers to coordinate the protective device with the requirements of the electrical installation.

With a 100 A rated current, a specified 36 kA short-circuit breaking capacity and a three-pole (3P) configuration, the EPX-XT4N-E1-1003 is suitable for appropriately designed three-phase outgoing feeders, commercial distribution boards, industrial electrical panels and building services installations. Its 110 mm nominal device width supports efficient use of space within compatible electrical distribution assemblies.

Identified by ABB order code 1SDX253986R1, this electronic MCCB offers a clearly specified solution for electrical contractors, consulting engineers, panel builders and facilities managers seeking dependable 100 A circuit protection with configurable electronic trip characteristics.

Key Advantages

  • 100 A rated current for dependable protection of appropriately designed three-phase electrical distribution circuits.
  • 36 kA short-circuit breaking capacity in the specified ABB Protecta Power application.
  • Three-pole (3P) construction provides coordinated switching and protection of three phase conductors.
  • Electronic LS/I trip protection offers configurable overload and short-circuit protection characteristics.
  • ABB Ekip electronic trip technology supports consistent protective operation and setting flexibility.
  • Long-time overload protection (L) helps safeguard cables and connected equipment against sustained excessive current.
  • Selectable short-time (S) or instantaneous (I) protection supports different short-circuit protection strategies.
  • Electronic trip adjustment helps engineers coordinate protective devices across the electrical distribution system.
  • Based on the established ABB SACE Tmax XT4N160 platform.
  • 160 A frame platform provides a robust foundation for the 100 A protective device.
  • 110 mm nominal width supports compact distribution board layouts.
  • Designed for integration into compatible ABB Protecta Power distribution assemblies.
  • Suitable for new installations, electrical distribution upgrades and industrial panel-building projects.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT4N-E1-1003 product designation.
  • ABB order code 1SDX253986R1.
  • ABB SACE Tmax XT4N160 circuit breaker platform.
  • 100 A rated current for outgoing circuit protection.
  • 160 A frame rating within the XT4N160 platform.
  • 36 kA specified short-circuit breaking capacity.
  • Three-pole (3P) configuration for three-phase electrical distribution.
  • ABB Ekip LS/I electronic trip unit for configurable protection.
  • Long-time protection (L) against sustained overload conditions.
  • Short-time protection (S) for delayed short-circuit operation when selected.
  • Instantaneous protection (I) for rapid short-circuit operation when selected.
  • LS/I protection arrangement provides long-time protection with a choice of short-time or instantaneous short-circuit characteristics.
  • Electronic protection settings support coordination with appropriately rated cables and connected equipment.
  • 110 mm nominal device width for efficient distribution board installation.
  • Manual operating mechanism for circuit switching and isolation when correctly installed.
  • Suitable for installation using compatible ABB Protecta Power mounting and connection accessories.

Advanced 100A Electronic LS/I Circuit Protection for Three-Phase Electrical Distribution

The ABB EPX-XT4N-E1-1003 100 A electronic MCCB is designed to help maintain the safety and reliability of low-voltage electrical distribution networks. Moulded case circuit breakers protect electrical circuits by automatically interrupting current when abnormal operating conditions occur. The electronic trip system provides configurable protection characteristics, making it suitable for installations where engineers require greater flexibility than conventional thermal-magnetic protection can offer.

The ABB Ekip LS/I electronic trip unit provides long-time overload protection (L), helping prevent excessive heating of conductors and electrical equipment during sustained overcurrent conditions. It also provides a choice between short-time delayed protection (S) and instantaneous protection (I) for short-circuit conditions. This flexibility supports the development of appropriate protection strategies for different electrical distribution applications.

The distinction between LS/I and LSI is particularly important when specifying electronic circuit breakers. An LS/I release provides long-time overload protection with a choice between short-time and instantaneous short-circuit protection modes. An LSI release incorporates long-time, short-time and instantaneous protection characteristics together. Selecting the correct trip arrangement helps engineers achieve the required balance between fault protection and coordination with other protective devices.

The three-pole construction provides coordinated protection and switching of all three phase conductors. This makes the EPX-XT4N-E1-1003 suitable for three-phase outgoing feeders, commercial distribution circuits and industrial electrical installations where a dedicated switched neutral pole is not required. The circuit breaker can form part of a wider protection system incorporating upstream and downstream protective devices selected for the electrical installation.

Built around the ABB SACE Tmax XT4N160 platform, the EPX-XT4N-E1-1003 combines a 100 A rated current with a specified 36 kA short-circuit breaking capacity. Its 110 mm nominal width helps support efficient distribution board design while providing the benefits of electronic trip technology.

Correct selection and installation should consider the system operating voltage, prospective short-circuit current, cable sizing, electronic trip settings, discrimination requirements and compatibility with the electrical distribution assembly. The applicable breaking capacity and exact Ekip LS/I adjustment ranges should be verified against the relevant ABB technical documentation before installation and commissioning.

Typical Applications

  • ABB Protecta Power distribution boards requiring 100 A three-pole electronic MCCB protection.
  • Commercial building electrical distribution and outgoing feeder circuits.
  • Industrial electrical panels supplying appropriately rated three-phase loads.
  • Three-phase sub-distribution systems requiring configurable electronic protection.
  • Building services installations supplying mechanical and electrical plant.
  • Manufacturing facilities and workshop electrical distribution networks.
  • Warehouses and logistics centres with three-phase electrical infrastructure.
  • Office buildings and retail premises with dedicated outgoing electrical feeders.
  • Distribution board refurbishment projects using compatible ABB Protecta Power equipment.
  • Switchboard manufacturing and panel-building projects requiring a 100 A, 3P, 36 kA electronic LS/I MCCB.

Technical Specifications

Product group Protecta Power Devices
Product range SACE Tmax XT
Circuit breaker platform XT4N160
Model / SKU EPX-XT4N-E1-1003
ABB order code 1SDX253986R1
Product type Moulded case circuit breaker (MCCB)
Rated current 100 A
Frame rating 160 A
Short-circuit breaking capacity 36 kA (specified Protecta Power application)
Number of poles 3
Pole configuration Three-pole (3P)
Trip unit ABB Ekip LS/I electronic release
Trip technology Electronic
Protection designation LS/I
Long-time protection (L) Overload protection
Short-time protection (S) Selectable delayed short-circuit protection
Instantaneous protection (I) Selectable instantaneous short-circuit protection
Protection arrangement Long-time protection with a choice of short-time or instantaneous short-circuit characteristics
Electronic trip adjustment Refer to the fitted ABB Ekip LS/I release documentation
Neutral switching No dedicated switched neutral pole
Applicable circuit breaker standard IEC 60947-2
Nominal device width 110 mm
Installation type Fixed installation within a compatible distribution assembly
Mounting compatibility ABB Protecta Power, subject to appropriate mounting and connection arrangements
Electrical application Three-phase low-voltage power distribution
Typical use Outgoing feeder and sub-distribution circuit protection

Frequently Asked Questions

What is the ABB EPX-XT4N-E1-1003 used for?

The ABB EPX-XT4N-E1-1003 is a 100 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It uses an ABB Ekip LS/I electronic trip unit and is intended for compatible ABB Protecta Power distribution assemblies.

What are the rated current and breaking capacity of the EPX-XT4N-E1-1003?

The EPX-XT4N-E1-1003 has a 100 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It uses the ABB SACE Tmax XT4N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be checked against the installation operating voltage and prospective fault current.

What does LS/I mean on the ABB EPX-XT4N-E1-1003?

LS/I identifies an electronic protection arrangement providing long-time overload protection (L) together with a choice of short-time delayed short-circuit protection (S) or instantaneous short-circuit protection (I). The selected protection mode and adjustment settings should be determined according to the electrical installation design and the manufacturer's instructions.

What is the advantage of the three-pole configuration?

The three-pole (3P) configuration enables coordinated switching and protection of three phase conductors, making the EPX-XT4N-E1-1003 suitable for appropriately designed three-phase electrical distribution circuits. Unlike a four-pole MCCB, it does not include a dedicated switched neutral pole.

Where can the ABB EPX-XT4N-E1-1003 be installed?

The breaker is intended for installation within compatible ABB Protecta Power distribution boards, using the appropriate mounting and connection arrangements. The ABB XT4 three-pole platform has a nominal width of 110 mm. Installation and electronic trip configuration should be carried out by a competent electrical professional in accordance with the circuit design and applicable electrical regulations.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are established components in low-voltage electrical distribution, providing dependable protection for commercial and industrial installations. The ABB EPX-XT4N-E1-1003 combines a 100 A rated current, three-pole switching, specified 36 kA short-circuit breaking capacity and configurable ABB Ekip LS/I electronic protection in a robust device intended for compatible ABB Protecta Power distribution systems.