1SDX253984R1 ABB EPX-XT4N-E1-0403 40A 3-Pole 36kA LS/I Electronic MCCB

1SDX253984R1 ABB EPX-XT4N-E1-0403 40A 3-Pole 36kA LS/I Electronic MCCB

ABB EPX-XT4N-E1-0403 is a 40 A three-pole 36 kA electronic moulded case circuit breaker from the Protecta Power Devices range, featuring LS/I protection for adjustable overload and short-circuit protection in low-voltage electrical distribution systems.

SKU: 1SDX253984R1Alt SKU: EPX-XT4N-E1-0403MPN: 1SDX253984R1
Price
List Price £795.61 ex VAT
Your Price (ex VAT)
£795.61
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £795.61
Trade pricing is personalised to your account

Manufacturer Lead Time

£795.61

Why Choose the ABB EPX-XT4N-E1-0403 40A 3-Pole MCCB?

The ABB EPX-XT4N-E1-0403 is a reliable 40 A three-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the established ABB SACE Tmax XT4N circuit breaker platform, it combines electronic protection technology with robust construction for commercial, industrial and building infrastructure applications.

This circuit breaker features LS/I electronic trip protection, providing long-time overload protection together with selectable short-time or instantaneous short-circuit protection. Its electronic protection system offers greater flexibility than conventional thermal-magnetic protection, allowing suitable trip characteristics to be selected for electrical distribution networks where protective device coordination is important.

With a rated current of 40 A, a three-pole configuration and a specified 36 kA short-circuit breaking capacity, the EPX-XT4N-E1-0403 provides dependable protection for three-phase outgoing feeders and distribution circuits. Its ABB Tmax XT4 frame supports installation within compatible Protecta Power distribution boards and electrical switchgear assemblies.

Key Advantages

  • Reliable 40 A moulded case circuit breaker for low-voltage electrical distribution.
  • Three-pole configuration suitable for three-phase electrical circuits.
  • 36 kA specified breaking capacity for protection against high prospective short-circuit currents under the applicable rated conditions.
  • LS/I electronic trip protection provides flexible overload and short-circuit protection.
  • Long-time overload protection (L) helps prevent damage caused by sustained excessive current.
  • Selectable short-time (S) or instantaneous (I) protection supports different short-circuit protection requirements.
  • Electronic protection settings facilitate coordination with other protective devices.
  • Established ABB SACE Tmax XT4N platform for dependable circuit protection.
  • Designed for integration into ABB Protecta Power distribution systems.
  • Robust moulded case construction supports reliable operation in commercial and industrial installations.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB SACE Tmax XT4N moulded case circuit breaker platform.
  • 40 A rated current.
  • Three-pole (3P) configuration.
  • 36 kA specified short-circuit breaking capacity.
  • Electronic LS/I trip unit for overload and short-circuit protection.
  • L protection: Long-time overload protection.
  • S protection: Short-time delayed short-circuit protection, selectable as an alternative to instantaneous protection.
  • I protection: Instantaneous short-circuit protection, selectable as an alternative to short-time protection.
  • ABB Tmax XT4 frame family for low-voltage electrical distribution.
  • 105 mm nominal width for the three-pole XT4 frame.
  • Electronic trip technology supports adjustable protection characteristics.
  • Manual front-operated switching mechanism with circuit breaker trip indication.
  • Suitable for installation with appropriately selected ABB Tmax XT4 mounting and connection accessories.
  • Designed for circuit protection, switching and isolation within compatible electrical distribution assemblies.

Reliable Electronic Circuit Protection for Low-Voltage Distribution

Electronic moulded case circuit breakers such as the ABB EPX-XT4N-E1-0403 protect electrical installations by monitoring circuit current and initiating automatic disconnection when overload or short-circuit conditions exceed the configured protection thresholds. The LS/I electronic trip unit provides long-time overload protection together with a choice between short-time delayed and instantaneous short-circuit protection. This flexibility helps electrical engineers coordinate protective devices and select suitable protection characteristics for individual circuits.

The ABB SACE Tmax XT4N platform combines robust construction with electronic protection technology for modern low-voltage distribution systems. Its three-pole configuration supports protection of three-phase circuits, while compatibility with appropriately selected XT4 installation accessories facilitates integration into ABB Protecta Power distribution assemblies. Correct selection of trip settings, cable ratings, prospective fault current and upstream and downstream protective devices remains essential for safe and effective operation.

Typical Applications

  • ABB Protecta Power distribution boards and panelboard assemblies.
  • Commercial building low-voltage electrical distribution.
  • Industrial electrical distribution panels and switchboards.
  • Three-phase outgoing feeder protection.
  • Main and sub-distribution boards requiring electronic circuit protection.
  • Electrical control panels and industrial machinery supply circuits.
  • Building services, mechanical plant and infrastructure electrical systems.
  • Commercial premises, offices, warehouses and retail distribution installations.
  • Electrical networks requiring adjustable overload and short-circuit protection.
  • Distribution board installations designed around the ABB Tmax XT4 circuit breaker platform.

Technical Specifications

Product range Protecta Power Devices
Series SACE Tmax XT4
ABB order code 1SDX253984R1
Product type Moulded case circuit breaker (MCCB)
Frame designation XT4N
Frame current class 250 A
Rated current (In) 40 A
Number of poles 3
Specified short-circuit breaking capacity 36 kA
Trip unit technology Electronic
Trip unit protection LS/I
Long-time protection (L) Overload protection
Short-time protection (S) Short-circuit protection with time delay
Instantaneous protection (I) Short-circuit protection without intentional time delay
Protection configuration Long-time protection with selectable S or I function
Rated insulation voltage (Ui), XT4 series 1000 V
Rated impulse withstand voltage (Uimp), XT4 series 8 kV
Electrical system Low-voltage three-phase AC distribution
Nominal device width 105 mm
Operating mechanism Manual toggle operation
Application Circuit protection, switching and isolation
Product family standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4N-E1-0403 used for?

The ABB EPX-XT4N-E1-0403 is a three-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial distribution boards, including compatible ABB Protecta Power assemblies.

What is the rated current of the EPX-XT4N-E1-0403?

The circuit breaker has a 40 A rated current and uses the ABB SACE Tmax XT4N platform. The wider XT4 frame family has a current class of up to 250 A, but this particular device is rated at 40 A.

What is the breaking capacity of this ABB MCCB?

The EPX-XT4N-E1-0403 has a specified 36 kA short-circuit breaking capacity. The applicable operating voltage, prospective short-circuit current and manufacturer rating conditions should be checked when selecting the breaker for an installation.

What does LS/I electronic protection mean?

LS/I identifies an electronic trip unit providing long-time overload protection (L) together with selectable short-time delayed (S) or instantaneous (I) short-circuit protection. The S and I functions are alternative protection modes, allowing the circuit breaker to be configured for the required protection characteristics.

What is the difference between an LS/I electronic MCCB and a thermal-magnetic MCCB?

An LS/I electronic MCCB uses electronic current monitoring and adjustable protection characteristics, while a conventional thermal-magnetic MCCB uses thermal and magnetic elements to respond to overloads and short circuits. Electronic protection offers additional flexibility when coordinating protective devices within electrical distribution systems.

Can the EPX-XT4N-E1-0403 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT4N-E1-0403 belongs to the ABB Protecta Power Devices range and is intended for integration into compatible low-voltage distribution assemblies. The appropriate XT4 mounting arrangement, electrical connections and enclosure compatibility should be verified before installation.

Trusted by Electrical Engineers and Distribution Panel Builders

ABB SACE Tmax XT electronic moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining flexible electronic trip functionality, robust construction and dependable circuit protection for modern low-voltage power systems.