1SDX253982R1 ABB EPX-XT2N-E1-1603 160A 3-Pole 36kA Ekip LS/I Electronic MCCB

1SDX253982R1 ABB EPX-XT2N-E1-1603 160A 3-Pole 36kA Ekip LS/I Electronic MCCB

ABB EPX-XT2N-E1-1603 is a 160 A three-pole 36 kA electronic moulded case circuit breaker from the Protecta Power Devices range, featuring Ekip LS/I protection for adjustable overload and short-circuit protection in low-voltage electrical distribution systems.

SKU: 1SDX253982R1Alt SKU: EPX-XT2N-E1-1603MPN: 1SDX253982R1
Price
List Price £842.09 ex VAT
Your Price (ex VAT)
£842.09
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £842.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£842.09

Why Choose the ABB EPX-XT2N-E1-1603 160A 3-Pole MCCB?

The ABB EPX-XT2N-E1-1603 is a high-performance 160 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the established ABB SACE Tmax XT2N circuit breaker platform, it combines advanced electronic protection technology with compact construction for commercial, industrial and building infrastructure applications.

This circuit breaker features an ABB Ekip LS/I electronic trip unit, providing long-time overload protection and selectable short-time or instantaneous short-circuit protection. Unlike conventional thermal-magnetic circuit breakers, its electronic protection system offers flexible protection settings to support circuit coordination and the requirements of modern electrical distribution networks.

With a rated current of 160 A, a three-pole configuration and a 36 kA short-circuit breaking capacity at 415 V AC, the EPX-XT2N-E1-1603 is suitable for protecting three-phase outgoing feeders and distribution circuits. Its compact 100 mm-wide XT2 frame enables space-efficient installation within compatible ABB Protecta Power distribution boards and low-voltage switchgear assemblies.

Key Advantages

  • Reliable 160 A moulded case circuit breaker for commercial and industrial power distribution.
  • Three-pole configuration designed for three-phase electrical circuits.
  • 36 kA breaking capacity at 415 V AC for protection against high prospective short-circuit currents.
  • Advanced ABB Ekip LS/I electronic trip unit for flexible circuit protection.
  • Long-time overload protection (L) helps prevent damage caused by sustained excessive current.
  • Selectable short-time (S) or instantaneous (I) protection supports different short-circuit protection requirements.
  • Electronic protection settings facilitate coordination with other protective devices.
  • Compact ABB Tmax XT2N frame with a nominal width of 100 mm.
  • Designed for integration into ABB Protecta Power distribution systems.
  • Robust moulded case construction and established ABB protection technology support dependable operation.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB SACE Tmax XT2N moulded case circuit breaker platform.
  • 160 A rated current.
  • Three-pole (3P) configuration.
  • 36 kA rated short-circuit breaking capacity at 415 V AC.
  • Ekip LS/I electronic trip unit for adjustable protection.
  • L protection: Long-time overload protection.
  • S protection: Short-time delayed short-circuit protection, selectable as an alternative to I protection.
  • I protection: Instantaneous short-circuit protection, selectable as an alternative to S protection.
  • XT2N 160 A frame for low-voltage distribution applications.
  • 100 mm nominal device width for compact three-pole installation.
  • Electronic trip technology designed for accurate and repeatable protection operation.
  • Fixed circuit breaker construction with front-terminal connection arrangement on the corresponding XT2N configuration.
  • Manual switching mechanism with circuit breaker trip indication.
  • Compatible with appropriately selected ABB Tmax XT2 mounting, connection and operating accessories.

Reliable Electronic Circuit Protection for Industrial Power Distribution

Electronic moulded case circuit breakers such as the ABB EPX-XT2N-E1-1603 protect electrical installations by monitoring current and initiating automatic disconnection when overload or short-circuit conditions exceed the configured protection thresholds. The Ekip LS/I electronic trip unit provides long-time overload protection together with a choice between short-time delayed and instantaneous short-circuit protection. This enables protection characteristics to be selected according to the electrical installation and its coordination requirements.

The ABB SACE Tmax XT2N platform combines compact construction with electronic protection technology designed for modern low-voltage distribution systems. Its three-pole arrangement is suitable for protecting three-phase circuits, while its compact 100 mm width supports efficient integration into compatible ABB Protecta Power distribution boards. Correct selection of protection settings, verification of prospective short-circuit current and coordination with upstream and downstream devices remain essential for safe and reliable operation.

Typical Applications

  • ABB Protecta Power distribution boards and panelboard assemblies.
  • Commercial building low-voltage electrical distribution.
  • Industrial electrical distribution panels and switchboards.
  • Three-phase outgoing feeder protection.
  • Main and sub-distribution boards requiring electronic circuit protection.
  • Electrical control panels and industrial machinery supply circuits.
  • Building services, mechanical plant and infrastructure electrical systems.
  • Commercial premises, warehouses, offices and retail distribution installations.
  • Electrical networks requiring adjustable overload and short-circuit protection.
  • Low-voltage distribution systems requiring compact 160 A electronic MCCBs.

Technical Specifications

Product range Protecta Power Devices
Series SACE Tmax XT2
ABB order code 1SDX253982R1
Product type Moulded case circuit breaker (MCCB)
Frame designation XT2N
Frame size 160 A
Rated current (In) 160 A
Number of poles 3
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 415 V AC
Rated service short-circuit breaking capacity (Ics), corresponding XT2N configuration 36 kA at 415 V AC
Trip unit technology Electronic
Trip unit series ABB Ekip LS/I
Protection functions Long-time overload (L) and selectable short-time (S) or instantaneous (I) short-circuit protection
Rated operational voltage (Ue), XT2N series Up to 690 V AC
Rated insulation voltage (Ui), XT2N series 1000 V
Rated impulse withstand voltage (Uimp), XT2N series 8 kV
Electrical system Low-voltage three-phase AC distribution
Mounting arrangement Fixed installation
Terminal arrangement Front terminals on the corresponding XT2N configuration
Nominal device width 100 mm
Operating mechanism Manual toggle operation
Application Circuit protection, switching and isolation
Product family standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT2N-E1-1603 used for?

The ABB EPX-XT2N-E1-1603 is a three-pole electronic moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial distribution boards, including compatible ABB Protecta Power assemblies.

What is the rated current of the EPX-XT2N-E1-1603?

The circuit breaker has a 160 A rated current and uses the ABB SACE Tmax XT2N 160 A frame. It is intended for appropriately designed three-phase circuits requiring electronic protection at this current rating.

What is the breaking capacity of this ABB MCCB?

The EPX-XT2N-E1-1603 has a 36 kA short-circuit breaking capacity at 415 V AC. The corresponding ABB XT2N electronic breaker configuration also has a rated service short-circuit breaking capacity of 36 kA at this voltage. The installation's prospective fault current must be considered when selecting the breaker.

What does LS/I electronic protection mean?

LS/I identifies an electronic trip unit providing long-time overload protection (L) together with selectable short-time delayed (S) or instantaneous (I) short-circuit protection. The S and I functions are alternative protection modes, allowing the circuit breaker to be configured for the required protection characteristics.

What is the difference between an Ekip LS/I breaker and a thermal-magnetic MCCB?

An Ekip LS/I electronic MCCB uses an electronic trip unit with adjustable protection characteristics, while a conventional thermal-magnetic MCCB uses thermal and magnetic elements to respond to overloads and short circuits. Electronic protection provides additional flexibility when coordinating protective devices in electrical distribution systems.

Can the EPX-XT2N-E1-1603 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT2N-E1-1603 belongs to the ABB Protecta Power Devices range and is designed for integration into compatible low-voltage distribution assemblies. The appropriate XT2 mounting arrangement, electrical connections and enclosure compatibility should be verified before installation.

Trusted by Electrical Engineers and Distribution Panel Builders

ABB SACE Tmax XT electronic moulded case circuit breakers provide established protection technology for commercial and industrial electrical distribution, combining flexible electronic trip functionality, compact construction and dependable circuit protection for modern low-voltage power systems.