ABB EPX-XT2N-E1-1003 is a 100 A three-pole SACE Tmax XT2N160 moulded case circuit breaker with 36 kA breaking capacity at 415 V AC and Ekip LS/I electronic overload and short-circuit protection for commercial and industrial low-voltage electrical distribution systems.
£648.09
The ABB EPX-XT2N-E1-1003 is a high-performance 100 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the ABB SACE Tmax XT2N160 platform with an Ekip LS/I electronic trip unit, delivering configurable protection for three-phase electrical installations.
Featuring a 36 kA short-circuit breaking capacity at 415 V AC, the EPX-XT2N-E1-1003 is designed to interrupt electrical faults while helping protect cables, switchgear and connected equipment. Its electronic trip unit provides long-time overload protection (L) together with selectable short-time delayed (S) or instantaneous (I) short-circuit protection, supporting effective protective device coordination.
With a 100 A rated current, three-pole configuration and compact 100 mm nominal width, this MCCB is suitable for outgoing feeders, commercial distribution boards and industrial switchboards. Its established ABB Tmax XT2N construction and compatibility with appropriately configured ABB Protecta Power distribution assemblies make it a practical choice for electrical contractors, panel builders and maintenance engineers.
The ABB EPX-XT2N-E1-1003 incorporates an Ekip LS/I electronic trip unit designed to protect electrical installations against overloads and short-circuit faults. Electronic protection technology uses current sensing and electronic processing to deliver defined protective characteristics, helping engineers coordinate protective devices throughout low-voltage distribution systems.
The L (long-time) protection function responds to sustained excessive current, helping prevent overheating of electrical conductors and connected equipment. The S/I protection arrangement provides a choice between short-time delayed short-circuit protection and instantaneous short-circuit protection. Short-time delay can support selectivity with downstream devices, while instantaneous protection enables rapid interruption of high fault currents.
The ABB SACE Tmax XT2N160 platform combines electronic protection with robust moulded case construction. Its three-pole configuration enables simultaneous switching of three phase conductors, making it suitable for appropriately designed commercial and industrial three-phase electrical distribution circuits.
When installing the EPX-XT2N-E1-1003 within an ABB Protecta Power distribution board, appropriate mounting components, terminal connections and protective covers must be selected. Electrical designers should verify the prospective short-circuit current, conductor ratings, electronic trip settings and protective device coordination before commissioning.
| Product range | Protecta Power Devices |
|---|---|
| Circuit breaker series | SACE Tmax XT |
| Circuit breaker frame | XT2 |
| Performance level | XT2N |
| Frame configuration | XT2N160 |
| ABB order code | 1SDX253980R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 100 A |
| Maximum frame rating | 160 A |
| Number of poles | 3P (three pole) |
| Rated ultimate short-circuit breaking capacity (Icu) | 36 kA at 415 V AC |
| Rated service short-circuit breaking capacity (Ics) | 36 kA at 415 V AC |
| Trip unit | Ekip LS/I |
| Trip technology | Electronic |
| Overload protection | L – long-time protection |
| Short-circuit protection | S/I – selectable short-time delayed or instantaneous protection |
| Rated operational voltage | Up to 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Rated frequency | 50/60 Hz |
| Nominal width | 100 mm |
| Applicable standard | IEC 60947-2 |
| Installation type | Electrical distribution board / switchboard mounting |
| Compatible system | ABB Protecta Power |
| Product category | Protecta Power Devices |
The ABB EPX-XT2N-E1-1003 is a 100 A three-pole moulded case circuit breaker designed to protect commercial and industrial low-voltage electrical distribution circuits against overloads and short circuits using an Ekip LS/I electronic trip unit.
The EPX-XT2N-E1-1003 has a 100 A rated current and uses the ABB SACE Tmax XT2N160 platform, which has a maximum frame rating of 160 A. The frame rating does not change the specified 100 A rating of this device.
The EPX-XT2N-E1-1003 has a 36 kA rated ultimate short-circuit breaking capacity at 415 V AC. Its rated service breaking capacity at the same voltage is also 36 kA. The applicable breaking capacity must be checked against the operating voltage and prospective fault current of the installation.
LS/I identifies an electronic protection arrangement providing L (long-time overload protection) with a choice between S (short-time delayed short-circuit protection) and I (instantaneous short-circuit protection). The S and I functions are selectable alternatives rather than simultaneous independent functions.
Ekip LS/I provides long-time overload protection with a choice between short-time delayed and instantaneous short-circuit protection. Ekip LSI provides long-time, short-time delayed and instantaneous protection functions together, offering additional flexibility for protection coordination.
Both circuit breakers use the ABB SACE Tmax XT2N160 three-pole platform and feature 36 kA breaking capacity with Ekip LS/I electronic protection. The EPX-XT2N-E1-0633 has a rated current of 63 A, while the EPX-XT2N-E1-1003 has a rated current of 100 A.
Yes. Its three-pole configuration enables simultaneous switching and protection of three phase conductors, making it suitable for compatible three-phase low-voltage distribution circuits requiring a 100 A protective device.
Yes. The EPX-XT2N-E1-1003 belongs to the ABB Protecta Power Devices range and is intended for compatible electrical distribution assemblies. Appropriate XT2 mounting components, terminal connections, covers and installation accessories must be selected according to the switchboard configuration.
ABB SACE Tmax XT moulded case circuit breakers provide dependable overload and short-circuit protection for commercial and industrial electrical installations. The EPX-XT2N-E1-1003 combines a 100 A three-pole XT2N160 circuit breaker with 36 kA breaking capacity and Ekip LS/I electronic protection, delivering a compact and configurable solution for compatible ABB Protecta Power distribution assemblies.