1SDX253976R1 ABB EPX-XT2N-E1-0253 25A 3-Pole 36kA Ekip Dip LS/I MCCB

1SDX253976R1 ABB EPX-XT2N-E1-0253 25A 3-Pole 36kA Ekip Dip LS/I MCCB

ABB EPX-XT2N-E1-0253 is a 25 A three-pole moulded case circuit breaker from the Protecta Power range, featuring a 36 kA breaking capacity at 415 V AC and Ekip Dip LS/I electronic overload and short-circuit protection for low-voltage electrical distribution systems.

SKU: 1SDX253976R1Alt SKU: EPX-XT2N-E1-0253MPN: 1SDX253976R1
Price
List Price £648.09 ex VAT
Your Price (ex VAT)
£648.09
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £648.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£648.09

Why Choose the ABB EPX-XT2N-E1-0253 25A 3-Pole MCCB?

The ABB EPX-XT2N-E1-0253 is a compact and reliable 25 A three-pole moulded case circuit breaker (MCCB) designed to provide advanced overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the proven ABB Tmax XT2N circuit breaker platform, it is engineered for commercial, industrial and infrastructure applications requiring dependable electrical protection and flexible circuit coordination.

This circuit breaker features an advanced ABB Ekip Dip LS/I electronic trip unit, providing long-time overload protection together with selectable short-time or instantaneous short-circuit protection functions. Unlike conventional thermal-magnetic circuit breakers, its electronic protection technology enables more flexible adjustment of trip characteristics, helping electrical engineers coordinate protection settings with the requirements of the installation.

With a rated current of 25 A and a 36 kA breaking capacity at 415 V AC, the EPX-XT2N-E1-0253 provides reliable protection for three-phase electrical distribution circuits. Its compact XT2N160 frame, fixed-mounted construction and front terminal connections support straightforward integration into compatible ABB Protecta Power distribution equipment, electrical switchboards and industrial control panels.

Key Advantages

  • Reliable 25 A moulded case circuit breaker for low-voltage electrical distribution.
  • Three-pole configuration suitable for three-phase electrical systems.
  • 36 kA breaking capacity at 415 V AC provides effective short-circuit fault interruption.
  • Advanced ABB Ekip Dip LS/I electronic trip unit for precise circuit protection.
  • Long-time overload protection (L) helps protect cables and connected electrical equipment.
  • Selectable short-time (S) or instantaneous (I) protection supports different fault protection requirements.
  • Electronic trip adjustment enables improved coordination between upstream and downstream protective devices.
  • Compact ABB Tmax XT2N160 frame supports efficient use of distribution board space.
  • Designed for integration into ABB Protecta Power distribution systems.
  • Suitable for commercial, industrial and infrastructure electrical installations.

Key Features

  • ABB Protecta Power Devices range.
  • ABB Tmax XT2N moulded case circuit breaker platform.
  • 25 A rated electronic trip unit current.
  • Three-pole (3P) construction.
  • 36 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • Ekip Dip LS/I electronic protection unit.
  • Long-time (L) protection against sustained overload conditions.
  • Short-time (S) protection for short-circuit faults with adjustable delay characteristics.
  • Instantaneous (I) protection for rapid interruption of high-current faults.
  • Selectable short-time or instantaneous protection configuration.
  • XT2N160 frame with a maximum frame rating of 160 A.
  • 100 mm three-pole frame width for compact electrical distribution assemblies.
  • Electronic protection technology with configurable trip settings.
  • Fixed-mounted circuit breaker construction with front terminals.
  • Manual toggle operating mechanism with trip indication and reset functionality.
  • Compatible with appropriately selected ABB Tmax XT2 installation accessories.

Reliable Electronic Circuit Protection for Industrial Electrical Distribution

Moulded case circuit breakers such as the ABB EPX-XT2N-E1-0253 protect electrical installations by automatically interrupting current when overload or short-circuit conditions occur. Its Ekip Dip LS/I electronic trip unit monitors electrical current and applies configurable protection characteristics to help safeguard distribution cables, electrical equipment and connected circuits. Long-time protection responds to sustained overloads, while selectable short-time or instantaneous protection provides the required response to short-circuit faults.

The ABB Tmax XT2 circuit breaker family is designed for reliable performance in modern low-voltage distribution systems. Its compact construction, electronic protection technology and compatibility with suitable ABB installation accessories support integration into commercial and industrial electrical infrastructure. The EPX-XT2N-E1-0253 is particularly suited to installations requiring 25 A three-pole circuit protection and a 36 kA fault-breaking rating at 415 V AC, subject to verification of the operating voltage, prospective fault current and protection coordination requirements.

Typical Applications

  • Commercial and industrial electrical distribution boards.
  • ABB Protecta Power distribution assemblies.
  • Three-phase low-voltage electrical distribution systems.
  • Electrical switchboards and sub-distribution panels.
  • Industrial machinery supply circuits and control panel incomers.
  • Building services and electrical infrastructure installations.
  • Electrical feeder and branch circuit protection.
  • Manufacturing facilities, warehouses and commercial premises.
  • Industrial automation panels requiring electronic circuit protection.
  • Electrical installations requiring coordinated overload and short-circuit protection.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker series Tmax XT
Frame designation XT2N
ABB order code 1SDX253976R1
Product type Moulded case circuit breaker (MCCB)
Rated trip unit current 25 A
Number of poles 3
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 415 V AC
Rated service short-circuit breaking capacity (Ics) 36 kA at 415 V AC
Trip unit type Ekip Dip LS/I
Trip unit technology Electronic
Long-time protection (L) Overload protection
Short-time protection (S) Short-circuit protection with time delay
Instantaneous protection (I) Short-circuit protection without intentional delay
Protection configuration Long-time protection with selectable short-time or instantaneous protection
Frame family XT2N160
Maximum frame rating 160 A
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Three-pole frame width 100 mm
Mounting type Fixed mounting
Terminal arrangement Front terminals
Operating mechanism Manual toggle operation
Application Low-voltage three-phase electrical distribution
Installation Electrical distribution boards and compatible switchgear assemblies
Applicable circuit breaker standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT2N-E1-0253 used for?

The ABB EPX-XT2N-E1-0253 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations. Its electronic trip unit provides configurable protection for three-phase electrical systems.

What is the rated current of the EPX-XT2N-E1-0253?

The circuit breaker has a 25 A rated electronic trip unit current, making it suitable for appropriately designed electrical distribution circuits requiring 25 A protection. It uses the ABB XT2N160 frame, which has a maximum frame rating of 160 A.

What is the breaking capacity of this MCCB?

The EPX-XT2N-E1-0253 has a rated ultimate short-circuit breaking capacity of 36 kA at 415 V AC. Its rated service short-circuit breaking capacity is also 36 kA at 415 V AC. The applicable breaking capacity must be checked against the installation voltage and prospective short-circuit current.

What protection does the Ekip Dip LS/I electronic trip unit provide?

The ABB Ekip Dip LS/I electronic trip unit provides long-time overload protection (L) together with selectable short-time short-circuit protection (S) or instantaneous short-circuit protection (I). These electronic protection functions allow the circuit breaker to be configured for the protection and coordination requirements of the electrical installation.

Where is the ABB EPX-XT2N-E1-0253 typically installed?

This MCCB is typically installed in low-voltage electrical distribution boards, industrial switchboards and compatible ABB Protecta Power assemblies, where three-pole electronic circuit protection is required. Its fixed-mounted construction and front terminal connections support integration into suitable electrical distribution panels.

Trusted by Electrical Engineers and Industrial Installers Worldwide

ABB Tmax XT moulded case circuit breakers are designed to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT2N-E1-0253 combines a 25 A electronic trip unit, three-pole construction and advanced Ekip Dip LS/I protection in a compact circuit breaker suitable for commercial, industrial and infrastructure power distribution applications.