1SDX253962R1 ABB EPX-XT5N-TM6304 630A 4-Pole 36kA TMA MCCB

1SDX253962R1 ABB EPX-XT5N-TM6304 630A 4-Pole 36kA TMA MCCB

ABB EPX-XT5N-TM6304 is a 630 A four-pole moulded case circuit breaker from the Protecta Power range, featuring a 36 kA breaking capacity at 415 V AC and adjustable TMA thermal-magnetic protection for high-current low-voltage electrical distribution systems.

SKU: 1SDX253962R1Alt SKU: EPX-XT5N-TM6304MPN: 1SDX253962R1
Price
List Price £2,450.18 ex VAT
Your Price (ex VAT)
£2,450.18
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,450.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,450.18

Why Choose the ABB EPX-XT5N-TM6304 630A 4-Pole MCCB?

The ABB EPX-XT5N-TM6304 is a robust and reliable 630 A four-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the proven ABB Tmax XT5N circuit breaker platform, it is engineered for commercial, industrial and infrastructure applications requiring dependable high-current electrical circuit protection.

This circuit breaker incorporates a TMA thermal-magnetic trip unit, combining adjustable thermal overload protection with adjustable magnetic short-circuit protection to help safeguard electrical circuits, distribution cables and connected equipment. Its four-pole configuration supports three-phase electrical distribution systems incorporating a neutral conductor, making it suitable for main distribution boards, switchboards and power distribution assemblies.

With a rated current of 630 A and a 36 kA breaking capacity at 415 V AC, the EPX-XT5N-TM6304 provides robust protection for electrical installations requiring reliable fault interruption. Its XT5N630 frame, fixed-mounted construction and front terminal connections support integration into compatible ABB Protecta Power distribution equipment and low-voltage electrical panels.

Key Advantages

  • Reliable 630 A moulded case circuit breaker for high-current low-voltage electrical distribution.
  • Four-pole configuration suitable for three-phase systems incorporating a neutral conductor.
  • 36 kA breaking capacity at 415 V AC provides effective short-circuit fault interruption.
  • Integrated TMA thermal-magnetic protection for overload and short-circuit faults.
  • Adjustable thermal and magnetic protection settings support circuit protection coordination.
  • ABB Tmax XT5N630 frame provides a compact solution for high-current distribution applications.
  • Full-rated neutral protection supports appropriate four-pole distribution applications.
  • Designed for integration into ABB Protecta Power distribution systems.
  • Manual switching and resetting functionality for convenient operation and maintenance.
  • Suitable for commercial, industrial and infrastructure electrical installations.

Key Features

  • ABB Protecta Power Devices range.
  • ABB Tmax XT5N moulded case circuit breaker platform.
  • 630 A rated current.
  • Four-pole (4P) construction.
  • 36 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • TMA thermal-magnetic trip unit providing overload and short-circuit protection.
  • Adjustable thermal overload protection for matching circuit protection requirements.
  • Adjustable magnetic trip threshold for short-circuit protection.
  • XT5N630 frame with a maximum frame rating of 630 A.
  • 100% rated neutral protection for four-pole operation.
  • Fixed-mounted circuit breaker construction with front terminals.
  • Manual toggle operating mechanism with trip indication and reset functionality.
  • Suitable for three-phase low-voltage distribution circuits.
  • Compatible with appropriately selected ABB Tmax XT5 installation accessories.

Reliable Circuit Protection for High-Current Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT5N-TM6304 protect electrical installations by automatically interrupting current when overload or short-circuit conditions occur. The integrated TMA thermal-magnetic trip mechanism uses a thermal element to respond to sustained overloads and a magnetic element to provide rapid tripping during high-current faults, helping reduce the risk of damage to distribution cables, electrical equipment and connected circuits.

The ABB Tmax XT5 circuit breaker family is developed for reliable performance in modern low-voltage distribution systems. Its robust construction, adjustable protection technology and compatibility with suitable ABB installation accessories support integration into commercial and industrial electrical infrastructure. The EPX-XT5N-TM6304 is particularly suited to installations requiring 630 A four-pole circuit protection and a 36 kA fault-breaking rating at 415 V AC, subject to verification of the operating voltage, prospective fault current and installation coordination requirements.

Typical Applications

  • Commercial and industrial main electrical distribution boards.
  • ABB Protecta Power distribution assemblies.
  • Three-phase electrical distribution systems with neutral conductors.
  • Low-voltage main switchboards and power distribution panels.
  • Industrial machinery supply circuits and high-current electrical feeders.
  • Building services and electrical infrastructure installations.
  • Main incomer and sub-distribution circuit protection.
  • Manufacturing facilities, warehouses and large commercial premises.
  • Industrial plant rooms and electrical distribution installations.
  • Infrastructure projects requiring high-current circuit protection.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker series Tmax XT
Frame designation XT5N
ABB order code 1SDX253962R1
Product type Moulded case circuit breaker (MCCB)
Rated current 630 A
Number of poles 4
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 415 V AC
Trip unit type TMA thermal-magnetic
Thermal protection Adjustable overload protection
Thermal adjustment range 441–630 A
Magnetic protection Adjustable instantaneous short-circuit protection
Magnetic trip adjustment range 3150–6300 A
Neutral protection 100% of phase rating
Protection functions Thermal overload and magnetic short-circuit protection
Frame family XT5N630
Maximum frame rating 630 A
Rated operational voltage (series) Up to 690 V AC
Rated frequency 50/60 Hz
Mounting type Fixed mounting
Terminal arrangement Front terminals
Operating mechanism Manual toggle operation
Application Low-voltage electrical distribution
Installation Electrical distribution boards and compatible switchgear assemblies
Applicable circuit breaker standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT5N-TM6304 used for?

The ABB EPX-XT5N-TM6304 is a four-pole moulded case circuit breaker designed to protect high-current low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.

What is the rated current of the EPX-XT5N-TM6304?

The circuit breaker has a 630 A rated current, making it suitable for appropriately designed electrical distribution circuits requiring protection up to 630 A. Its TMA thermal overload setting can be adjusted between 441 A and 630 A.

What is the breaking capacity of this MCCB?

The EPX-XT5N-TM6304 has a rated ultimate short-circuit breaking capacity of 36 kA at 415 V AC. The applicable breaking capacity must be checked against the installation voltage and prospective short-circuit current.

What protection does the TMA thermal-magnetic trip unit provide?

The TMA thermal-magnetic trip unit provides adjustable thermal overload protection and adjustable magnetic short-circuit protection. The magnetic trip threshold can be adjusted within a range of 3150–6300 A, allowing protection settings to be coordinated with the electrical installation.

Where is the ABB EPX-XT5N-TM6304 typically installed?

This MCCB is typically installed in low-voltage main distribution boards, industrial switchboards and compatible ABB Protecta Power assemblies, where high-current four-pole circuit protection is required.

Trusted by Electrical Engineers and Industrial Installers Worldwide

ABB Tmax XT moulded case circuit breakers are designed to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT5N-TM6304 combines a 630 A rating, four-pole construction and adjustable TMA thermal-magnetic protection in a robust circuit breaker suitable for commercial, industrial and infrastructure power distribution applications.