ABB EPX-XT5N-TM6304 is a 630 A four-pole moulded case circuit breaker from the Protecta Power range, featuring a 36 kA breaking capacity at 415 V AC and adjustable TMA thermal-magnetic protection for high-current low-voltage electrical distribution systems.
£2,450.18
The ABB EPX-XT5N-TM6304 is a robust and reliable 630 A four-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the proven ABB Tmax XT5N circuit breaker platform, it is engineered for commercial, industrial and infrastructure applications requiring dependable high-current electrical circuit protection.
This circuit breaker incorporates a TMA thermal-magnetic trip unit, combining adjustable thermal overload protection with adjustable magnetic short-circuit protection to help safeguard electrical circuits, distribution cables and connected equipment. Its four-pole configuration supports three-phase electrical distribution systems incorporating a neutral conductor, making it suitable for main distribution boards, switchboards and power distribution assemblies.
With a rated current of 630 A and a 36 kA breaking capacity at 415 V AC, the EPX-XT5N-TM6304 provides robust protection for electrical installations requiring reliable fault interruption. Its XT5N630 frame, fixed-mounted construction and front terminal connections support integration into compatible ABB Protecta Power distribution equipment and low-voltage electrical panels.
Moulded case circuit breakers such as the ABB EPX-XT5N-TM6304 protect electrical installations by automatically interrupting current when overload or short-circuit conditions occur. The integrated TMA thermal-magnetic trip mechanism uses a thermal element to respond to sustained overloads and a magnetic element to provide rapid tripping during high-current faults, helping reduce the risk of damage to distribution cables, electrical equipment and connected circuits.
The ABB Tmax XT5 circuit breaker family is developed for reliable performance in modern low-voltage distribution systems. Its robust construction, adjustable protection technology and compatibility with suitable ABB installation accessories support integration into commercial and industrial electrical infrastructure. The EPX-XT5N-TM6304 is particularly suited to installations requiring 630 A four-pole circuit protection and a 36 kA fault-breaking rating at 415 V AC, subject to verification of the operating voltage, prospective fault current and installation coordination requirements.
| Product range | Protecta Power Devices |
|---|---|
| Circuit breaker series | Tmax XT |
| Frame designation | XT5N |
| ABB order code | 1SDX253962R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 630 A |
| Number of poles | 4 |
| Rated ultimate short-circuit breaking capacity (Icu) | 36 kA at 415 V AC |
| Trip unit type | TMA thermal-magnetic |
| Thermal protection | Adjustable overload protection |
| Thermal adjustment range | 441–630 A |
| Magnetic protection | Adjustable instantaneous short-circuit protection |
| Magnetic trip adjustment range | 3150–6300 A |
| Neutral protection | 100% of phase rating |
| Protection functions | Thermal overload and magnetic short-circuit protection |
| Frame family | XT5N630 |
| Maximum frame rating | 630 A |
| Rated operational voltage (series) | Up to 690 V AC |
| Rated frequency | 50/60 Hz |
| Mounting type | Fixed mounting |
| Terminal arrangement | Front terminals |
| Operating mechanism | Manual toggle operation |
| Application | Low-voltage electrical distribution |
| Installation | Electrical distribution boards and compatible switchgear assemblies |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
The ABB EPX-XT5N-TM6304 is a four-pole moulded case circuit breaker designed to protect high-current low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.
The circuit breaker has a 630 A rated current, making it suitable for appropriately designed electrical distribution circuits requiring protection up to 630 A. Its TMA thermal overload setting can be adjusted between 441 A and 630 A.
The EPX-XT5N-TM6304 has a rated ultimate short-circuit breaking capacity of 36 kA at 415 V AC. The applicable breaking capacity must be checked against the installation voltage and prospective short-circuit current.
The TMA thermal-magnetic trip unit provides adjustable thermal overload protection and adjustable magnetic short-circuit protection. The magnetic trip threshold can be adjusted within a range of 3150–6300 A, allowing protection settings to be coordinated with the electrical installation.
This MCCB is typically installed in low-voltage main distribution boards, industrial switchboards and compatible ABB Protecta Power assemblies, where high-current four-pole circuit protection is required.
ABB Tmax XT moulded case circuit breakers are designed to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT5N-TM6304 combines a 630 A rating, four-pole construction and adjustable TMA thermal-magnetic protection in a robust circuit breaker suitable for commercial, industrial and infrastructure power distribution applications.