1SDX253960R1 ABB EPX-XT5N-TM4004 400A 4-Pole 36kA TMA Moulded Case Circuit Breaker

1SDX253960R1 ABB EPX-XT5N-TM4004 400A 4-Pole 36kA TMA Moulded Case Circuit Breaker

ABB EPX-XT5N-TM4004 is a 400 A four-pole moulded case circuit breaker with 36 kA breaking capacity at 380–415 V AC, a fully rated neutral and adjustable TMA thermal-magnetic protection for reliable low-voltage electrical distribution.

SKU: 1SDX253960R1Alt SKU: EPX-XT5N-TM4004MPN: 1SDX253960R1
Price
List Price £1,710.26 ex VAT
Your Price (ex VAT)
£1,710.26
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,710.26
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,710.26

Why Choose the ABB EPX-XT5N-TM4004 400A 4-Pole MCCB?

The ABB EPX-XT5N-TM4004 is a high-performance 400 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 36 kA breaking capacity and an adjustable TMA thermal-magnetic trip unit, this circuit breaker delivers dependable protection for commercial, industrial and infrastructure electrical installations.

As part of the ABB Protecta Power Devices range, the EPX-XT5N-TM4004 incorporates proven ABB SACE Tmax XT5N circuit breaker technology. Its thermal-magnetic protection system combines adjustable thermal overload protection with adjustable magnetic short-circuit protection, helping safeguard electrical cables, distribution equipment and connected circuits against excessive current and electrical faults.

With a 400 A rated current, four-pole configuration and 36 kA short-circuit breaking capacity at 380–415 V AC, the EPX-XT5N-TM4004 is suitable for three-phase electrical distribution systems requiring high-current circuit protection. Its XT5N frame, fully rated neutral and compatibility with ABB Protecta Power distribution equipment make it an effective solution for electrical panel builders, contractors and industrial maintenance engineers.

Key Advantages

  • 400 A rated current suitable for high-capacity low-voltage electrical distribution circuits.
  • 36 kA breaking capacity at 380–415 V AC for reliable short-circuit protection.
  • Four-pole configuration suitable for three-phase and neutral electrical distribution systems.
  • Fully rated neutral pole supports applications requiring a neutral current rating equal to the phase current rating.
  • TMA adjustable thermal-magnetic trip unit provides dependable overload and short-circuit protection.
  • Adjustable thermal protection allows protection settings to be coordinated with circuit loading requirements.
  • Adjustable magnetic protection supports effective short-circuit fault protection.
  • ABB SACE Tmax XT5N technology combines robust construction with reliable electrical switching performance.
  • Fixed-mounted design with front terminals supports integration into electrical distribution assemblies.
  • Suitable for installation in ABB Protecta Power distribution systems and compatible switchgear arrangements.

Key Features

  • ABB EPX-XT5N-TM4004 moulded case circuit breaker.
  • 400 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA rated ultimate short-circuit breaking capacity (Icu) at 380–415 V AC.
  • TMA adjustable thermal-magnetic protection release.
  • Adjustable thermal overload protection.
  • Adjustable instantaneous magnetic short-circuit protection.
  • 400–4,000 A thermal-magnetic release designation for the XT5N 400 TMA configuration.
  • 2,000–4,000 A magnetic trip adjustment range.
  • Fully rated neutral (100% In).
  • ABB SACE Tmax XT5N frame with a 400 A rated configuration.
  • Fixed installation with front connection terminals.
  • Suitable for low-voltage power distribution, switching and circuit protection.
  • Compatible with appropriately selected ABB Tmax XT accessories and Protecta Power distribution equipment.

Reliable Circuit Protection for High-Current Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT5N-TM4004 protect electrical distribution circuits against overload currents and short-circuit faults. The integrated TMA thermal-magnetic trip unit uses thermal protection to respond to sustained overload conditions and magnetic protection to respond rapidly to high fault currents. Adjustable protection settings allow electrical engineers to coordinate circuit breaker operation with the characteristics of the installation, connected conductors and downstream equipment.

The ABB SACE Tmax XT5N platform combines high-current electrical protection with robust mechanical construction suitable for modern switchgear assemblies. With its 400 A rating, four-pole switching arrangement, fully rated neutral and 36 kA breaking capacity at 380–415 V AC, the EPX-XT5N-TM4004 supports reliable protection of distribution feeders, switchboard circuits and industrial electrical installations. Its compatibility with ABB Protecta Power systems makes it particularly suitable for panel builders and electrical contractors requiring dependable low-voltage distribution equipment.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial and industrial low-voltage switchboards.
  • Three-phase electrical distribution systems requiring four-pole protection.
  • High-current electrical distribution feeders and sub-distribution circuits.
  • Main and secondary distribution panels in commercial buildings.
  • Industrial machinery and equipment supply circuits.
  • Manufacturing facilities and production environments.
  • Warehouses, logistics facilities and industrial infrastructure.
  • Electrical panel building and switchgear assembly projects.
  • Power distribution systems requiring adjustable thermal-magnetic circuit protection.
  • Electrical installation upgrades, maintenance and refurbishment projects.
  • Three-phase and neutral systems requiring a fully rated neutral pole.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
Series XT5N
ABB order code 1SDX253960R1
Underlying ABB circuit breaker reference 1SDA100385R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 400 A
Number of poles 4
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 380–415 V AC
Trip unit TMA adjustable thermal-magnetic
Thermal protection Adjustable overload protection
Magnetic protection Adjustable instantaneous short-circuit protection
Magnetic adjustment range 2,000–4,000 A
Frame size XT5
Frame rating 400 A
Breaking capacity class N
Neutral rating 100% of rated phase current
Neutral current rating 400 A
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1,000 V
Rated impulse withstand voltage (Uimp) 8 kV
Mounting arrangement Fixed installation
Terminal arrangement Front terminals
Application Low-voltage power distribution and circuit protection
Applicable standard IEC 60947-2

Frequently Asked Questions

What is the ABB EPX-XT5N-TM4004 used for?

The ABB EPX-XT5N-TM4004 is a 400 A four-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial, industrial and infrastructure installations.

What is the rated current of the EPX-XT5N-TM4004?

The circuit breaker has a rated current of 400 A, making it suitable for appropriately designed high-current electrical distribution circuits requiring this rating.

What is the breaking capacity of this ABB MCCB?

The EPX-XT5N-TM4004 has a 36 kA rated ultimate short-circuit breaking capacity at 380–415 V AC. This indicates the prospective short-circuit current the breaker is rated to interrupt under the specified test conditions.

What does TMA mean on the ABB EPX-XT5N-TM4004?

TMA identifies an adjustable thermal-magnetic trip unit. The thermal element provides overload protection, while the magnetic element provides instantaneous short-circuit protection. The adjustable settings allow the protection characteristics to be coordinated with the electrical installation.

Is the ABB EPX-XT5N-TM4004 a four-pole circuit breaker?

Yes. The EPX-XT5N-TM4004 is a four-pole (4P) MCCB designed for three-phase electrical distribution applications requiring four-pole switching and protection. The associated XT5N configuration includes a fully rated neutral pole.

What ABB circuit breaker series does this model belong to?

The EPX-XT5N-TM4004 uses ABB SACE Tmax XT5N circuit breaker technology and belongs to the ABB Protecta Power Devices product range for low-voltage electrical distribution applications.

Can the thermal and magnetic protection settings be adjusted?

Yes. The TMA trip unit provides adjustable thermal overload protection and magnetic short-circuit protection. The corresponding XT5N 400 A TMA configuration has a magnetic adjustment range of 2,000–4,000 A, allowing the instantaneous protection threshold to be configured according to the installation requirements.

Does the ABB EPX-XT5N-TM4004 have a fully rated neutral?

Yes. The corresponding ABB XT5N 400 A four-pole TMA configuration features a 100% rated neutral, meaning the neutral pole is rated for the same 400 A current as the phase poles.

Where is the ABB EPX-XT5N-TM4004 typically installed?

This MCCB is typically installed in low-voltage distribution boards, industrial switchboards and electrical panel assemblies, including compatible ABB Protecta Power distribution systems. Its fixed-mounted construction and front terminals support integration into suitable electrical enclosures.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely specified by electrical engineers, panel builders, industrial maintenance teams and electrical contractors for dependable overload and short-circuit protection. The ABB EPX-XT5N-TM4004 combines a 400 A rating, four-pole configuration, fully rated neutral and 36 kA breaking capacity with adjustable thermal-magnetic protection, making it a practical choice for reliable high-current low-voltage power distribution.