1SDX253956R1 ABB EPX-XT4N-TM2004 200A 4-Pole 36kA TMA Moulded Case Circuit Breaker

1SDX253956R1 ABB EPX-XT4N-TM2004 200A 4-Pole 36kA TMA Moulded Case Circuit Breaker

ABB EPX-XT4N-TM2004 is a 200 A four-pole moulded case circuit breaker with 36 kA breaking capacity at 380–415 V AC and adjustable TMA thermal-magnetic protection, designed for reliable low-voltage electrical distribution systems.

SKU: 1SDX253956R1Alt SKU: EPX-XT4N-TM2004MPN: 1SDX253956R1
Price
List Price £1,159.58 ex VAT
Your Price (ex VAT)
£1,159.58
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,159.58
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,159.58

Why Choose the ABB EPX-XT4N-TM2004 200A 4-Pole MCCB?

The ABB EPX-XT4N-TM2004 is a high-performance 200 A 4-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 36 kA breaking capacity and a TMA adjustable thermal-magnetic trip unit, this circuit breaker delivers dependable protection for commercial, industrial and infrastructure electrical installations.

As part of the ABB Protecta Power distribution range, the EPX-XT4N-TM2004 incorporates proven ABB SACE Tmax XT4N circuit breaker technology. Its thermal-magnetic protection system combines adjustable thermal overload protection with magnetic short-circuit protection, helping protect electrical cables, distribution equipment and connected circuits against excessive current and electrical faults.

With a 200 A rated current, four-pole configuration and 36 kA short-circuit breaking capacity at 380–415 V AC, the EPX-XT4N-TM2004 is suitable for three-phase electrical distribution systems requiring four-pole circuit switching and protection. Its compact XT4 frame and compatibility with Protecta Power distribution equipment make it an effective solution for electrical panel builders, contractors and industrial maintenance engineers.

Key Advantages

  • 200 A rated current for medium-capacity low-voltage electrical distribution circuits.
  • 36 kA breaking capacity at 380–415 V AC for reliable short-circuit protection.
  • Four-pole configuration suitable for three-phase and neutral distribution systems.
  • TMA adjustable thermal-magnetic trip unit provides overload and short-circuit protection.
  • Adjustable thermal protection supports coordination with circuit loading requirements.
  • ABB SACE Tmax XT4N technology provides dependable circuit protection and switching performance.
  • Compact moulded case construction supports efficient installation in electrical distribution assemblies.
  • Suitable for integration into ABB Protecta Power distribution boards and compatible switchgear arrangements.

Key Features

  • ABB EPX-XT4N-TM2004 moulded case circuit breaker.
  • 200 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA rated ultimate short-circuit breaking capacity (Icu) at 380–415 V AC.
  • TMA thermal-magnetic protection release.
  • Adjustable thermal overload protection.
  • Adjustable magnetic short-circuit protection.
  • XT4N frame from the ABB SACE Tmax XT circuit breaker family.
  • Designed for low-voltage electrical distribution and circuit protection.
  • Fixed-installation circuit breaker construction with front connection terminals.
  • Suitable for electrical distribution panels, switchboards and industrial power systems.
  • Compatible with appropriately selected ABB Tmax XT accessories and distribution equipment.

Reliable Circuit Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT4N-TM2004 protect electrical distribution circuits against overload currents and short-circuit faults. The integrated TMA thermal-magnetic trip unit uses thermal protection to respond to sustained overload conditions and magnetic protection to respond rapidly to high fault currents. Adjustable protection settings allow engineers to configure the breaker according to the requirements of the installation and the associated electrical equipment.

The ABB SACE Tmax XT4N platform combines robust electrical protection with a compact mechanical design suitable for modern switchgear assemblies. With its 200 A rating, four-pole switching arrangement and 36 kA breaking capacity at 380–415 V AC, the EPX-XT4N-TM2004 supports reliable protection of distribution feeders, switchboard circuits and industrial electrical installations. Its integration into ABB Protecta Power systems makes it particularly suitable for panel builders and electrical contractors requiring dependable low-voltage distribution equipment.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial and industrial low-voltage switchboards.
  • Three-phase electrical distribution systems requiring four-pole protection.
  • Electrical distribution feeders and sub-distribution circuits.
  • Industrial machinery and equipment supply circuits.
  • Manufacturing facilities and production environments.
  • Commercial buildings and infrastructure electrical installations.
  • Electrical panel building and switchgear assembly projects.
  • Power distribution systems requiring adjustable thermal-magnetic circuit protection.
  • Electrical installation upgrades and maintenance projects.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
Series XT4N
ABB order code 1SDX253956R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 200 A
Number of poles 4
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 380–415 V AC
Trip unit TMA adjustable thermal-magnetic
Thermal protection Adjustable overload protection
Magnetic protection Adjustable instantaneous short-circuit protection
Thermal adjustment range 140–200 A
Magnetic adjustment range 1,000–2,000 A
Frame size XT4
Frame current rating 250 A
Breaking capacity class N
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1,000 V
Rated impulse withstand voltage (Uimp) 8 kV
Mounting arrangement Fixed installation
Terminal arrangement Front terminals
Application Low-voltage power distribution and circuit protection
Applicable standard IEC 60947-2

Frequently Asked Questions

What is the ABB EPX-XT4N-TM2004 used for?

The ABB EPX-XT4N-TM2004 is a 200 A four-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.

What is the rated current of the EPX-XT4N-TM2004?

The circuit breaker has a rated current of 200 A, making it suitable for appropriately designed electrical distribution circuits requiring this current rating.

What is the breaking capacity of this ABB MCCB?

The EPX-XT4N-TM2004 has a 36 kA rated ultimate short-circuit breaking capacity at 380–415 V AC. This indicates the maximum prospective short-circuit current the breaker is rated to interrupt under the specified test conditions.

What does TMA mean on the ABB EPX-XT4N-TM2004?

TMA identifies an adjustable thermal-magnetic trip unit. The thermal element provides overload protection, while the magnetic element provides short-circuit protection. The adjustable settings allow the protection characteristics to be matched to the electrical installation.

Is the ABB EPX-XT4N-TM2004 a four-pole circuit breaker?

Yes. The EPX-XT4N-TM2004 is a four-pole (4P) MCCB designed for applications requiring four-pole switching and circuit protection in three-phase electrical distribution systems.

What ABB circuit breaker series does this model belong to?

The EPX-XT4N-TM2004 uses ABB SACE Tmax XT4N circuit breaker technology and is supplied within the ABB Protecta Power Devices product range for electrical distribution applications.

Can the thermal and magnetic protection settings be adjusted?

Yes. The TMA trip unit provides adjustable thermal overload protection and magnetic short-circuit protection. The corresponding XT4N 200 A TMA configuration provides a thermal adjustment range of 140–200 A and a magnetic adjustment range of 1,000–2,000 A.

Where is the ABB EPX-XT4N-TM2004 typically installed?

This MCCB is typically installed in low-voltage distribution boards, industrial switchboards and electrical panel assemblies, including compatible ABB Protecta Power distribution systems.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB SACE Tmax XT moulded case circuit breakers are trusted by electrical engineers, panel builders, industrial maintenance teams and electrical contractors for dependable overload and short-circuit protection. The ABB EPX-XT4N-TM2004 combines a 200 A rating, four-pole configuration and 36 kA breaking capacity with adjustable thermal-magnetic protection, making it a practical choice for reliable low-voltage power distribution.