1SDX253954R1 ABB EPX-XT4N-TM1604 160A 4-Pole 36kA MCCB Thermal-Magnetic

1SDX253954R1 ABB EPX-XT4N-TM1604 160A 4-Pole 36kA MCCB Thermal-Magnetic

ABB EPX-XT4N-TM1604 is a 160 A four-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and adjustable thermal-magnetic TMA protection, designed for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX253954R1Alt SKU: EPX-XT4N-TM1604MPN: 1SDX253954R1
Price
List Price £1,100.62 ex VAT
Your Price (ex VAT)
£1,100.62
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,100.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,100.62

Why Choose the ABB EPX-XT4N-TM1604 160A 4-Pole MCCB?

The ABB EPX-XT4N-TM1604 is a high-performance 160 A four-pole moulded case circuit breaker (MCCB) designed to protect commercial and industrial electrical distribution circuits against overloads and short circuits. Part of the ABB Protecta Power Devices range, this circuit breaker combines a 36 kA short-circuit breaking capacity with dependable thermal-magnetic protection for demanding low-voltage installations.

Built around the ABB SACE Tmax XT4N platform, the EPX-XT4N-TM1604 incorporates a TMA thermal-magnetic trip unit with adjustable overload and instantaneous short-circuit protection. This allows the breaker to respond to sustained excessive current and high fault currents while providing flexibility for electrical protection coordination. Its robust moulded case construction is suited to professional power distribution environments.

With a 160 A rated current, four-pole configuration and 36 kA breaking capacity, this MCCB is suitable for appropriately designed three-phase distribution systems requiring coordinated switching of phase and neutral conductors. Identified by ABB order code 1SDX253954R1, the EPX-XT4N-TM1604 is intended for integration into compatible ABB Protecta Power panelboards and electrical distribution assemblies.

Key Advantages

  • 160 A rated current for substantial commercial and industrial distribution circuits.
  • Four-pole configuration supports coordinated switching of three phases and a neutral conductor.
  • 36 kA short-circuit breaking capacity for electrical installations with significant prospective fault currents.
  • Thermal-magnetic TMA protection provides overload and instantaneous short-circuit protection.
  • Adjustable thermal overload setting from 112–160 A for the corresponding XT4N TMA configuration.
  • Adjustable magnetic trip setting from 800–1,600 A for fault protection coordination.
  • Fully rated neutral protection in the corresponding XT4N 160 A TMA configuration.
  • Robust ABB SACE Tmax XT4N frame designed for dependable low-voltage circuit protection.
  • 140 mm four-pole width for efficient integration into compatible distribution assemblies.
  • Common operating mechanism provides coordinated switching of all four poles.
  • Part of the ABB Protecta Power Devices range for professional electrical distribution applications.
  • Suitable for compatible ABB panelboards, distribution systems and electrical infrastructure upgrades.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT4N-TM1604 product designation.
  • 160 A rated current for high-capacity low-voltage circuit protection.
  • Four-pole (4P) construction for coordinated conductor switching.
  • 36 kA short-circuit breaking capacity in the specified Protecta Power configuration.
  • TMA thermal-magnetic trip unit for overload and short-circuit protection.
  • 112–160 A thermal adjustment range for the corresponding XT4N 160 A TMA breaker.
  • 800–1,600 A magnetic adjustment range for instantaneous short-circuit protection.
  • 100% rated neutral in the corresponding four-pole XT4N configuration.
  • ABB SACE Tmax XT4N circuit breaker platform.
  • 160 A XT4 frame class with N breaking-capacity designation.
  • 140 mm four-pole device width.
  • Manual operating mechanism with automatic protective tripping.
  • Common operating mechanism for simultaneous four-pole switching.
  • Robust moulded case construction for commercial and industrial electrical environments.
  • Designed for integration into compatible ABB Protecta Power distribution assemblies.

Reliable Four-Pole Protection for Low-Voltage Power Distribution

The ABB EPX-XT4N-TM1604 provides essential protection for low-voltage electrical distribution circuits. Its protective mechanism automatically interrupts the circuit when excessive current conditions exceed the configured trip characteristics. This helps protect conductors and connected equipment against damage caused by sustained overloads and short-circuit faults.

The TMA thermal-magnetic trip unit combines thermal overload protection with instantaneous magnetic short-circuit protection. In the corresponding XT4N 160 A configuration, the thermal setting is adjustable from 112–160 A, while the magnetic setting is adjustable from 800–1,600 A. These settings allow electrical designers and installers to coordinate circuit protection with conductor ratings, connected loads and other protective devices.

The four-pole arrangement supports coordinated switching of three phase conductors and a neutral conductor where required by the installation design. The corresponding XT4N TMA configuration incorporates a 100% rated neutral, providing a fully rated neutral protection arrangement. The suitability of four-pole switching and neutral protection must be assessed in accordance with the earthing system and applicable electrical installation requirements.

The ABB SACE Tmax XT4N platform combines robust mechanical construction with substantial current-carrying capability. The EPX-XT4N-TM1604 provides a 160 A current rating and a 36 kA short-circuit breaking capacity, making it suitable for appropriately designed commercial and industrial distribution circuits. Its 140 mm four-pole width also supports efficient installation within compatible electrical distribution equipment.

As part of the ABB Protecta Power range, the EPX-XT4N-TM1604 is intended for integration into compatible panelboards and distribution assemblies using the correct mounting and connection components. Final selection should consider the prospective short-circuit current, operating voltage, cable ratings, protection settings, neutral requirements and applicable electrical standards.

Typical Applications

  • Commercial and industrial low-voltage electrical distribution.
  • ABB Protecta Power panelboards and compatible assemblies.
  • Three-phase outgoing feeder circuits requiring four-pole switching.
  • Industrial switchboards and distribution panels.
  • Manufacturing and production facilities.
  • Commercial buildings and office complexes.
  • Retail premises and hospitality facilities.
  • Warehouses, logistics centres and distribution buildings.
  • Building services and mechanical plant electrical distribution.
  • Three-phase and neutral circuits requiring appropriately rated neutral protection.
  • Electrical sub-distribution and high-capacity outgoing circuits.
  • Electrical infrastructure upgrades and replacement projects.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power / SACE Tmax XT4N
ABB order code 1SDX253954R1
Corresponding ABB XT4N breaker reference 1SDA068108R1
Product type Moulded case circuit breaker (MCCB)
Rated current 160 A
Number of poles 4
Electrical configuration Three-phase and neutral switching
Short-circuit breaking capacity 36 kA
Protection technology Thermal-magnetic
Trip unit designation TMA
Rated trip unit current 160 A
Thermal overload adjustment range 112–160 A
Magnetic short-circuit adjustment range 800–1,600 A
Neutral protection rating 100% of rated current in the corresponding XT4N configuration
Protection functions Adjustable overload and instantaneous short-circuit protection
Frame family XT4
Frame current class 160 A
Frame performance designation N
Number of switched poles 4
Device width 140 mm
Rated operational voltage of underlying breaker platform Up to 690 V AC
Operating mechanism Manual switching with automatic protective tripping
Corresponding breaker construction Fixed moulded case circuit breaker
Corresponding breaker terminal arrangement Front terminals
Applicable circuit breaker standard IEC 60947-2
Mounting application Compatible electrical distribution assemblies
Application category Low-voltage electrical power distribution
Typical installation ABB Protecta Power panelboards and compatible distribution equipment

Frequently Asked Questions

What is the ABB EPX-XT4N-TM1604 used for?

The ABB EPX-XT4N-TM1604 is a four-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for appropriately designed commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.

What is the rated current of the ABB EPX-XT4N-TM1604?

The circuit breaker has a rated current of 160 A. Its corresponding XT4N thermal-magnetic TMA configuration provides adjustable thermal overload protection from 112–160 A, allowing the protection setting to be coordinated with the electrical circuit.

What is the breaking capacity of this MCCB?

The ABB EPX-XT4N-TM1604 has a specified 36 kA short-circuit breaking capacity. The circuit breaker must be selected with reference to the installation's prospective fault current, operating voltage and applicable protection requirements.

What type of protection does the EPX-XT4N-TM1604 provide?

This MCCB incorporates an adjustable thermal-magnetic (TMA) trip unit. The thermal element provides overload protection, while the magnetic element provides instantaneous short-circuit protection. The corresponding XT4N 160 A TMA configuration supports thermal adjustment from 112–160 A and magnetic adjustment from 800–1,600 A.

What is the advantage of the four-pole configuration?

The four-pole configuration allows coordinated switching of three phase conductors and a neutral conductor where required by the electrical installation design. The corresponding XT4N 160 A TMA configuration includes a 100% rated neutral, supporting applications requiring fully rated neutral protection, subject to the installation's earthing and protection requirements.

Trusted by Electrical Professionals Worldwide

ABB Protecta Power protective devices combine established circuit protection technology with practical electrical distribution solutions. The EPX-XT4N-TM1604 offers a robust 160 A, four-pole XT4N MCCB configuration with adjustable thermal-magnetic TMA protection and a 36 kA breaking capacity, supporting dependable protection in demanding commercial and industrial low-voltage distribution installations.