1SDX253953R1 ABB EPX-XT4N-TM1254 125A 4-Pole 36kA MCCB Thermal-Magnetic

1SDX253953R1 ABB EPX-XT4N-TM1254 125A 4-Pole 36kA MCCB Thermal-Magnetic

ABB EPX-XT4N-TM1254 is a 125 A four-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity, adjustable thermal-magnetic TMA protection and a fully rated neutral, designed for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX253953R1Alt SKU: EPX-XT4N-TM1254MPN: 1SDX253953R1
Price
List Price £1,012.56 ex VAT
Your Price (ex VAT)
£1,012.56
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,012.56
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,012.56

Why Choose the ABB EPX-XT4N-TM1254 125A 4-Pole MCCB?

The ABB EPX-XT4N-TM1254 is a robust and reliable 125 A four-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in commercial and industrial electrical distribution systems. As part of the ABB Protecta Power Devices range, this circuit breaker combines adjustable thermal-magnetic protection technology with a 36 kA short-circuit breaking capacity, making it suitable for demanding low-voltage power distribution applications.

Based on the ABB SACE Tmax XT4N circuit breaker platform, the EPX-XT4N-TM1254 is engineered for dependable electrical protection and integration into compatible distribution assemblies. Its TMA thermal-magnetic trip unit provides adjustable overload and instantaneous short-circuit protection, helping safeguard electrical installations, conductors and connected equipment. The XT4 frame combines robust mechanical construction with flexible protection settings and practical installation capabilities.

With a 125 A rated current, four-pole configuration and 36 kA ultimate short-circuit breaking capacity at 415 V AC, the ABB EPX-XT4N-TM1254 is suitable for appropriately designed three-phase electrical distribution circuits requiring coordinated switching of three phases and a neutral conductor. Identified by ABB order code 1SDX253953R1, this MCCB belongs to the Protecta Power range and is intended for integration into compatible ABB electrical distribution equipment.

Key Advantages

  • Reliable 125 A moulded case circuit breaker for commercial and industrial low-voltage electrical distribution.
  • Four-pole (4P) configuration suitable for three-phase systems requiring coordinated neutral switching.
  • 36 kA short-circuit breaking capacity at 415 V AC for installations with significant prospective fault currents.
  • Integrated thermal-magnetic (TMA) trip unit provides overload and short-circuit protection.
  • Adjustable thermal overload protection with a setting range of 87.5–125 A.
  • Adjustable magnetic short-circuit protection with a setting range of 625–1,250 A.
  • Robust ABB SACE Tmax XT4N frame designed for dependable electrical protection.
  • Fully rated neutral protection with a 100% neutral rating in the corresponding XT4N TMA configuration.
  • 100% rated service short-circuit breaking capacity relative to Icu at 415 V AC.
  • Part of the ABB Protecta Power Devices range for professional electrical distribution applications.
  • Common operating mechanism enables coordinated switching of all four poles.
  • Suitable for installation within compatible ABB Protecta Power panelboards and distribution equipment.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT4N-TM1254 product designation.
  • 125 A rated current for electrical circuit protection.
  • Four-pole (4P) configuration for three-phase and neutral switching applications.
  • 36 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • Thermal-magnetic TMA trip unit for overload and short-circuit protection.
  • 87.5–125 A adjustable thermal overload setting for the 125 A TMA configuration.
  • 625–1,250 A adjustable magnetic trip setting for instantaneous short-circuit protection.
  • 100% rated neutral configuration for protection of the neutral conductor.
  • ABB SACE Tmax XT4N platform with N short-circuit performance classification.
  • XT4 160 A frame class supporting a range of protective current ratings.
  • 140 mm four-pole device width for integration into compatible distribution assemblies.
  • 690 V AC maximum rated operational voltage for the underlying XT4N circuit breaker platform.
  • Manual switching mechanism with automatic protective tripping.
  • Common four-pole operating mechanism for coordinated conductor switching.
  • Robust moulded case construction for commercial and industrial electrical installations.
  • Designed for integration into compatible ABB Protecta Power electrical distribution assemblies.

Reliable Four-Pole Circuit Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT4N-TM1254 provide essential protection within low-voltage electrical distribution systems. They automatically interrupt the electrical supply when overload or short-circuit conditions cause the protective trip mechanism to operate. This helps reduce the risk of excessive conductor heating, electrical equipment damage and disruption caused by electrical faults.

The TMA thermal-magnetic protection system combines two complementary protective functions. The thermal element responds to sustained overload currents, while the magnetic element provides rapid operation during high short-circuit current conditions. For the 125 A XT4N TMA configuration, thermal protection can be adjusted between 87.5–125 A, while magnetic protection can be adjusted between 625–1,250 A. These settings allow the protective response to be coordinated with appropriately designed electrical circuits and connected equipment.

The four-pole configuration provides an important advantage in electrical distribution applications where coordinated switching of three phase conductors and a neutral conductor is required. All four poles operate through a common mechanism, supporting coordinated circuit switching. The corresponding XT4N TMA configuration incorporates a 100% rated neutral, providing a fully rated neutral protection arrangement. Neutral switching and protection requirements must be assessed against the installation earthing system, conductor arrangement and applicable electrical regulations.

The ABB SACE Tmax XT4N platform combines robust construction with dependable protective performance. Although the XT4 frame family accommodates multiple current ratings, the EPX-XT4N-TM1254 uses a 160 A frame class with a 125 A rated thermal-magnetic trip unit. Its 36 kA ultimate and service short-circuit breaking capacities at 415 V AC support installations requiring substantial fault-current protection. Circuit breaker selection must consider prospective fault current, operating voltage, conductor ratings and protection coordination requirements.

As part of the ABB Protecta Power distribution system, the EPX-XT4N-TM1254 is intended for integration into compatible electrical panelboard assemblies using appropriate mounting and connection components. Its 140 mm four-pole width, adjustable thermal-magnetic protection and robust XT4 construction make it a practical choice for electrical contractors, panel builders, facilities engineers and industrial maintenance professionals.

Typical Applications

  • Commercial and industrial electrical distribution systems.
  • ABB Protecta Power panelboards and compatible assemblies.
  • Three-phase outgoing circuits requiring four-pole switching.
  • Industrial low-voltage switchboards and distribution panels.
  • Manufacturing and production facilities.
  • Office buildings and commercial premises.
  • Retail centres and hospitality facilities.
  • Warehouses and logistics buildings.
  • Building services and mechanical plant electrical distribution.
  • Three-phase and neutral distribution circuits requiring fully rated neutral protection.
  • Electrical sub-distribution and appropriately rated feeder circuits.
  • Electrical infrastructure upgrades, maintenance and replacement projects.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power / SACE Tmax XT4N
ABB order code 1SDX253953R1
Corresponding ABB XT4N breaker reference 1SDA068107R1
Product type Moulded case circuit breaker (MCCB)
Rated current 125 A
Number of poles 4
Electrical configuration Three-phase and neutral switching
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 415 V AC
Rated service short-circuit breaking capacity (Ics) 36 kA at 415 V AC
Rated operational voltage (Ue), underlying breaker Up to 690 V AC
Rated insulation voltage (Ui) 1,000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50/60 Hz
Protection technology Thermal-magnetic
Trip unit designation TMA
Rated trip unit current 125 A
Thermal overload adjustment range 87.5–125 A
Magnetic short-circuit adjustment range 625–1,250 A
Neutral protection rating 100% of rated current
Protection functions Adjustable overload and instantaneous short-circuit protection
Frame family XT4
Frame current class 160 A
Frame performance designation N
Number of switched poles 4
Device width 140 mm
Operating mechanism Manual switching with automatic protective tripping
Underlying breaker construction Fixed moulded case circuit breaker
Underlying breaker terminal arrangement Front terminals
Applicable circuit breaker standard IEC 60947-2
Mounting application Compatible electrical distribution assemblies
Application category Low-voltage electrical power distribution
Typical installation ABB Protecta Power panelboards and compatible distribution equipment

Frequently Asked Questions

What is the ABB EPX-XT4N-TM1254 used for?

The ABB EPX-XT4N-TM1254 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.

What is the rated current of the ABB EPX-XT4N-TM1254?

The circuit breaker has a rated current of 125 A. Its thermal-magnetic TMA trip unit provides adjustable overload protection between 87.5–125 A, allowing the protection settings to be coordinated with appropriately designed electrical circuits.

What is the breaking capacity of this MCCB?

The ABB EPX-XT4N-TM1254 has a 36 kA rated ultimate short-circuit breaking capacity at 415 V AC. The corresponding XT4N configuration also provides a rated service short-circuit breaking capacity of 36 kA at 415 V AC. Suitability must be assessed against the prospective fault current and operating conditions of the installation.

What type of protection does the EPX-XT4N-TM1254 provide?

This MCCB incorporates an adjustable thermal-magnetic (TMA) trip unit. The thermal element provides protection against sustained overloads, while the magnetic element provides rapid protection against high short-circuit currents. The 125 A XT4N TMA configuration supports thermal adjustment from 87.5–125 A and magnetic adjustment from 625–1,250 A.

What is the advantage of the four-pole configuration?

The four-pole configuration allows coordinated switching of four conductors, typically three phases and a neutral, where required by the electrical installation design. The corresponding XT4N 125 A TMA configuration includes a 100% rated neutral, making it suitable for three-phase distribution systems requiring fully rated neutral protection, subject to applicable earthing and electrical installation requirements.

Trusted by Electrical Professionals Worldwide

ABB Protecta Power protective devices combine established circuit protection technology with practical electrical distribution solutions. The EPX-XT4N-TM1254 offers a robust 125 A, four-pole XT4N MCCB configuration with adjustable thermal-magnetic TMA protection, a fully rated neutral and a 36 kA breaking capacity, supporting dependable protection in commercial and industrial low-voltage distribution installations.