ABB EPX-XT4N-TM0804 is an 80 A four-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity at 415 V AC and adjustable TMA thermal-magnetic protection, designed for reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems.
£922.84
The ABB EPX-XT4N-TM0804 is a robust and reliable 80 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 36 kA short-circuit breaking capacity and a TMA thermal-magnetic trip unit, this circuit breaker belongs to the ABB Protecta Power Devices range and is based on ABB's established SACE Tmax XT4N circuit breaker platform.
Designed for commercial and industrial electrical installations, the EPX-XT4N-TM0804 combines effective circuit protection with a compact and durable construction suitable for modern power distribution equipment. Its thermal-magnetic protection system responds to sustained overload conditions and high short-circuit currents, helping safeguard electrical cables, connected equipment and distribution infrastructure against potentially damaging electrical faults.
With an 80 A rated current, four-pole configuration and 36 kA breaking capacity, the ABB EPX-XT4N-TM0804 is particularly suitable for three-phase distribution circuits requiring four-pole switching, including applications involving a neutral conductor. Supplied under ABB order code 1SDX253951R1, this MCCB provides a dependable solution for compatible ABB Protecta Power distribution boards, commercial electrical panels and industrial switchgear assemblies.
Moulded case circuit breakers such as the ABB EPX-XT4N-TM0804 protect electrical installations by automatically interrupting current when overload or short-circuit conditions occur. By combining normal circuit switching with protective tripping mechanisms, MCCBs help reduce the risk of damage to electrical cables, distribution equipment and connected installations.
The TMA thermal-magnetic trip unit combines two complementary protection principles. The thermal element responds to sustained overload currents, while the magnetic element provides rapid tripping during high-current short circuits. The 56–80 A adjustable thermal setting range associated with the XT4 80 A TMA configuration allows the overload protection threshold to be selected according to the protected circuit, conductor ratings and manufacturer's installation requirements.
The ABB SACE Tmax XT4N 160 A frame platform provides a compact and robust circuit breaker construction suitable for modern low-voltage distribution applications. The EPX-XT4N-TM0804 uses an 80 A thermal-magnetic trip unit within this frame family, providing four-pole switching and circuit protection for appropriately rated electrical distribution circuits.
The four-pole design is particularly useful in three-phase electrical distribution systems where the neutral conductor must be switched alongside the phase conductors. The exact neutral-pole protection arrangement must be verified against the manufacturer's configuration and the requirements of the electrical installation. Four-pole switching can support suitable isolation arrangements but does not itself provide residual-current or earth-leakage protection.
As part of the ABB Protecta Power Devices range, this MCCB is intended for integration into compatible electrical distribution assemblies. Its 36 kA breaking capacity at 415 V AC makes it suitable for installations where the prospective short-circuit current falls within the breaker's verified interruption capability. The XT4N circuit breaker family supports operation at voltages up to 690 V AC, although the available breaking capacity varies with operating voltage.
| Product group | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT4 / Protecta Power |
| ABB order code | 1SDX253951R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 80 A |
| Number of poles | 4 |
| Pole configuration | 4P |
| Rated ultimate short-circuit breaking capacity (Icu) | 36 kA at 415 V AC |
| Breaking capacity classification | N (normal breaking capacity) |
| Trip unit type | TMA thermal-magnetic |
| Thermal trip setting range | 56–80 A |
| Overload protection | Adjustable thermal trip |
| Short-circuit protection | Magnetic trip |
| Frame family | XT4N |
| Frame rating | 160 A |
| Rated operational voltage (XT4N frame family) | Up to 690 V AC |
| Rated insulation voltage (XT4N frame family) | 1,000 V |
| Rated impulse withstand voltage (XT4N frame family) | 8 kV |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
| Mounting configuration | Fixed-mounted MCCB platform |
| Application | Low-voltage electrical distribution |
| Installation type | Compatible electrical distribution board / switchgear assembly |
| Operating mechanism | Manual toggle-operated circuit breaker |
| Typical electrical system | Three-phase AC distribution with four-pole switching |
The ABB EPX-XT4N-TM0804 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.
The EPX-XT4N-TM0804 has an 80 A rated current. It uses an 80 A thermal-magnetic trip unit within the ABB SACE Tmax XT4N 160 A frame family, providing overcurrent protection for appropriately rated electrical distribution circuits.
The ABB EPX-XT4N-TM0804 has a specified 36 kA short-circuit breaking capacity at 415 V AC. Suitability must be checked against the installation voltage and prospective fault current because the available breaking capacity depends on the applicable rated operating conditions.
TMA thermal-magnetic protection combines a thermal overload protection element with a magnetic short-circuit protection element. The thermal mechanism responds to sustained excessive current, while the magnetic mechanism trips rapidly when a sufficiently high short-circuit current occurs.
Yes. The corresponding ABB XT4N 80 A TMA trip unit provides adjustable thermal overload protection, with a nominal setting range of 56–80 A. The appropriate setting must be selected according to the protected circuit, conductor ratings and manufacturer's installation requirements.
The four-pole (4P) configuration enables simultaneous switching of four conductors, typically the three phase conductors and a neutral conductor in a three-phase distribution system. This makes the MCCB suitable for installations requiring four-pole switching or isolation, subject to the manufacturer's neutral-pole arrangement and applicable electrical regulations.
The 80 A trip rating identifies the circuit breaker's rated protective current, while the 160 A frame rating identifies the maximum current rating of the XT4N 160 frame platform. The EPX-XT4N-TM0804 is an 80 A protective device and must not be treated as a 160 A rated circuit breaker.
The standard TMA thermal-magnetic trip unit provides overload and short-circuit protection rather than residual-current or earth-leakage protection. Where earth-leakage protection is required, a suitable additional protective device or compatible earth-leakage solution must be specified.
This MCCB is typically installed within compatible electrical distribution boards, switchgear assemblies and commercial or industrial distribution panels. It is particularly suitable for ABB Protecta Power installations requiring 80 A four-pole outgoing circuit protection.
The ABB manufacturer order code is 1SDX253951R1. The corresponding product reference is EPX-XT4N-TM0804, identifying the 80 A, four-pole, 36 kA thermal-magnetic MCCB within the ABB Protecta Power Devices range.
ABB Protecta Power circuit protection devices combine established SACE Tmax XT circuit breaker technology with practical integration into modern electrical distribution systems. The EPX-XT4N-TM0804 provides dependable 80 A four-pole thermal-magnetic protection and a 36 kA breaking capacity for appropriately specified commercial and industrial installations requiring reliable low-voltage circuit protection.