1SDX253950R1 ABB EPX-XT4N-TM0634 63A 4P 36kA TMA Moulded Case Circuit Breaker

1SDX253950R1 ABB EPX-XT4N-TM0634 63A 4P 36kA TMA Moulded Case Circuit Breaker

ABB EPX-XT4N-TM0634 (1SDX253950R1) is a 63 A four-pole SACE Tmax XT4N160 moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and thermal-magnetic adjustable protection. Designed for compatible ABB Protecta Power distribution assemblies, it provides overload and short-circuit protection for three-phase outgoing circuits requiring four-pole switching.

SKU: 1SDX253950R1Alt SKU: EPX-XT4N-TM0634MPN: 1SDX253950R1
Price
List Price £839.62 ex VAT
Your Price (ex VAT)
£839.62
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £839.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£839.62

Why Choose the ABB EPX-XT4N-TM0634 63A 4-Pole Moulded Case Circuit Breaker?

The ABB EPX-XT4N-TM0634 is a robust 63 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Built around the established ABB SACE Tmax XT4N160 circuit breaker platform, this protective device combines thermal-magnetic adjustable trip technology, four-pole switching capability and a durable moulded case construction suitable for commercial, industrial and building services installations.

Part of the ABB Protecta Power Devices product group, the EPX-XT4N-TM0634 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its thermal-magnetic adjustable (TMA) trip unit provides protection against sustained overload conditions and short-circuit faults, helping safeguard electrical cables, connected equipment and distribution infrastructure. The four-pole configuration enables coordinated switching of three phase conductors and a neutral conductor where required by the electrical installation design.

With a 63 A rated current, a specified 36 kA short-circuit breaking capacity and a four-pole (4P) construction, the EPX-XT4N-TM0634 is an effective solution for three-phase outgoing feeders, commercial distribution circuits and industrial electrical installations requiring neutral switching. Its 140 mm nominal device width supports efficient use of space within compatible electrical distribution boards.

Identified by ABB order code 1SDX253950R1, the EPX-XT4N-TM0634 provides electrical contractors, consulting engineers, panel builders and facilities managers with a clearly specified protective device for projects requiring reliable 63 A circuit protection and four-pole switching.

Key Advantages

  • 63 A rated current for dependable protection of appropriately designed outgoing electrical circuits.
  • 36 kA short-circuit breaking capacity in the specified ABB Protecta Power application.
  • Four-pole (4P) construction enables coordinated switching of three phase conductors and a neutral conductor.
  • Thermal-magnetic adjustable (TMA) trip unit provides protection against overload and short-circuit conditions.
  • Adjustable thermal overload protection supports coordination with appropriately rated cables and connected equipment.
  • Based on the established ABB SACE Tmax XT4N160 platform.
  • 160 A frame platform provides a robust foundation for the 63 A protective device.
  • 140 mm nominal width helps optimise distribution board layouts.
  • Designed for installation within compatible ABB Protecta Power distribution assemblies.
  • Suitable for three-phase circuits where neutral disconnection is required by the installation design.
  • Robust moulded case construction supports dependable performance in demanding electrical environments.
  • Suitable for new installations, distribution board upgrades and commercial or industrial electrical projects.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT4N-TM0634 product designation.
  • ABB order code 1SDX253950R1.
  • ABB SACE Tmax XT4N160 circuit breaker platform.
  • 63 A rated current for outgoing circuit protection.
  • 160 A frame rating within the XT4N160 platform.
  • 36 kA specified short-circuit breaking capacity for compatible Protecta Power applications.
  • Four-pole (4P) configuration for coordinated switching of four conductors.
  • Thermal-magnetic adjustable (TMA) trip configuration for overload and short-circuit protection.
  • Adjustable thermal protection responds to sustained excessive current.
  • Magnetic short-circuit protection provides rapid operation during high-current faults.
  • 140 mm nominal device width for efficient distribution board installation.
  • Manual operating mechanism for circuit switching and isolation when correctly installed.
  • Compatible with appropriate ABB Protecta Power mounting and connection arrangements.
  • Suitable for commercial, industrial and building services electrical distribution systems.

Dependable 63A Four-Pole Circuit Protection for Commercial and Industrial Installations

The ABB EPX-XT4N-TM0634 63 A MCCB is designed to help maintain the safety and reliability of low-voltage electrical distribution networks. Moulded case circuit breakers automatically interrupt current when abnormal operating conditions occur, providing essential protection for cables, distribution equipment and connected electrical loads.

The thermal-magnetic adjustable (TMA) trip unit combines two complementary protection functions. The thermal element responds to sustained overload conditions, helping prevent excessive heating of conductors and electrical equipment. The magnetic element responds rapidly to short-circuit faults, interrupting fault current to help limit damage to the protected electrical circuit.

For electrical engineers and panel builders, thermal-magnetic protection offers a practical solution where dependable overload and short-circuit protection is required without the additional complexity of an electronic trip unit. The thermal adjustment capability supports appropriate coordination with the current-carrying capacity of the protected conductors. The exact setting range and magnetic operating characteristics must be confirmed against the release fitted to the particular circuit breaker.

The four-pole configuration is particularly useful in three-phase electrical distribution systems requiring coordinated switching of the neutral conductor alongside the three phase conductors. This may be relevant in commercial distribution boards, industrial installations and building services systems where neutral disconnection forms part of the electrical design. Neutral switching does not automatically establish the level of neutral overcurrent protection, which depends on the specific circuit breaker configuration.

Based on the ABB SACE Tmax XT4N160 platform, the EPX-XT4N-TM0634 combines a robust circuit breaker construction with a 63 A rated current and specified 36 kA breaking capacity. The four-pole device has a nominal width of 140 mm, helping engineers plan compact and efficient distribution board layouts.

Correct selection and installation should consider the system operating voltage, prospective short-circuit current, cable sizing, protective device coordination, neutral switching requirements and the compatibility of the distribution assembly. The applicable breaking capacity and trip settings should be verified against the relevant ABB technical documentation before installation and commissioning.

Typical Applications

  • ABB Protecta Power distribution boards requiring 63 A four-pole MCCB protection.
  • Commercial building electrical distribution and outgoing feeder circuits.
  • Industrial electrical panels supplying appropriately rated three-phase loads.
  • Three-phase sub-distribution systems requiring neutral switching.
  • Building services installations supplying mechanical and electrical plant.
  • Manufacturing facilities and workshop electrical distribution networks.
  • Warehouses and logistics centres with three-phase power distribution.
  • Office buildings and retail premises with dedicated outgoing distribution circuits.
  • Electrical distribution board upgrades using compatible ABB Protecta Power equipment.
  • Switchboard manufacturing and panel-building projects requiring a 63 A, 4P, 36 kA thermal-magnetic MCCB.

Technical Specifications

Product group Protecta Power Devices
Product range SACE Tmax XT
Circuit breaker platform XT4N160
Model / SKU EPX-XT4N-TM0634
ABB order code 1SDX253950R1
Product type Moulded case circuit breaker (MCCB)
Rated current 63 A
Frame rating 160 A
Short-circuit breaking capacity 36 kA (specified Protecta Power application)
Number of poles 4
Pole configuration Four-pole (4P)
Trip unit designation TMA
Trip unit type Thermal-magnetic adjustable
Thermal protection Adjustable overload protection
Magnetic protection Short-circuit protection
Protection functions Overload and short-circuit protection
Thermal adjustment range Refer to the fitted ABB TMA release documentation
Magnetic trip setting Refer to the fitted ABB TMA release documentation
Neutral switching Four-pole construction
Neutral protection Dependent on the specific fitted release and pole arrangement
Applicable circuit breaker standard IEC 60947-2
Nominal device width 140 mm
Installation type Fixed installation within a compatible distribution assembly
Mounting compatibility ABB Protecta Power, subject to appropriate mounting and connection arrangements
Electrical application Three-phase low-voltage power distribution
Typical use Outgoing feeder and sub-distribution circuit protection

Frequently Asked Questions

What is the ABB EPX-XT4N-TM0634 used for?

The ABB EPX-XT4N-TM0634 is a 63 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is intended for compatible ABB Protecta Power distribution assemblies and is suitable for appropriately designed three-phase outgoing circuits requiring four-pole switching.

What are the rated current and breaking capacity of the EPX-XT4N-TM0634?

The EPX-XT4N-TM0634 has a 63 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It uses the ABB SACE Tmax XT4N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be checked against the installation operating voltage and prospective fault current.

What does TMA mean on the ABB EPX-XT4N-TM0634?

TMA stands for Thermal-Magnetic Adjustable. The thermal element provides overload protection, while the magnetic element responds to short-circuit faults. The adjustable thermal protection supports coordination with appropriately rated cables and electrical equipment. Exact adjustment ranges and magnetic trip characteristics should be confirmed against the ABB documentation for the fitted release.

What is the benefit of a four-pole MCCB compared with a three-pole MCCB?

A four-pole (4P) MCCB provides an additional pole for the neutral conductor, enabling coordinated switching of three phase conductors and neutral where required by the electrical design. A three-pole MCCB switches the three phase conductors without a dedicated neutral pole. Neutral overcurrent protection depends on the specific four-pole circuit breaker configuration and must be verified separately.

Where can the ABB EPX-XT4N-TM0634 be installed?

The breaker is intended for installation within compatible ABB Protecta Power distribution boards, using the appropriate mounting and connection arrangements. The ABB XT4 four-pole platform has a nominal width of 140 mm. Installation should be carried out by a competent electrical professional, with the protective device selected and configured to suit the circuit design and applicable electrical regulations.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are established components in low-voltage electrical distribution, providing dependable protection for commercial and industrial installations. The ABB EPX-XT4N-TM0634 combines a 63 A rated current, four-pole switching, specified 36 kA short-circuit breaking capacity and thermal-magnetic adjustable protection in a robust device intended for compatible ABB Protecta Power distribution systems.