1SDX253949R1 ABB EPX-XT4N-TM0504 50A 4P 36kA TMA Moulded Case Circuit Breaker

1SDX253949R1 ABB EPX-XT4N-TM0504 50A 4P 36kA TMA Moulded Case Circuit Breaker

ABB EPX-XT4N-TM0504 (1SDX253949R1) is a 50 A four-pole SACE Tmax XT4N160 moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and thermal-magnetic adjustable protection. Designed for compatible ABB Protecta Power electrical distribution assemblies, it provides overload and short-circuit protection for three-phase outgoing circuits requiring four-pole switching.

SKU: 1SDX253949R1Alt SKU: EPX-XT4N-TM0504MPN: 1SDX253949R1
Price
List Price £839.62 ex VAT
Your Price (ex VAT)
£839.62
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £839.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£839.62

Why Choose the ABB EPX-XT4N-TM0504 50A 4-Pole Moulded Case Circuit Breaker?

The ABB EPX-XT4N-TM0504 is a high-quality 50 A four-pole moulded case circuit breaker (MCCB) designed to deliver reliable overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT4N160 circuit breaker platform, this protective device combines robust construction, thermal-magnetic protection technology and four-pole switching capability for commercial, industrial and building services applications.

As part of the ABB Protecta Power Devices product group, the EPX-XT4N-TM0504 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its thermal-magnetic adjustable (TMA) trip configuration provides protection against sustained overload conditions and short-circuit faults, helping safeguard electrical cables, connected equipment and distribution infrastructure. The four-pole design supports coordinated switching of three phase conductors and a neutral conductor where required by the electrical installation.

With a 50 A rated current, a specified 36 kA short-circuit breaking capacity and a four-pole (4P) configuration, the EPX-XT4N-TM0504 is suitable for three-phase outgoing circuits requiring reliable MCCB protection and neutral switching. Its 140 mm nominal device width provides a compact installation footprint within compatible distribution assemblies, making it a practical choice for electrical contractors, panel builders, switchboard manufacturers and facilities engineers.

Identified by ABB order code 1SDX253949R1, this circuit breaker offers a clearly specified solution for electrical distribution projects where current rating, pole configuration, short-circuit performance and compatibility with ABB Protecta Power equipment are essential selection criteria.

Key Advantages

  • 50 A rated current provides dependable protection for appropriately designed outgoing distribution circuits.
  • 36 kA short-circuit breaking capacity in the specified ABB Protecta Power application.
  • Four-pole (4P) configuration supports coordinated switching of three phase conductors and a neutral conductor.
  • Thermal-magnetic adjustable (TMA) trip technology provides overload and short-circuit protection.
  • Adjustable thermal protection supports coordination with appropriately rated cables and connected equipment.
  • Based on the established ABB SACE Tmax XT4N160 platform.
  • 160 A frame platform provides a robust foundation for the 50 A protective device.
  • 140 mm nominal device width supports efficient distribution board layouts.
  • Designed for use within compatible ABB Protecta Power distribution assemblies.
  • Suitable for three-phase circuits where neutral disconnection forms part of the installation design.
  • Robust moulded case construction helps support dependable operation in demanding electrical environments.
  • Suitable for new installations, distribution board upgrades and commercial or industrial electrical projects.

Key Features

  • Manufacturer: ABB.
  • Product designation: EPX-XT4N-TM0504.
  • ABB order code: 1SDX253949R1.
  • Product group: Protecta Power Devices.
  • Circuit breaker series: ABB SACE Tmax XT.
  • Circuit breaker platform: XT4N160.
  • Rated current: 50 A.
  • Frame rating: 160 A.
  • Specified breaking capacity: 36 kA.
  • Number of poles: Four.
  • Trip configuration: Thermal-magnetic adjustable (TMA).
  • Overload protection: Thermal trip element.
  • Short-circuit protection: Magnetic trip element.
  • Nominal device width: 140 mm.
  • Switching arrangement: Four-pole operation for suitable three-phase and neutral circuits.
  • Installation: Compatible ABB Protecta Power distribution assembly.
  • Application: Low-voltage commercial and industrial electrical distribution.

Dependable 50A Four-Pole Circuit Protection for Commercial and Industrial Installations

The ABB EPX-XT4N-TM0504 50 A MCCB is designed to help maintain the safety and reliability of low-voltage electrical distribution networks. Moulded case circuit breakers protect electrical circuits by interrupting current when abnormal operating conditions occur. In this thermal-magnetic configuration, the thermal element responds to sustained overloads, while the magnetic element provides rapid operation under short-circuit conditions.

The thermal-magnetic adjustable (TMA) trip configuration offers a practical protection solution for electrical engineers who require dependable circuit protection without the complexity of an electronic trip unit. Thermal protection can support coordination with cable current-carrying capacity and connected electrical loads, while magnetic protection helps interrupt high fault currents before excessive thermal and mechanical stresses develop within the electrical installation.

The four-pole design is an important advantage where the installation requires coordinated switching of the three phase conductors and the neutral conductor. This can be relevant in commercial distribution boards, building services installations and other appropriately designed three-phase systems. Neutral switching and neutral overcurrent protection are not identical functions; the specific neutral protection arrangement must be confirmed for the fitted breaker configuration.

The ABB SACE Tmax XT4N160 platform provides a robust moulded case design for low-voltage distribution applications. The EPX-XT4N-TM0504 uses this platform in a 50 A rated configuration, offering the benefits of the XT4 construction while protecting circuits selected for a 50 A protective device.

Its specified 36 kA short-circuit breaking capacity makes the device suitable for installations where the prospective fault current falls within the breaker rating at the applicable operating voltage. The 140 mm nominal width supports efficient use of space within compatible ABB Protecta Power distribution assemblies.

When selecting the EPX-XT4N-TM0504, the electrical designer should verify the installation operating voltage, prospective short-circuit current, conductor sizing, thermal and magnetic trip settings, neutral requirements and coordination with upstream and downstream protective devices. Correct selection of ABB mounting and connection accessories is also essential for reliable installation.

Typical Applications

  • ABB Protecta Power distribution boards requiring 50 A four-pole MCCB protection.
  • Commercial electrical installations with three-phase outgoing distribution circuits.
  • Industrial distribution panels supplying appropriately rated electrical loads.
  • Three-phase sub-distribution systems where neutral switching is required.
  • Building services installations supplying mechanical and electrical plant.
  • Manufacturing and workshop facilities requiring dependable circuit protection.
  • Warehouses and logistics buildings with three-phase power distribution infrastructure.
  • Commercial premises and offices with dedicated outgoing electrical feeders.
  • Distribution board refurbishment projects using compatible ABB Protecta Power equipment.
  • Electrical panel-building projects requiring a 50 A, 4P, 36 kA thermal-magnetic MCCB.

Technical Specifications

Product group Protecta Power Devices
Product range SACE Tmax XT
Circuit breaker platform XT4N160
Model / SKU EPX-XT4N-TM0504
ABB order code 1SDX253949R1
Product type Moulded case circuit breaker (MCCB)
Rated current 50 A
Frame rating 160 A
Short-circuit breaking capacity 36 kA (specified Protecta Power application)
Number of poles 4
Pole configuration Four-pole (4P)
Trip unit designation TMA
Trip unit type Thermal-magnetic adjustable
Overload protection Thermal
Short-circuit protection Magnetic
Protection functions Overload and short-circuit protection
Thermal adjustment Subject to the characteristics of the fitted TMA release
Magnetic trip characteristics Refer to the fitted ABB trip release documentation
Neutral switching Four-pole construction
Neutral protection Dependent on the specific fitted release and pole arrangement
Applicable circuit breaker standard IEC 60947-2
Nominal device width 140 mm
Installation type Fixed installation within a compatible distribution assembly
Mounting compatibility ABB Protecta Power, subject to the appropriate mounting and connection arrangement
Electrical application Three-phase low-voltage power distribution
Typical use Outgoing feeder and sub-distribution circuit protection

Frequently Asked Questions

What is the ABB EPX-XT4N-TM0504 used for?

The ABB EPX-XT4N-TM0504 is a 50 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is intended for compatible ABB Protecta Power distribution assemblies and is suitable for appropriately designed three-phase outgoing circuits requiring four-pole switching.

What are the current rating and breaking capacity of the EPX-XT4N-TM0504?

The EPX-XT4N-TM0504 has a 50 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It uses the ABB SACE Tmax XT4N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be checked against the installation voltage and prospective fault current.

What does TMA mean on the ABB EPX-XT4N-TM0504?

TMA stands for Thermal-Magnetic Adjustable. The thermal element provides overload protection, while the magnetic element responds to short-circuit faults. This combination provides dependable protection for electrical distribution circuits. Exact thermal adjustment limits and magnetic trip characteristics should be confirmed against the ABB documentation for the specific fitted release.

What is the benefit of choosing a four-pole MCCB instead of a three-pole MCCB?

A four-pole (4P) MCCB provides an additional pole for the neutral conductor, allowing coordinated switching of three phase conductors and neutral where required by the electrical design. A three-pole MCCB switches only the three phase conductors. The neutral protection characteristics of a four-pole device depend on its specific configuration and should be verified before installation.

Where can the ABB EPX-XT4N-TM0504 be installed?

The breaker is intended for installation in compatible ABB Protecta Power distribution boards, using the appropriate mounting and connection arrangements. The ABB XT4 four-pole platform has a nominal width of 140 mm. Installation should be carried out by a competent electrical professional, with the protective device selected and configured to suit the circuit design and applicable electrical regulations.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are established components in low-voltage electrical distribution, offering dependable protection for commercial and industrial installations. The ABB EPX-XT4N-TM0504 combines a 50 A rated current, four-pole switching, specified 36 kA short-circuit breaking capacity and thermal-magnetic adjustable protection in a robust device designed for compatible ABB Protecta Power distribution systems.