ABB EPX-XT2N-TM1254 is a 125 A four-pole 36 kA TMA thermal-magnetic moulded case circuit breaker from the Protecta Power Devices range, designed for adjustable overload and short-circuit protection in low-voltage electrical distribution systems.

SKU: 1SDX253704R1Alt SKU: EPX-XT2N-TM1254MPN: 1SDX253704R1
Price
List Price £796.42 ex VAT
Your Price (ex VAT)
£796.42
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £796.42
Trade pricing is personalised to your account

Manufacturer Lead Time

£796.42

Why Choose the ABB EPX-XT2N-TM1254 125A 4-Pole MCCB?

The ABB EPX-XT2N-TM1254 is a robust and compact 125 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the established ABB SACE Tmax XT2N circuit breaker platform, it offers reliable circuit protection for commercial, industrial and building infrastructure applications.

This circuit breaker incorporates TMA thermal-magnetic protection technology, combining thermal overload protection with magnetic short-circuit protection. Its four-pole construction supports the switching and isolation of three-phase circuits incorporating a neutral conductor. The XT2N platform is designed to provide effective electrical protection while maintaining a compact footprint within modern distribution boards and electrical panel assemblies.

With a rated current of 125 A, a four-pole configuration and a 36 kA short-circuit breaking capacity at 415 V AC, the EPX-XT2N-TM1254 is suitable for protecting outgoing feeders and distribution circuits in demanding electrical installations. Its compact 120 mm-wide XT2 frame enables space-efficient integration into compatible ABB Protecta Power distribution boards and low-voltage electrical enclosures.

Key Advantages

  • Reliable 125 A moulded case circuit breaker for commercial and industrial electrical distribution.
  • Four-pole configuration suitable for three-phase systems incorporating a neutral conductor.
  • 36 kA breaking capacity at 415 V AC for protection against high prospective short-circuit currents.
  • TMA thermal-magnetic trip unit provides overload and short-circuit protection.
  • Adjustable thermal overload protection supports coordination with the protected circuit.
  • Compact ABB Tmax XT2N frame with a nominal width of 120 mm.
  • Designed for integration into ABB Protecta Power distribution systems.
  • 100% rated neutral protection on the corresponding XT2N 125 A four-pole TMA configuration.
  • Manual switching and isolation functionality supports electrical maintenance procedures.
  • Established ABB circuit breaker technology helps provide dependable operation in low-voltage distribution installations.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB SACE Tmax XT2N moulded case circuit breaker platform.
  • 125 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • TMA thermal-magnetic protection for overload and short-circuit faults.
  • Adjustable thermal trip setting for circuit protection coordination.
  • 1250 A nominal magnetic trip setting on the corresponding XT2N TMA configuration.
  • XT2N 160 A frame family.
  • 120 mm nominal width for compact installation.
  • Four-pole construction with 100% neutral rating on the corresponding ABB breaker configuration.
  • Fixed mounting arrangement with manual front-operated switching mechanism.
  • Compatible with appropriately selected ABB Tmax XT2 accessories and installation components.
  • Designed for installation within compatible low-voltage electrical distribution assemblies.

Reliable Thermal-Magnetic Protection for Electrical Distribution

Moulded case circuit breakers such as the ABB EPX-XT2N-TM1254 protect electrical installations by automatically interrupting current when overload or short-circuit conditions occur. The thermal protection element responds to sustained excessive current, helping prevent overheating of cables and connected equipment. The magnetic protection element provides rapid operation during high-current faults, helping limit potential equipment damage and improve the reliability of electrical distribution systems.

The ABB SACE Tmax XT2N platform combines compact construction with established circuit protection technology. Its adjustable thermal protection allows the breaker to be configured within the supported setting range to suit the protected circuit. The four-pole arrangement provides coordinated switching of three phase conductors and a neutral conductor, while the compact frame supports efficient installation in distribution boards where available space is limited. Correct selection of protective settings, cable ratings and short-circuit coordination remains essential for safe and effective operation.

Typical Applications

  • ABB Protecta Power distribution boards and panelboard assemblies.
  • Commercial building low-voltage electrical distribution.
  • Industrial electrical distribution panels and switchboards.
  • Three-phase distribution circuits requiring four-pole protection and isolation.
  • Outgoing feeder protection in main and sub-distribution boards.
  • Electrical control panels and industrial machinery supply circuits.
  • Building services, mechanical plant and infrastructure distribution systems.
  • Commercial premises, offices, warehouses and retail electrical installations.
  • Low-voltage power distribution systems requiring compact 125 A thermal-magnetic MCCBs.

Technical Specifications

Product range Protecta Power Devices
Series SACE Tmax XT2
ABB order code 1SDX253704R1
Product type Moulded case circuit breaker (MCCB)
Frame designation XT2N
Frame size 160 A
Rated current (In) 125 A
Number of poles 4
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 415 V AC
Trip unit type TMA thermal-magnetic
Thermal protection setting range 87.5–125 A
Magnetic trip setting 1250 A
Neutral protection 100% of rated current on the corresponding XT2N TMA configuration
Protection functions Overload and short-circuit protection
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Electrical system Low-voltage AC distribution
Mounting arrangement Fixed installation
Nominal width 120 mm
Operating mechanism Manual toggle operation
Application Circuit protection, switching and isolation
Product family standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT2N-TM1254 used for?

The ABB EPX-XT2N-TM1254 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial distribution boards, including compatible ABB Protecta Power assemblies.

What is the rated current of the EPX-XT2N-TM1254?

The circuit breaker has a 125 A rated current and belongs to the ABB Tmax XT2N 160 A frame family. The frame rating identifies the current class of the circuit breaker platform rather than the rated current of this individual device.

What is the breaking capacity of this ABB MCCB?

The EPX-XT2N-TM1254 has a 36 kA rated ultimate short-circuit breaking capacity at 415 V AC. The prospective short-circuit current and applicable operating voltage must be considered when selecting the breaker for an electrical installation.

What type of protection does the EPX-XT2N-TM1254 provide?

The breaker incorporates a TMA thermal-magnetic trip unit. The thermal element provides adjustable overload protection, while the magnetic element responds to short-circuit faults. The corresponding XT2N 125 A TMA configuration has a thermal adjustment range of 87.5–125 A and a nominal magnetic trip setting of 1250 A.

What does the four-pole configuration mean?

The four-pole (4P) configuration provides switching of three phase conductors and a neutral conductor, making the breaker suitable for appropriately designed three-phase distribution systems requiring four-pole isolation. The corresponding XT2N 125 A TMA configuration provides neutral protection rated at 100% of the phase current.