1SDX253702R1 ABB EPX-XT2N-TM0804 80A 4-Pole 36kA MCCB Thermal-Magnetic

1SDX253702R1 ABB EPX-XT2N-TM0804 80A 4-Pole 36kA MCCB Thermal-Magnetic

ABB EPX-XT2N-TM0804 is an 80 A four-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and thermal-magnetic TMA protection, designed for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX253702R1Alt SKU: EPX-XT2N-TM0804MPN: 1SDX253702R1
Price
List Price £646.45 ex VAT
Your Price (ex VAT)
£646.45
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £646.45
Trade pricing is personalised to your account

Manufacturer Lead Time

£646.45

Why Choose the ABB EPX-XT2N-TM0804 80A 4-Pole MCCB?

The ABB EPX-XT2N-TM0804 is a compact and reliable 80 A four-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in commercial and industrial electrical distribution systems. As part of the ABB Protecta Power Devices range, this circuit breaker combines thermal-magnetic protection technology with a 36 kA short-circuit breaking capacity, making it suitable for demanding low-voltage power distribution applications.

Based on the ABB SACE Tmax XT2N circuit breaker platform, the EPX-XT2N-TM0804 is designed for dependable circuit protection and integration into compatible electrical distribution assemblies. Its TMA thermal-magnetic trip unit provides protection against sustained overload conditions and high short-circuit currents, helping safeguard electrical installations, conductors and connected equipment. The compact XT2 frame combines reliable protective performance with practical installation flexibility.

With an 80 A rated current, four-pole configuration and 36 kA breaking capacity, the ABB EPX-XT2N-TM0804 is suitable for appropriately designed three-phase electrical distribution circuits requiring four-pole switching. Identified by ABB order code 1SDX253702R1, this MCCB belongs to the Protecta Power range and is intended for use with compatible ABB electrical distribution equipment.

Key Advantages

  • Reliable 80 A moulded case circuit breaker for low-voltage electrical distribution systems.
  • Four-pole (4P) configuration suitable for three-phase electrical systems requiring coordinated neutral switching.
  • 36 kA short-circuit breaking capacity for installations with significant prospective fault currents.
  • Integrated thermal-magnetic (TMA) protection against overloads and short circuits.
  • Compact ABB SACE Tmax XT2N frame designed for dependable electrical protection.
  • 120 mm four-pole device width helps optimise space within compatible distribution assemblies.
  • Part of the ABB Protecta Power Devices range for commercial and industrial electrical installations.
  • Common operating mechanism enables coordinated switching of all four poles.
  • Suitable for integration into compatible ABB Protecta Power panelboards and electrical distribution equipment.
  • Automatic protective tripping helps reduce the risk of electrical equipment damage and excessive conductor heating.
  • Thermal-magnetic protection provides dependable operation without requiring an electronic trip unit.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT2N-TM0804 product designation.
  • 80 A rated current for electrical circuit protection.
  • Four-pole (4P) configuration for coordinated switching of three phases and a neutral conductor where applicable.
  • 36 kA short-circuit breaking capacity in the specified Protecta Power configuration.
  • Thermal-magnetic TMA trip unit for overload and short-circuit protection.
  • Adjustable thermal and magnetic protection within the capabilities of the TMA trip unit.
  • ABB SACE Tmax XT2N platform with N breaking-capacity classification.
  • XT2 160 A frame class supporting a range of circuit breaker current ratings.
  • Thermal trip element responds to sustained overload conditions.
  • Magnetic trip element provides rapid operation during high short-circuit current conditions.
  • Manual switching mechanism with automatic protective tripping.
  • 120 mm four-pole device width for compact distribution panel installation.
  • Robust moulded case construction suitable for commercial and industrial electrical environments.
  • Designed for installation within compatible ABB Protecta Power electrical distribution assemblies.

Reliable Four-Pole Circuit Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT2N-TM0804 provide essential protection within low-voltage electrical distribution systems. They automatically interrupt the electrical supply when overload or short-circuit conditions cause the protective trip mechanism to operate. This helps reduce the risk of excessive conductor heating, electrical equipment damage and disruption caused by electrical faults.

The TMA thermal-magnetic protection system combines two complementary protective functions. The thermal element responds to sustained overload currents, while the magnetic element provides rapid operation during high short-circuit current conditions. Adjustable protection settings within the TMA design support coordination with appropriately designed electrical circuits and connected equipment.

The four-pole configuration provides an important advantage in electrical distribution applications where coordinated switching of three phase conductors and a neutral conductor is required. All four poles operate through a common mechanism, supporting simultaneous circuit switching. The suitability of neutral switching and the required neutral protection arrangement must be assessed against the installation earthing system and applicable electrical regulations.

The ABB SACE Tmax XT2N platform combines compact construction with dependable protective performance. Although the XT2 frame family accommodates current ratings up to 160 A, the EPX-XT2N-TM0804 is specifically rated at 80 A. Its 36 kA breaking capacity makes it suitable for appropriately designed installations requiring substantial short-circuit protection. Circuit breaker selection must consider the prospective fault current, operating voltage, conductor ratings and protection coordination requirements.

As part of the ABB Protecta Power distribution system, the EPX-XT2N-TM0804 is intended for integration into compatible electrical panelboard assemblies using appropriate mounting and connection components. Its compact 120 mm four-pole width, thermal-magnetic protection and robust XT2 construction make it a practical choice for electrical contractors, panel builders, facilities engineers and industrial maintenance professionals.

Typical Applications

  • Commercial and industrial electrical distribution systems.
  • ABB Protecta Power panelboards and compatible assemblies.
  • Three-phase outgoing circuits requiring four-pole switching.
  • Industrial low-voltage switchboards and distribution panels.
  • Manufacturing and production facilities.
  • Office buildings and commercial premises.
  • Retail centres and hospitality facilities.
  • Warehouses and logistics buildings.
  • Building services and mechanical plant electrical distribution.
  • Three-phase and neutral distribution circuits.
  • Electrical sub-distribution and appropriately rated feeder circuits.
  • Electrical infrastructure upgrades, maintenance and replacement projects.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power / SACE Tmax XT2N
ABB order code 1SDX253702R1
Product type Moulded case circuit breaker (MCCB)
Rated current 80 A
Number of poles 4
Electrical configuration Four-pole, suitable for three-phase and neutral switching applications
Short-circuit breaking capacity 36 kA
Protection technology Thermal-magnetic
Trip unit designation TMA
Rated trip unit current 80 A
Protection functions Overload and short-circuit protection
Frame family XT2
Frame current class 160 A
Frame performance designation N
Number of switched poles 4
Device width 120 mm
Operating mechanism Manual switching with automatic protective tripping
Construction Moulded case circuit breaker
Mounting application Compatible electrical distribution assemblies
Application category Low-voltage electrical power distribution
Typical installation ABB Protecta Power panelboards and compatible distribution equipment

Frequently Asked Questions

What is the ABB EPX-XT2N-TM0804 used for?

The ABB EPX-XT2N-TM0804 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.

What is the rated current of the ABB EPX-XT2N-TM0804?

The circuit breaker has a rated current of 80 A. It is designed for appropriately rated electrical circuits requiring 80 A overcurrent protection, with thermal-magnetic protection provided by its TMA trip unit.

What is the breaking capacity of this MCCB?

The ABB EPX-XT2N-TM0804 has a specified 36 kA short-circuit breaking capacity. The suitability of this rating must be assessed against the prospective fault current, operating voltage and applicable installation conditions.

What type of protection does the EPX-XT2N-TM0804 provide?

This MCCB incorporates a thermal-magnetic (TMA) trip unit. The thermal element provides protection against sustained overloads, while the magnetic element provides rapid protection against high short-circuit currents. Its protective characteristics must be coordinated with the electrical circuit and installation requirements.

What is the advantage of the four-pole configuration?

The four-pole configuration allows coordinated switching of four conductors, typically three phases and a neutral, where required by the electrical installation design. This makes the MCCB suitable for three-phase distribution systems requiring four-pole isolation or switching, subject to the applicable earthing and neutral protection requirements.

Trusted by Electrical Professionals Worldwide

ABB Protecta Power protective devices combine established circuit protection technology with practical electrical distribution solutions. The EPX-XT2N-TM0804 offers a compact 80 A, four-pole XT2N MCCB configuration with thermal-magnetic TMA protection and a 36 kA breaking capacity, supporting dependable protection in commercial and industrial low-voltage distribution installations.