1SDX253699R1 ABB EPX-XT2N-TM0404 40A 4P 36kA TMA Moulded Case Circuit Breaker

1SDX253699R1 ABB EPX-XT2N-TM0404 40A 4P 36kA TMA Moulded Case Circuit Breaker

ABB EPX-XT2N-TM0404 (1SDX253699R1) is a 40 A four-pole SACE Tmax XT2N moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and thermal-magnetic adjustable protection for compatible ABB Protecta Power electrical distribution systems.

SKU: 1SDX253699R1Alt SKU: EPX-XT2N-TM0404MPN: 1SDX253699R1
Price
List Price £543.24 ex VAT
Your Price (ex VAT)
£543.24
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £543.24
Trade pricing is personalised to your account

Manufacturer Lead Time

£543.24

Why Choose the ABB EPX-XT2N-TM0404 40A 4-Pole Moulded Case Circuit Breaker?

The ABB EPX-XT2N-TM0404 is a reliable 40 A four-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT2N160 circuit breaker platform, this protective device combines dependable thermal-magnetic protection with a compact design suitable for commercial, industrial and building services installations.

As part of the ABB Protecta Power Devices product group, the EPX-XT2N-TM0404 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its thermal-magnetic adjustable (TMA) trip configuration provides protection against sustained overload conditions and short-circuit faults, helping safeguard electrical cables, connected equipment and distribution infrastructure. The four-pole construction enables coordinated switching of three phase conductors and a neutral conductor where required by the electrical installation design.

With a 40 A rated current, a specified 36 kA short-circuit breaking capacity and a four-pole (4P) configuration, the EPX-XT2N-TM0404 is suitable for appropriately designed three-phase distribution circuits requiring four-pole switching. Its compact 120 mm nominal device width helps optimise available space within distribution boards, making it a practical choice for electrical contractors, panel builders, switchboard manufacturers and facilities engineers.

Key Advantages

  • Dependable 40 A moulded case circuit breaker for commercial and industrial low-voltage electrical distribution.
  • 36 kA short-circuit breaking capacity in the specified ABB Protecta Power configuration.
  • Four-pole (4P) construction supports coordinated switching of three phase conductors and a neutral conductor.
  • Thermal-magnetic adjustable (TMA) protection against overloads and short-circuit faults.
  • Based on the established ABB SACE Tmax XT2N160 circuit breaker platform.
  • 160 A frame platform supports the 40 A protective device configuration.
  • Compact 120 mm nominal width helps conserve distribution board space.
  • Designed for integration into ABB Protecta Power distribution boards.
  • Thermal-magnetic protection supports coordination with appropriately rated cables and connected equipment.
  • Suitable for electrical distribution circuits requiring coordinated four-pole switching.
  • Robust moulded case construction supports dependable circuit protection.
  • Suitable for new installations, electrical distribution upgrades and panel-building projects.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT2N-TM0404 product designation.
  • ABB order code 1SDX253699R1.
  • ABB SACE Tmax XT2N160 circuit breaker platform.
  • 40 A rated current for outgoing circuit protection.
  • 160 A frame rating within the XT2N160 platform.
  • 36 kA specified short-circuit breaking capacity for compatible Protecta Power applications.
  • Four-pole (4P) configuration for coordinated switching of four conductors.
  • Thermal-magnetic adjustable (TMA) trip configuration for overload and short-circuit protection.
  • Thermal overload protection responds to sustained excessive current.
  • Magnetic short-circuit protection provides rapid fault interruption.
  • 120 mm nominal device width for efficient use of distribution board space.
  • Manual operating mechanism for circuit switching and isolation when correctly installed.
  • Designed for installation using compatible ABB Protecta Power mounting and connection accessories.
  • Suitable for commercial, industrial and building services electrical distribution systems.

Reliable Four-Pole Circuit Protection for Low-Voltage Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT2N-TM0404 protect electrical distribution systems by automatically interrupting current when overload or short-circuit conditions occur. The thermal protection element responds to sustained excessive current, while the magnetic protection element operates rapidly during short-circuit faults. This combined protection helps reduce the risk of cable damage, electrical equipment failure and disruption to essential power distribution infrastructure.

The ABB SACE Tmax XT2N160 platform provides dependable low-voltage circuit protection in a compact moulded case design. Its four-pole construction enables coordinated switching of three phase conductors and a neutral conductor, where required by the installation design. This makes the EPX-XT2N-TM0404 suitable for three-phase electrical distribution circuits in which neutral disconnection forms part of the switching arrangement.

The 40 A rated current makes this breaker suitable for appropriately designed outgoing feeders and electrical circuits requiring MCCB protection. Its specified 36 kA breaking capacity provides substantial short-circuit interruption capability for compatible distribution applications. The 120 mm nominal width helps optimise available space within ABB Protecta Power distribution boards.

The TMA trip designation identifies the product as a thermal-magnetic adjustable circuit breaker within the Protecta Power range. Thermal-magnetic protection combines an overload-sensitive thermal element with a magnetic element for rapid short-circuit operation. The precise adjustment ranges, magnetic trip characteristics and neutral protection arrangement should be confirmed against the manufacturer's documentation for ABB order code 1SDX253699R1 before finalising protection settings.

Correct circuit breaker selection should consider the installation operating voltage, prospective short-circuit current, conductor sizing, earthing arrangement, neutral switching requirements and protective device coordination. The applicable breaking capacity and installation accessories should be checked against the complete electrical system design and relevant ABB technical documentation.

Typical Applications

  • ABB Protecta Power low-voltage electrical distribution boards.
  • Three-phase outgoing circuits requiring four-pole switching.
  • Commercial building electrical distribution and sub-distribution installations.
  • Industrial electrical distribution panels and manufacturing facilities.
  • Three-phase equipment supplies where neutral switching is required.
  • Electrical distribution for workshops, warehouses and logistics facilities.
  • Building services infrastructure and mechanical plant electrical supplies.
  • Distribution board upgrades requiring compact four-pole MCCB protection.
  • Electrical switchboard manufacturing and power distribution panel assembly.

Technical Specifications

Product group Protecta Power Devices
Series SACE Tmax XT
Circuit breaker platform XT2N160
ABB order code 1SDX253699R1
Product type Moulded case circuit breaker (MCCB)
Rated current 40 A
Frame rating 160 A
Breaking capacity 36 kA (specified Protecta Power application)
Number of poles 4
Pole configuration Four-pole (4P)
Trip configuration Thermal-magnetic adjustable (TMA)
Trip technology Thermal-magnetic
Thermal protection Overload protection
Magnetic protection Short-circuit protection
Protection functions Overload and short-circuit protection
Neutral switching Four-pole construction; neutral protection characteristics depend on the fitted release
Applicable circuit breaker standard IEC 60947-2
Nominal device width 120 mm
Mounting type Compatible ABB Protecta Power distribution assembly
Installation Fixed distribution board installation using compatible mounting and connection accessories
Application Three-phase low-voltage electrical power distribution with four-pole switching

Frequently Asked Questions

What is the ABB EPX-XT2N-TM0404 used for?

The ABB EPX-XT2N-TM0404 is a 40 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems. Its four-pole construction supports installations requiring coordinated switching of three phase conductors and a neutral conductor.

What is the rated current and breaking capacity of this circuit breaker?

The EPX-XT2N-TM0404 has a 40 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB XT2N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be assessed against the installation operating voltage and prospective fault current.

What does TMA mean on the ABB EPX-XT2N-TM0404?

TMA stands for Thermal-Magnetic Adjustable. This protection technology combines thermal overload detection with magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid operation during short-circuit faults. Exact adjustment ranges and magnetic trip characteristics should be confirmed against the specific ABB XT2N160 release fitted to the breaker.

What is the advantage of the four-pole configuration?

The four-pole (4P) configuration enables coordinated switching of three phase conductors and a neutral conductor. This is useful in electrical distribution systems where neutral disconnection is required by the installation design. The presence of a fourth pole does not automatically confirm the neutral protection characteristics, which must be checked against the specific circuit breaker configuration.

Where is the ABB EPX-XT2N-TM0404 typically installed?

The breaker is intended for installation within compatible ABB Protecta Power distribution boards, where it provides outgoing circuit protection. The ABB XT2N four-pole platform has a nominal width of 120 mm, supporting compact distribution board layouts. Compatible mounting and connection accessories should be selected for the specific installation.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely specified by electrical engineers, contractors and panel builders for dependable low-voltage power distribution. The EPX-XT2N-TM0404 combines 40 A circuit protection, four-pole switching, 36 kA specified short-circuit breaking capacity and thermal-magnetic protection to support reliable commercial and industrial ABB Protecta Power electrical distribution installations.