Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT2N-TM0404 (1SDX253699R1) is a 40 A four-pole SACE Tmax XT2N moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and thermal-magnetic adjustable protection for compatible ABB Protecta Power electrical distribution systems.
£543.24
The ABB EPX-XT2N-TM0404 is a reliable 40 A four-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT2N160 circuit breaker platform, this protective device combines dependable thermal-magnetic protection with a compact design suitable for commercial, industrial and building services installations.
As part of the ABB Protecta Power Devices product group, the EPX-XT2N-TM0404 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its thermal-magnetic adjustable (TMA) trip configuration provides protection against sustained overload conditions and short-circuit faults, helping safeguard electrical cables, connected equipment and distribution infrastructure. The four-pole construction enables coordinated switching of three phase conductors and a neutral conductor where required by the electrical installation design.
With a 40 A rated current, a specified 36 kA short-circuit breaking capacity and a four-pole (4P) configuration, the EPX-XT2N-TM0404 is suitable for appropriately designed three-phase distribution circuits requiring four-pole switching. Its compact 120 mm nominal device width helps optimise available space within distribution boards, making it a practical choice for electrical contractors, panel builders, switchboard manufacturers and facilities engineers.
Moulded case circuit breakers such as the ABB EPX-XT2N-TM0404 protect electrical distribution systems by automatically interrupting current when overload or short-circuit conditions occur. The thermal protection element responds to sustained excessive current, while the magnetic protection element operates rapidly during short-circuit faults. This combined protection helps reduce the risk of cable damage, electrical equipment failure and disruption to essential power distribution infrastructure.
The ABB SACE Tmax XT2N160 platform provides dependable low-voltage circuit protection in a compact moulded case design. Its four-pole construction enables coordinated switching of three phase conductors and a neutral conductor, where required by the installation design. This makes the EPX-XT2N-TM0404 suitable for three-phase electrical distribution circuits in which neutral disconnection forms part of the switching arrangement.
The 40 A rated current makes this breaker suitable for appropriately designed outgoing feeders and electrical circuits requiring MCCB protection. Its specified 36 kA breaking capacity provides substantial short-circuit interruption capability for compatible distribution applications. The 120 mm nominal width helps optimise available space within ABB Protecta Power distribution boards.
The TMA trip designation identifies the product as a thermal-magnetic adjustable circuit breaker within the Protecta Power range. Thermal-magnetic protection combines an overload-sensitive thermal element with a magnetic element for rapid short-circuit operation. The precise adjustment ranges, magnetic trip characteristics and neutral protection arrangement should be confirmed against the manufacturer's documentation for ABB order code 1SDX253699R1 before finalising protection settings.
Correct circuit breaker selection should consider the installation operating voltage, prospective short-circuit current, conductor sizing, earthing arrangement, neutral switching requirements and protective device coordination. The applicable breaking capacity and installation accessories should be checked against the complete electrical system design and relevant ABB technical documentation.
| Product group | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT |
| Circuit breaker platform | XT2N160 |
| ABB order code | 1SDX253699R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 40 A |
| Frame rating | 160 A |
| Breaking capacity | 36 kA (specified Protecta Power application) |
| Number of poles | 4 |
| Pole configuration | Four-pole (4P) |
| Trip configuration | Thermal-magnetic adjustable (TMA) |
| Trip technology | Thermal-magnetic |
| Thermal protection | Overload protection |
| Magnetic protection | Short-circuit protection |
| Protection functions | Overload and short-circuit protection |
| Neutral switching | Four-pole construction; neutral protection characteristics depend on the fitted release |
| Applicable circuit breaker standard | IEC 60947-2 |
| Nominal device width | 120 mm |
| Mounting type | Compatible ABB Protecta Power distribution assembly |
| Installation | Fixed distribution board installation using compatible mounting and connection accessories |
| Application | Three-phase low-voltage electrical power distribution with four-pole switching |
The ABB EPX-XT2N-TM0404 is a 40 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems. Its four-pole construction supports installations requiring coordinated switching of three phase conductors and a neutral conductor.
The EPX-XT2N-TM0404 has a 40 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB XT2N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be assessed against the installation operating voltage and prospective fault current.
TMA stands for Thermal-Magnetic Adjustable. This protection technology combines thermal overload detection with magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element provides rapid operation during short-circuit faults. Exact adjustment ranges and magnetic trip characteristics should be confirmed against the specific ABB XT2N160 release fitted to the breaker.
The four-pole (4P) configuration enables coordinated switching of three phase conductors and a neutral conductor. This is useful in electrical distribution systems where neutral disconnection is required by the installation design. The presence of a fourth pole does not automatically confirm the neutral protection characteristics, which must be checked against the specific circuit breaker configuration.
The breaker is intended for installation within compatible ABB Protecta Power distribution boards, where it provides outgoing circuit protection. The ABB XT2N four-pole platform has a nominal width of 120 mm, supporting compact distribution board layouts. Compatible mounting and connection accessories should be selected for the specific installation.
ABB SACE Tmax XT circuit breakers are widely specified by electrical engineers, contractors and panel builders for dependable low-voltage power distribution. The EPX-XT2N-TM0404 combines 40 A circuit protection, four-pole switching, 36 kA specified short-circuit breaking capacity and thermal-magnetic protection to support reliable commercial and industrial ABB Protecta Power electrical distribution installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.