1SDX253698R1 ABB EPX-XT2N-TM0324 32A 4P 36kA TMA Moulded Case Circuit Breaker

1SDX253698R1 ABB EPX-XT2N-TM0324 32A 4P 36kA TMA Moulded Case Circuit Breaker

ABB EPX-XT2N-TM0324 (1SDX253698R1) is a 32 A four-pole SACE Tmax XT2N moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and thermal-magnetic protection for compatible ABB Protecta Power electrical distribution systems.

SKU: 1SDX253698R1Alt SKU: EPX-XT2N-TM0324MPN: 1SDX253698R1
Price
List Price £543.24 ex VAT
Your Price (ex VAT)
£543.24
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £543.24
Trade pricing is personalised to your account

Manufacturer Lead Time

£543.24

Why Choose the ABB EPX-XT2N-TM0324 32A 4-Pole Moulded Case Circuit Breaker?

The ABB EPX-XT2N-TM0324 is a dependable 32 A four-pole moulded case circuit breaker (MCCB) designed to provide overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT2N160 circuit breaker platform, this device combines reliable thermal-magnetic protection with a compact construction suitable for commercial, industrial and building services installations.

As part of the ABB Protecta Power Devices product group, the EPX-XT2N-TM0324 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its specified thermal-magnetic adjustable (TMA) configuration provides protection against sustained overload conditions and short-circuit faults, helping safeguard electrical cables, connected equipment and distribution infrastructure. The four-pole construction enables coordinated switching of three phase conductors and a neutral conductor where required by the installation design.

With a 32 A rated current, a specified 36 kA short-circuit breaking capacity and a four-pole (4P) configuration, the EPX-XT2N-TM0324 is suitable for appropriately designed three-phase distribution circuits requiring four-pole switching. Its compact 120 mm nominal device width helps optimise available distribution board space, making it a practical choice for electrical contractors, panel builders, switchboard manufacturers and facilities engineers.

Key Advantages

  • Reliable 32 A moulded case circuit breaker for commercial and industrial low-voltage electrical distribution.
  • 36 kA short-circuit breaking capacity in the specified ABB Protecta Power configuration.
  • Four-pole (4P) construction supports coordinated switching of three phase conductors and a neutral conductor.
  • Thermal-magnetic protection against sustained overloads and short-circuit faults.
  • Specified TMA configuration within the ABB Protecta Power product range.
  • Based on the established ABB SACE Tmax XT2N160 circuit breaker platform.
  • 160 A frame platform supports the compact 32 A protective device configuration.
  • Compact 120 mm nominal width helps conserve distribution board space.
  • Designed for integration into ABB Protecta Power distribution boards.
  • Suitable for distribution circuits requiring coordinated four-pole switching.
  • Robust moulded case construction supports dependable electrical protection.
  • Suitable for new installations, electrical distribution upgrades and panel-building projects.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT2N-TM0324 product designation.
  • ABB order code 1SDX253698R1.
  • ABB SACE Tmax XT2N160 circuit breaker platform.
  • 32 A rated current for outgoing circuit protection.
  • 160 A frame rating within the XT2N160 platform.
  • 36 kA specified short-circuit breaking capacity for compatible Protecta Power applications.
  • Four-pole (4P) configuration for coordinated switching of four conductors.
  • Thermal-magnetic trip technology for overload and short-circuit protection.
  • TMA designation in the supplied ABB Protecta Power product specification.
  • Thermal overload protection responds to sustained excessive current.
  • Magnetic short-circuit protection provides rapid fault interruption.
  • 120 mm nominal device width for efficient use of distribution board space.
  • Manual operating mechanism for circuit switching and isolation when correctly installed.
  • Designed for installation using compatible ABB Protecta Power mounting and connection accessories.
  • Suitable for commercial, industrial and building services electrical distribution systems.

Reliable Four-Pole Circuit Protection for Low-Voltage Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT2N-TM0324 protect electrical distribution systems by automatically interrupting current when overload or short-circuit conditions occur. Thermal protection responds to sustained excessive current, while magnetic protection provides rapid operation during short-circuit faults. These complementary protection functions help reduce the risk of cable damage, electrical equipment failure and disruption to power distribution infrastructure.

The ABB SACE Tmax XT2N160 platform provides dependable low-voltage circuit protection in a compact moulded case design. Its four-pole configuration allows coordinated switching of three phase conductors and a neutral conductor where required by the electrical installation. This makes the EPX-XT2N-TM0324 suitable for three-phase distribution circuits in which neutral disconnection is part of the protective and switching arrangement.

The 32 A rated current makes this circuit breaker suitable for appropriately designed lower-current outgoing feeders requiring MCCB protection. Its specified 36 kA breaking capacity provides substantial short-circuit interruption capability for compatible distribution applications. The 120 mm nominal width helps conserve space within ABB Protecta Power distribution boards.

The product is identified as TMA in the supplied Protecta Power specification. However, ABB's XT2N160 selection information identifies lower-current thermal-magnetic releases, including the 32 A configuration, as TMD in some catalogues. TMD typically denotes an adjustable thermal setting with a fixed magnetic setting. The precise release type, available adjustment ranges and neutral protection arrangement should therefore be confirmed against the manufacturer's documentation for ABB order code 1SDX253698R1 before commissioning.

Correct circuit breaker selection should consider the installation operating voltage, prospective short-circuit current, conductor sizing, earthing arrangement, neutral switching requirements and protective device coordination. The applicable breaking capacity and installation accessories should be checked against the complete electrical system design and relevant ABB technical documentation.

Typical Applications

  • ABB Protecta Power low-voltage electrical distribution boards.
  • Three-phase outgoing circuits requiring four-pole switching.
  • Commercial building electrical distribution and sub-distribution installations.
  • Industrial electrical distribution panels and manufacturing facilities.
  • Three-phase equipment supplies where neutral switching is required.
  • Electrical distribution for workshops, warehouses and logistics facilities.
  • Building services infrastructure and mechanical plant electrical supplies.
  • Distribution board upgrades requiring compact four-pole MCCB protection.
  • Electrical switchboard manufacturing and power distribution panel assembly.

Technical Specifications

Product group Protecta Power Devices
Series SACE Tmax XT
Circuit breaker platform XT2N160
ABB order code 1SDX253698R1
Product type Moulded case circuit breaker (MCCB)
Rated current 32 A
Frame rating 160 A
Breaking capacity 36 kA (specified Protecta Power application)
Number of poles 4
Pole configuration Four-pole (4P)
Specified trip configuration Thermal-magnetic adjustable (TMA)
Trip technology Thermal-magnetic
Thermal protection Overload protection
Magnetic protection Short-circuit protection
Protection functions Overload and short-circuit protection
Neutral switching Four-pole construction; neutral protection characteristics depend on the fitted release
Applicable circuit breaker standard IEC 60947-2
Nominal device width 120 mm
Mounting type Compatible ABB Protecta Power distribution assembly
Installation Fixed distribution board installation using compatible mounting and connection accessories
Application Three-phase low-voltage electrical power distribution with four-pole switching

Frequently Asked Questions

What is the ABB EPX-XT2N-TM0324 used for?

The ABB EPX-XT2N-TM0324 is a 32 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems. Its four-pole construction supports installations requiring coordinated switching of three phase conductors and a neutral conductor.

What is the rated current and breaking capacity of this circuit breaker?

The EPX-XT2N-TM0324 has a 32 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB XT2N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be assessed against the installation operating voltage and prospective fault current.

What does TMA mean on the ABB EPX-XT2N-TM0324?

TMA stands for Thermal-Magnetic Adjustable. Thermal-magnetic protection combines overload detection with rapid short-circuit protection. The supplied product specification identifies this model as TMA, although ABB's XT2N160 selection information identifies some 32 A thermal-magnetic configurations as TMD, which typically uses an adjustable thermal setting and fixed magnetic setting. The exact fitted release characteristics should be confirmed against ABB order code 1SDX253698R1.

What is the advantage of the four-pole configuration?

The four-pole (4P) configuration enables coordinated switching of three phase conductors and a neutral conductor. This is useful in electrical distribution systems where neutral disconnection is required by the installation design. The presence of a fourth pole does not automatically confirm the neutral protection characteristics, which must be checked against the specific circuit breaker configuration.

Where is the ABB EPX-XT2N-TM0324 typically installed?

The breaker is intended for installation within compatible ABB Protecta Power distribution boards, where it provides outgoing circuit protection. The ABB XT2N four-pole platform has a nominal width of 120 mm, supporting compact distribution board layouts. Compatible mounting and connection accessories should be selected for the specific installation.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely specified by electrical engineers, contractors and panel builders for dependable low-voltage power distribution. The EPX-XT2N-TM0324 combines 32 A circuit protection, four-pole switching, 36 kA specified short-circuit breaking capacity and thermal-magnetic protection to support reliable commercial and industrial ABB Protecta Power electrical distribution installations.