Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT2N-TM0324 (1SDX253698R1) is a 32 A four-pole SACE Tmax XT2N moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and thermal-magnetic protection for compatible ABB Protecta Power electrical distribution systems.
£543.24
The ABB EPX-XT2N-TM0324 is a dependable 32 A four-pole moulded case circuit breaker (MCCB) designed to provide overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT2N160 circuit breaker platform, this device combines reliable thermal-magnetic protection with a compact construction suitable for commercial, industrial and building services installations.
As part of the ABB Protecta Power Devices product group, the EPX-XT2N-TM0324 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its specified thermal-magnetic adjustable (TMA) configuration provides protection against sustained overload conditions and short-circuit faults, helping safeguard electrical cables, connected equipment and distribution infrastructure. The four-pole construction enables coordinated switching of three phase conductors and a neutral conductor where required by the installation design.
With a 32 A rated current, a specified 36 kA short-circuit breaking capacity and a four-pole (4P) configuration, the EPX-XT2N-TM0324 is suitable for appropriately designed three-phase distribution circuits requiring four-pole switching. Its compact 120 mm nominal device width helps optimise available distribution board space, making it a practical choice for electrical contractors, panel builders, switchboard manufacturers and facilities engineers.
Moulded case circuit breakers such as the ABB EPX-XT2N-TM0324 protect electrical distribution systems by automatically interrupting current when overload or short-circuit conditions occur. Thermal protection responds to sustained excessive current, while magnetic protection provides rapid operation during short-circuit faults. These complementary protection functions help reduce the risk of cable damage, electrical equipment failure and disruption to power distribution infrastructure.
The ABB SACE Tmax XT2N160 platform provides dependable low-voltage circuit protection in a compact moulded case design. Its four-pole configuration allows coordinated switching of three phase conductors and a neutral conductor where required by the electrical installation. This makes the EPX-XT2N-TM0324 suitable for three-phase distribution circuits in which neutral disconnection is part of the protective and switching arrangement.
The 32 A rated current makes this circuit breaker suitable for appropriately designed lower-current outgoing feeders requiring MCCB protection. Its specified 36 kA breaking capacity provides substantial short-circuit interruption capability for compatible distribution applications. The 120 mm nominal width helps conserve space within ABB Protecta Power distribution boards.
The product is identified as TMA in the supplied Protecta Power specification. However, ABB's XT2N160 selection information identifies lower-current thermal-magnetic releases, including the 32 A configuration, as TMD in some catalogues. TMD typically denotes an adjustable thermal setting with a fixed magnetic setting. The precise release type, available adjustment ranges and neutral protection arrangement should therefore be confirmed against the manufacturer's documentation for ABB order code 1SDX253698R1 before commissioning.
Correct circuit breaker selection should consider the installation operating voltage, prospective short-circuit current, conductor sizing, earthing arrangement, neutral switching requirements and protective device coordination. The applicable breaking capacity and installation accessories should be checked against the complete electrical system design and relevant ABB technical documentation.
| Product group | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT |
| Circuit breaker platform | XT2N160 |
| ABB order code | 1SDX253698R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 32 A |
| Frame rating | 160 A |
| Breaking capacity | 36 kA (specified Protecta Power application) |
| Number of poles | 4 |
| Pole configuration | Four-pole (4P) |
| Specified trip configuration | Thermal-magnetic adjustable (TMA) |
| Trip technology | Thermal-magnetic |
| Thermal protection | Overload protection |
| Magnetic protection | Short-circuit protection |
| Protection functions | Overload and short-circuit protection |
| Neutral switching | Four-pole construction; neutral protection characteristics depend on the fitted release |
| Applicable circuit breaker standard | IEC 60947-2 |
| Nominal device width | 120 mm |
| Mounting type | Compatible ABB Protecta Power distribution assembly |
| Installation | Fixed distribution board installation using compatible mounting and connection accessories |
| Application | Three-phase low-voltage electrical power distribution with four-pole switching |
The ABB EPX-XT2N-TM0324 is a 32 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems. Its four-pole construction supports installations requiring coordinated switching of three phase conductors and a neutral conductor.
The EPX-XT2N-TM0324 has a 32 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB XT2N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be assessed against the installation operating voltage and prospective fault current.
TMA stands for Thermal-Magnetic Adjustable. Thermal-magnetic protection combines overload detection with rapid short-circuit protection. The supplied product specification identifies this model as TMA, although ABB's XT2N160 selection information identifies some 32 A thermal-magnetic configurations as TMD, which typically uses an adjustable thermal setting and fixed magnetic setting. The exact fitted release characteristics should be confirmed against ABB order code 1SDX253698R1.
The four-pole (4P) configuration enables coordinated switching of three phase conductors and a neutral conductor. This is useful in electrical distribution systems where neutral disconnection is required by the installation design. The presence of a fourth pole does not automatically confirm the neutral protection characteristics, which must be checked against the specific circuit breaker configuration.
The breaker is intended for installation within compatible ABB Protecta Power distribution boards, where it provides outgoing circuit protection. The ABB XT2N four-pole platform has a nominal width of 120 mm, supporting compact distribution board layouts. Compatible mounting and connection accessories should be selected for the specific installation.
ABB SACE Tmax XT circuit breakers are widely specified by electrical engineers, contractors and panel builders for dependable low-voltage power distribution. The EPX-XT2N-TM0324 combines 32 A circuit protection, four-pole switching, 36 kA specified short-circuit breaking capacity and thermal-magnetic protection to support reliable commercial and industrial ABB Protecta Power electrical distribution installations.
We use cookies