1SDX253697R1 ABB EPX-XT2N-TM0254 25A 4-Pole 36kA TMA MCCB

1SDX253697R1 ABB EPX-XT2N-TM0254 25A 4-Pole 36kA TMA MCCB

ABB EPX-XT2N-TM0254 is a 25 A four-pole SACE Tmax XT2N moulded case circuit breaker with a specified 36 kA breaking capacity and thermal-magnetic adjustable protection for compatible ABB Protecta Power distribution assemblies.

SKU: 1SDX253697R1Alt SKU: EPX-XT2N-TM0254MPN: 1SDX253697R1
Price
List Price £543.24 ex VAT
Your Price (ex VAT)
£543.24
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £543.24
Trade pricing is personalised to your account

Manufacturer Lead Time

£543.24

Why Choose the ABB EPX-XT2N-TM0254 25A 4-Pole MCCB?

The ABB EPX-XT2N-TM0254 is a 25 A four-pole moulded case circuit breaker (MCCB) featuring a 36 kA specified breaking capacity and thermal-magnetic adjustable (TMA) protection. Incorporating the ABB SACE Tmax XT2N circuit breaker designation, this device belongs to the ABB Protecta Power Devices range for low-voltage electrical distribution applications.

Designed to protect electrical circuits against overload and short-circuit conditions, the EPX-XT2N-TM0254 combines thermal overload protection with magnetic short-circuit protection. Its four-pole configuration supports suitable three-phase electrical distribution arrangements requiring four-pole switching.

With a 25 A rated current, 36 kA breaking capacity and TMA trip protection, this MCCB provides a circuit protection option for compatible ABB Protecta Power distribution assemblies. The exact manufacturer configuration is identified by ABB order code 1SDX253697R1.

Key Advantages

  • 25 A rated current for appropriately designed low-voltage distribution circuits.
  • Four-pole (4P) configuration for suitable three-phase and neutral switching arrangements.
  • 36 kA specified breaking capacity for installations with appropriately assessed short-circuit fault levels.
  • Thermal-magnetic adjustable (TMA) protection against overload and short-circuit conditions.
  • Incorporates the ABB SACE Tmax XT2N circuit breaker designation.
  • Combines a 25 A current rating with substantial specified fault-interruption capability.
  • Designed for compatible ABB Protecta Power distribution assemblies.
  • Suitable for commercial and industrial low-voltage electrical distribution applications.

Key Features

  • ABB Protecta Power Devices product range.
  • SACE Tmax XT2N moulded case circuit breaker designation.
  • 25 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA specified breaking capacity.
  • TMA thermal-magnetic adjustable trip protection.
  • Thermal overload protection against sustained overcurrent conditions.
  • Magnetic short-circuit protection against fault currents.
  • Manual circuit switching functionality.
  • Intended for compatible ABB Protecta Power low-voltage distribution equipment.

Reliable 25A Thermal-Magnetic Protection for Four-Pole Distribution Circuits

The ABB EPX-XT2N-TM0254 combines a 25 A rated current with a 36 kA specified breaking capacity, providing an MCCB option for appropriately designed low-voltage distribution circuits. Its thermal-magnetic adjustable trip arrangement responds to sustained overload conditions and short-circuit faults.

The thermal protection element responds to excessive current sustained over time, while the magnetic protection element responds to short-circuit conditions. Together, these functions help protect electrical conductors and connected equipment when the circuit breaker is correctly selected, installed and coordinated with other protective devices.

The four-pole XT2N configuration supports appropriate three-phase distribution arrangements requiring four-pole switching. Electrical designers should verify the operating voltage, prospective short-circuit current, conductor sizing, protection settings and compatibility with the selected distribution assembly before installation.

Typical Applications

  • Compatible ABB Protecta Power low-voltage distribution assemblies.
  • 25 A four-pole outgoing circuit protection.
  • Commercial three-phase electrical distribution boards.
  • Industrial electrical panelboard installations.
  • Three-phase equipment feeder protection.
  • Building services electrical distribution systems.
  • Circuits requiring thermal-magnetic MCCB protection.
  • Installations requiring an appropriately rated 36 kA circuit breaker.
  • Electrical distribution upgrades and refurbishment projects.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
ABB order code 1SDX253697R1
Product type Moulded case circuit breaker (MCCB)
Frame designation XT2
Performance designation XT2N
Rated current 25 A
Number of poles 4
Pole configuration Four-pole (4P)
Specified breaking capacity 36 kA
Trip unit Thermal-magnetic adjustable (TMA)
Overload protection Thermal
Short-circuit protection Magnetic
Electrical application Low-voltage power distribution
Product group Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT2N-TM0254 used for?

The ABB EPX-XT2N-TM0254 is a 25 A four-pole MCCB intended to provide overload and short-circuit protection in compatible low-voltage distribution systems.

What is the rated current of the EPX-XT2N-TM0254?

The circuit breaker has a rated current of 25 A.

How many poles does the EPX-XT2N-TM0254 have?

The device has a four-pole (4P) configuration suitable for appropriately designed three-phase and neutral switching arrangements.

What is the breaking capacity of the EPX-XT2N-TM0254?

The device is specified with a 36 kA breaking capacity. The applicable operating voltage and prospective short-circuit current must be checked before installation.

What does TMA mean on the EPX-XT2N-TM0254?

TMA means thermal-magnetic adjustable, identifying a trip protection arrangement combining thermal overload protection with magnetic short-circuit protection.

Which ABB circuit breaker series does the EPX-XT2N-TM0254 use?

The product incorporates the ABB SACE Tmax XT2N circuit breaker designation.

What is the difference between the EPX-XT2N-TM0254 and EPX-XT2N-TM0204?

The EPX-XT2N-TM0254 is rated at 25 A, while the EPX-XT2N-TM0204 is rated at 20 A. Both are specified as four-pole XT2N MCCBs with 36 kA breaking capacity and TMA protection.

Does the EPX-XT2N-TM0254 use electronic LSI protection?

No. This configuration is specified with TMA thermal-magnetic adjustable protection, rather than electronic LSI protection.

What is the ABB order code for the EPX-XT2N-TM0254?

The ABB manufacturer order code is 1SDX253697R1.

Trusted by Electrical Contractors and Power Distribution Professionals

The ABB EPX-XT2N-TM0254 25 A Four-Pole MCCB is designed for electrical contractors, panel builders and distribution system designers specifying a 36 kA XT2N circuit breaker with thermal-magnetic adjustable protection for compatible ABB Protecta Power installations.