1SDX253690R1 ABB EPX-XT1N-TM0504 50A 4-Pole 36kA TMA MCCB

1SDX253690R1 ABB EPX-XT1N-TM0504 50A 4-Pole 36kA TMA MCCB

ABB EPX-XT1N-TM0504 is a 50 A four-pole moulded case circuit breaker from the Protecta Power range, featuring a 36 kA breaking capacity and thermal-magnetic TMA protection for low-voltage electrical distribution systems.

SKU: 1SDX253690R1Alt SKU: EPX-XT1N-TM0504MPN: 1SDX253690R1
Price
List Price £468.53 ex VAT
Your Price (ex VAT)
£468.53
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £468.53
Trade pricing is personalised to your account

Manufacturer Lead Time

£468.53

Why Choose the ABB EPX-XT1N-TM0504 50A 4-Pole MCCB?

The ABB EPX-XT1N-TM0504 is a reliable 50 A four-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the proven ABB Tmax XT1N circuit breaker platform, it is engineered for dependable circuit protection in commercial, industrial and electrical distribution applications.

This circuit breaker features a thermal-magnetic TMA trip unit, combining thermal overload protection with magnetic short-circuit protection to help safeguard electrical installations, connected equipment and distribution circuits. Its four-pole configuration supports three-phase distribution systems with a neutral conductor, making it suitable for electrical distribution boards and power distribution assemblies.

With a rated current of 50 A and a 36 kA breaking capacity, the EPX-XT1N-TM0504 provides robust protection for electrical installations requiring reliable fault interruption. Its compact XT1N frame is designed for integration into low-voltage distribution equipment, including ABB Protecta Power assemblies and compatible electrical control panels.

Key Advantages

  • Reliable 50 A moulded case circuit breaker for low-voltage electrical distribution.
  • Four-pole configuration suitable for three-phase systems with a neutral conductor.
  • 36 kA breaking capacity for effective short-circuit protection.
  • Integrated thermal-magnetic TMA trip unit provides overload and short-circuit protection.
  • Compact ABB Tmax XT1N frame supports efficient use of distribution board space.
  • Designed for integration into ABB Protecta Power distribution systems.
  • Mechanical switching mechanism provides manual circuit isolation and resetting following a trip.
  • Suitable for commercial, industrial and infrastructure electrical installations.

Key Features

  • ABB Protecta Power Devices range.
  • ABB Tmax XT1N moulded case circuit breaker platform.
  • 50 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA rated breaking capacity.
  • TMA thermal-magnetic protection for overload and short-circuit faults.
  • Compact moulded case construction for electrical distribution assemblies.
  • Manual operating handle with circuit switching and reset functionality.
  • Suitable for three-phase low-voltage distribution applications.
  • Designed for use with compatible ABB Tmax XT accessories and installation equipment.

Reliable Circuit Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT1N-TM0504 protect electrical distribution circuits by interrupting current when overloads or short-circuit faults occur. The integrated thermal-magnetic trip mechanism combines a thermal element for overload protection with a magnetic element that responds rapidly to high fault currents, helping minimise the risk of damage to cables, connected equipment and electrical infrastructure.

The ABB Tmax XT circuit breaker family is designed for dependable performance in low-voltage electrical installations. Its compact construction and compatibility with appropriate ABB distribution accessories support straightforward integration into commercial and industrial power distribution systems. The EPX-XT1N-TM0504 is particularly suitable for applications requiring 50 A four-pole circuit protection with a 36 kA fault-breaking rating, subject to verification of the installation voltage, prospective fault current and coordination requirements.

Typical Applications

  • Commercial and industrial electrical distribution boards.
  • ABB Protecta Power distribution assemblies.
  • Three-phase electrical distribution systems with neutral conductors.
  • Low-voltage switchboards and power distribution panels.
  • Industrial machinery supply circuits and control panel incomers.
  • Building services and electrical infrastructure installations.
  • Electrical feeder and sub-distribution circuit protection.
  • Manufacturing facilities, warehouses and commercial premises.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker series Tmax XT
Frame designation XT1N
ABB order code 1SDX253690R1
Product type Moulded case circuit breaker (MCCB)
Rated current 50 A
Number of poles 4
Breaking capacity 36 kA
Trip unit type TMA thermal-magnetic
Protection functions Overload and short-circuit protection
Frame family XT1N160
Frame size rating 160 A
Four-pole frame width 110 mm
Operating mechanism Manual toggle operation
Application Low-voltage power distribution
Installation Electrical distribution boards and compatible panel assemblies
Applicable circuit breaker standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB EPX-XT1N-TM0504 used for?

The ABB EPX-XT1N-TM0504 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.

What is the rated current of the EPX-XT1N-TM0504?

The circuit breaker has a 50 A rated current, making it suitable for appropriately designed electrical distribution circuits requiring 50 A protection.

What is the breaking capacity of this MCCB?

The EPX-XT1N-TM0504 has a specified 36 kA breaking capacity. The applicable breaking capacity must be checked against the installation voltage and prospective short-circuit current.

What type of protection does the TMA trip unit provide?

The TMA thermal-magnetic trip unit provides thermal overload protection and magnetic short-circuit protection, automatically disconnecting the circuit when the relevant trip conditions occur.

Where is the ABB EPX-XT1N-TM0504 typically installed?

This MCCB is typically installed in low-voltage electrical distribution boards, switchboards and compatible ABB Protecta Power assemblies, where four-pole circuit protection is required.

Trusted by Electrical Engineers and Industrial Installers Worldwide

ABB Tmax XT moulded case circuit breakers are designed to deliver dependable overload and short-circuit protection in modern electrical distribution systems. The ABB EPX-XT1N-TM0504 combines a 50 A rating, four-pole construction and thermal-magnetic protection in a compact circuit breaker suitable for commercial and industrial power distribution applications.