1SDX253689R1 ABB EPX-XT1N-TM0404 40A 4P 36kA MCCB TMA

1SDX253689R1 ABB EPX-XT1N-TM0404 40A 4P 36kA MCCB TMA

ABB EPX-XT1N-TM0404 is a 40 A four-pole SACE Tmax XT1N moulded case circuit breaker with 36 kA breaking capacity and TMA thermal-magnetic protection for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX253689R1Alt SKU: EPX-XT1N-TM0404MPN: 1SDX253689R1
Price
List Price £468.53 ex VAT
Your Price (ex VAT)
£468.53
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £468.53
Trade pricing is personalised to your account

Manufacturer Lead Time

£468.53

Why Choose the ABB EPX-XT1N-TM0404 Protecta Power Circuit Breaker?

The ABB EPX-XT1N-TM0404 is a compact and reliable 40 A four-pole moulded case circuit breaker (MCCB) designed to protect low-voltage electrical distribution circuits against overloads and short circuits. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the ABB SACE Tmax XT1N platform with a TMA thermal-magnetic protection arrangement, providing dependable circuit protection for commercial and industrial electrical installations.

With a 36 kA short-circuit breaking capacity, the EPX-XT1N-TM0404 is designed to interrupt high fault currents while helping safeguard electrical conductors, distribution equipment and connected loads. Its thermal-magnetic protection combines overload protection with rapid short-circuit fault interruption, supporting safe and reliable operation in appropriately designed low-voltage systems.

Featuring a 40 A rated current, four-pole configuration and compact 110 mm nominal width, this MCCB is suitable for compatible three-phase distribution systems requiring four-pole switching. Its established ABB Tmax XT1N construction makes it a practical solution for electrical contractors, panel builders and maintenance engineers working with ABB Protecta Power distribution assemblies.

Key Advantages

  • 40 A rated current for protection of appropriately designed low-voltage electrical circuits.
  • Four-pole (4P) configuration supports switching of three phase conductors and a neutral conductor where required.
  • 36 kA short-circuit breaking capacity provides protection against substantial prospective fault currents.
  • TMA thermal-magnetic protection combines overload and short-circuit protection in one device.
  • ABB SACE Tmax XT1N platform provides dependable switching and circuit protection.
  • Compact 110 mm nominal width helps optimise space within electrical distribution boards.
  • Thermal-magnetic protection operates without requiring an external auxiliary power supply.
  • Designed for integration into compatible ABB Protecta Power switchboards.

Key Features

  • ABB Protecta Power Devices product family.
  • EPX-XT1N-TM0404 model designation.
  • ABB SACE Tmax XT1N moulded case circuit breaker platform.
  • 40 A rated current.
  • XT1N160 frame with a maximum frame rating of 160 A.
  • Four-pole (4P) circuit breaker construction.
  • 36 kA short-circuit breaking capacity.
  • TMA thermal-magnetic trip arrangement.
  • Thermal overload protection against sustained excessive current.
  • Magnetic short-circuit protection for rapid fault interruption.
  • Four-pole switching capability for compatible three-phase and neutral distribution systems.
  • Manual operating mechanism for circuit switching and resetting.
  • 110 mm nominal width for the four-pole XT1 configuration.
  • Suitable for low-voltage AC electrical distribution applications.
  • Compatible with appropriately selected ABB Tmax XT1 mounting and connection accessories.

Reliable Thermal-Magnetic Protection for Four-Pole Distribution

The ABB EPX-XT1N-TM0404 incorporates TMA thermal-magnetic protection to safeguard electrical installations against sustained overloads and short-circuit faults. The thermal protection element responds to excessive current over time, helping prevent overheating of electrical conductors and connected equipment. The magnetic protection element responds rapidly to high fault currents, enabling prompt circuit disconnection.

The four-pole construction supports applications where three phase conductors and a neutral conductor must be switched together. This arrangement is particularly useful in compatible three-phase distribution systems requiring neutral switching. The neutral pole's protection characteristics and suitability must be verified for the selected circuit breaker configuration and installation requirements.

The ABB SACE Tmax XT1N160 platform offers a compact moulded case design for commercial and industrial power distribution. Its nominal four-pole width of 110 mm helps optimise switchboard space while providing the switching and protective functions required for low-voltage electrical installations.

When installing the EPX-XT1N-TM0404 within an ABB Protecta Power distribution board, suitable mounting components, terminal connections and protective covers must be selected. Electrical designers should verify prospective fault current, conductor sizing, neutral arrangements and protective device coordination before commissioning.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial low-voltage electrical distribution systems.
  • Industrial electrical switchboards and distribution panels.
  • 40 A four-pole outgoing feeder protection.
  • Three-phase and neutral distribution circuits.
  • Building services and mechanical plant distribution.
  • Manufacturing and industrial facility electrical infrastructure.
  • Commercial switchboards and sub-distribution assemblies.
  • Electrical panel building and switchboard manufacturing.
  • Distribution circuits requiring thermal-magnetic overload and short-circuit protection.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker series SACE Tmax XT
Circuit breaker frame XT1
Performance level XT1N
Frame configuration XT1N160
ABB order code 1SDX253689R1
Product type Moulded case circuit breaker (MCCB)
Rated current 40 A
Maximum frame rating 160 A
Number of poles 4P (four pole)
Short-circuit breaking capacity 36 kA
Trip unit designation TMA
Trip technology Thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Nominal width 110 mm
Rated insulation voltage (Ui) 800 V
Rated impulse withstand voltage (Uimp) 8 kV
Applicable standard IEC 60947-2
Installation type Electrical distribution board / switchboard mounting
Compatible system ABB Protecta Power
Product category Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT1N-TM0404 used for?

The ABB EPX-XT1N-TM0404 is a 40 A four-pole moulded case circuit breaker designed to protect commercial and industrial low-voltage electrical distribution circuits against overloads and short circuits.

What is the rated current of the EPX-XT1N-TM0404?

The EPX-XT1N-TM0404 has a 40 A rated current and uses the ABB SACE Tmax XT1N160 platform, which has a maximum frame rating of 160 A.

What is the breaking capacity of this circuit breaker?

The EPX-XT1N-TM0404 is specified with a 36 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the operating voltage and prospective fault current of the electrical installation.

What does TMA mean on the ABB EPX-XT1N-TM0404?

TMA identifies a thermal-magnetic trip arrangement combining thermal overload protection with magnetic short-circuit protection. These functions help safeguard electrical conductors and connected equipment against excessive current and fault conditions.

What is the advantage of a four-pole MCCB?

A four-pole MCCB can switch three phase conductors and a neutral conductor together, making it suitable for compatible three-phase and neutral distribution systems where four-pole switching is required. The neutral protection arrangement must be checked for the specific installation.

What is the difference between the EPX-XT1N-TM0254 and EPX-XT1N-TM0404?

Both circuit breakers use the ABB SACE Tmax XT1N four-pole platform and have a specified breaking capacity of 36 kA. The EPX-XT1N-TM0254 has a rated current of 25 A, while the EPX-XT1N-TM0404 is rated at 40 A.

What is the nominal width of the EPX-XT1N-TM0404?

The ABB EPX-XT1N-TM0404 uses the four-pole XT1 frame arrangement with a nominal width of 110 mm. Additional clearance may be required depending on the mounting arrangement and accessories.

Can the EPX-XT1N-TM0404 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT1N-TM0404 belongs to the ABB Protecta Power Devices range and is intended for compatible electrical distribution assemblies. Appropriate XT1 mounting components, terminal connections, covers and installation accessories must be selected according to the switchboard configuration.

Trusted ABB Circuit Protection for Electrical Distribution

ABB SACE Tmax XT moulded case circuit breakers provide dependable overload and short-circuit protection for commercial and industrial electrical installations. The EPX-XT1N-TM0404 combines a 40 A four-pole XT1N circuit breaker with 36 kA breaking capacity and TMA thermal-magnetic protection, delivering a compact solution for compatible ABB Protecta Power distribution assemblies.