1SDX253688R1 ABB EPX-XT1N-TM0254 25A 4P 36kA MCCB TMA

1SDX253688R1 ABB EPX-XT1N-TM0254 25A 4P 36kA MCCB TMA

ABB EPX-XT1N-TM0254 is a 25 A four-pole SACE Tmax XT1N moulded case circuit breaker with 36 kA breaking capacity and TMA thermal-magnetic protection for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX253688R1Alt SKU: EPX-XT1N-TM0254MPN: 1SDX253688R1
Price
List Price £468.53 ex VAT
Your Price (ex VAT)
£468.53
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £468.53
Trade pricing is personalised to your account

Manufacturer Lead Time

£468.53

Why Choose the ABB EPX-XT1N-TM0254 Protecta Power Circuit Breaker?

The ABB EPX-XT1N-TM0254 is a compact and dependable 25 A four-pole moulded case circuit breaker (MCCB) designed to provide overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Part of the ABB Protecta Power Devices range, this circuit breaker incorporates the ABB SACE Tmax XT1N platform with a TMA thermal-magnetic trip arrangement, offering reliable circuit protection for compatible electrical distribution assemblies.

Featuring a 36 kA short-circuit breaking capacity, the EPX-XT1N-TM0254 is designed to interrupt electrical faults while helping protect cables, switchgear and connected equipment. Its thermal-magnetic protection system combines thermal overload protection with magnetic short-circuit protection, providing an effective solution for appropriately designed low-voltage distribution circuits.

With a 25 A rated current, four-pole configuration and ABB Tmax XT1N160 frame, this MCCB is suitable for three-phase distribution systems requiring a four-pole switching arrangement. Its compact 110 mm nominal width supports efficient installation in compatible ABB Protecta Power switchboards, making it a practical choice for electrical contractors, panel builders and maintenance engineers.

Key Advantages

  • 25 A rated current provides protection for appropriately designed low-voltage electrical circuits.
  • Four-pole (4P) configuration supports simultaneous switching of three phase conductors and a neutral conductor where required.
  • 36 kA short-circuit breaking capacity provides protection against significant prospective fault currents.
  • TMA thermal-magnetic protection combines overload and short-circuit protection in one device.
  • ABB SACE Tmax XT1N platform provides reliable switching and protective performance.
  • Compact 110 mm nominal width helps optimise space within electrical distribution assemblies.
  • Thermal-magnetic protection operates without requiring an external auxiliary power supply.
  • Designed for integration into compatible ABB Protecta Power distribution boards.

Key Features

  • ABB Protecta Power Devices product family.
  • EPX-XT1N-TM0254 model designation.
  • ABB SACE Tmax XT1N moulded case circuit breaker platform.
  • 25 A rated current.
  • XT1N160 frame with a maximum frame rating of 160 A.
  • Four-pole (4P) circuit breaker construction.
  • 36 kA short-circuit breaking capacity.
  • TMA thermal-magnetic trip arrangement.
  • Thermal overload protection against sustained excessive current.
  • Magnetic short-circuit protection for rapid fault interruption.
  • Four-pole switching capability for compatible three-phase and neutral distribution systems.
  • Manual operating mechanism for circuit switching and resetting.
  • 110 mm nominal width for the four-pole XT1 configuration.
  • Suitable for low-voltage AC electrical distribution systems.
  • Compatible with appropriately selected ABB Tmax XT1 mounting and connection accessories.

Reliable Thermal-Magnetic Protection for Four-Pole Distribution

The ABB EPX-XT1N-TM0254 incorporates TMA thermal-magnetic protection to safeguard electrical installations against sustained overloads and short-circuit faults. The thermal protection element responds to excessive current over time, helping prevent overheating of electrical conductors and connected equipment. The magnetic protection element responds rapidly to high fault currents, enabling prompt circuit disconnection.

The four-pole construction supports applications where three phase conductors and a neutral conductor must be switched together. This arrangement can be particularly useful in compatible three-phase distribution systems where neutral disconnection is required by the electrical design. The neutral pole's protection characteristics and suitability must be verified against the selected circuit breaker configuration and installation requirements.

The ABB SACE Tmax XT1N160 platform provides a compact moulded case design for commercial and industrial power distribution. Its nominal four-pole width of 110 mm supports efficient use of switchboard space while retaining the switching and protection functions required for low-voltage distribution applications.

When installing the EPX-XT1N-TM0254 within an ABB Protecta Power distribution board, suitable mounting components, terminals and protective covers must be selected. Electrical designers should verify prospective fault current, conductor sizing, neutral arrangements and protective device coordination before commissioning.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial low-voltage electrical distribution systems.
  • Industrial electrical switchboards and distribution panels.
  • 25 A four-pole outgoing feeder protection.
  • Three-phase and neutral distribution circuits.
  • Building services and mechanical plant distribution.
  • Manufacturing and industrial facility electrical infrastructure.
  • Commercial switchboards and sub-distribution assemblies.
  • Electrical panel building and switchboard manufacturing.
  • Distribution circuits requiring thermal-magnetic overload and short-circuit protection.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker series SACE Tmax XT
Circuit breaker frame XT1
Performance level XT1N
Frame configuration XT1N160
ABB order code 1SDX253688R1
Product type Moulded case circuit breaker (MCCB)
Rated current 25 A
Maximum frame rating 160 A
Number of poles 4P (four pole)
Short-circuit breaking capacity 36 kA
Trip unit designation TMA
Trip technology Thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Nominal width 110 mm
Rated insulation voltage (Ui) 800 V
Rated impulse withstand voltage (Uimp) 8 kV
Applicable standard IEC 60947-2
Installation type Electrical distribution board / switchboard mounting
Compatible system ABB Protecta Power
Product category Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT1N-TM0254 used for?

The ABB EPX-XT1N-TM0254 is a 25 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.

What is the rated current of the EPX-XT1N-TM0254?

The EPX-XT1N-TM0254 has a 25 A rated current and uses the ABB SACE Tmax XT1N160 platform, which has a maximum frame rating of 160 A.

What is the breaking capacity of this circuit breaker?

The EPX-XT1N-TM0254 is specified with a 36 kA short-circuit breaking capacity. The applicable breaking capacity must be checked against the operating voltage and prospective fault current of the electrical installation.

What does TMA mean on the ABB EPX-XT1N-TM0254?

TMA identifies a thermal-magnetic trip arrangement combining thermal overload protection with magnetic short-circuit protection. These functions help protect electrical conductors and connected equipment against excessive current and fault conditions.

What is the advantage of a four-pole MCCB?

A four-pole MCCB can switch three phase conductors and a neutral conductor together, making it suitable for compatible three-phase and neutral distribution systems where four-pole switching is required. The neutral protection arrangement must be checked for the specific installation.

What is the difference between the EPX-XT1N-TM0253 and EPX-XT1N-TM0254?

Both circuit breakers use the ABB SACE Tmax XT1N platform and have a rated current of 25 A with a specified breaking capacity of 36 kA. The EPX-XT1N-TM0253 is a three-pole model, while the EPX-XT1N-TM0254 is a four-pole model.

What is the nominal width of the EPX-XT1N-TM0254?

The ABB EPX-XT1N-TM0254 uses the four-pole XT1 frame arrangement with a nominal width of 110 mm. Additional clearance may be required depending on the mounting arrangement and accessories.

Can the EPX-XT1N-TM0254 be installed in ABB Protecta Power distribution boards?

Yes. The EPX-XT1N-TM0254 belongs to the ABB Protecta Power Devices range and is intended for compatible electrical distribution assemblies. Appropriate XT1 mounting components, terminal connections, covers and installation accessories must be selected according to the switchboard configuration.

Trusted ABB Circuit Protection for Electrical Distribution

ABB SACE Tmax XT moulded case circuit breakers provide dependable overload and short-circuit protection for commercial and industrial electrical installations. The EPX-XT1N-TM0254 combines a 25 A four-pole XT1N160 circuit breaker with 36 kA breaking capacity and TMA thermal-magnetic protection, delivering a compact solution for compatible ABB Protecta Power distribution assemblies.