Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT1N-TM0204 is a 20 A four-pole 36 kA thermal-magnetic moulded case circuit breaker from the Protecta Power Devices range, designed for overload and short-circuit protection in low-voltage electrical distribution systems.
£468.53
The ABB EPX-XT1N-TM0204 is a compact and dependable 20 A four-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the proven ABB SACE Tmax XT1N circuit breaker platform, it provides effective electrical protection for commercial buildings, industrial installations and distribution board applications.
This circuit breaker uses thermal-magnetic protection technology to safeguard electrical circuits, cables and connected equipment against excessive current and fault conditions. Its four-pole configuration allows simultaneous switching of three phase conductors and a neutral conductor, making it suitable for three-phase electrical distribution systems requiring four-pole isolation.
With a rated current of 20 A, a four-pole configuration and a specified 36 kA breaking capacity, the EPX-XT1N-TM0204 provides dependable protection for outgoing circuits and distribution feeders. Its compact 110 mm-wide XT1 frame supports space-efficient installation within compatible ABB Protecta Power distribution boards and electrical enclosures.
Moulded case circuit breakers such as the ABB EPX-XT1N-TM0204 protect electrical installations by automatically interrupting current when overload or short-circuit conditions occur. The thermal protection element responds to sustained excessive current, helping prevent overheating of cables and connected equipment. The magnetic protection element responds rapidly to high-current faults, helping minimise potential damage and improve electrical installation safety.
The ABB SACE Tmax XT1N series combines compact construction with established circuit protection technology. Its four-pole design supports the coordinated switching of three phase conductors and a neutral conductor, while the compact frame makes it practical for distribution boards where installation space is limited. As part of the ABB Protecta Power Devices range, the EPX-XT1N-TM0204 provides a suitable solution for protecting outgoing feeders and distribution circuits when correctly selected for the installation's voltage, prospective fault current and protection coordination requirements.
| Product range | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT1 |
| ABB order code | 1SDX253687R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame designation | XT1N |
| Frame size | 160 A |
| Rated current (In) | 20 A |
| Number of poles | 4 |
| Specified breaking capacity | 36 kA |
| Trip technology | Thermal-magnetic |
| Manufacturer breaker designation | XT1N 160 TMF 20-450 4P F F + Acc |
| Magnetic trip setting | 450 A |
| Protection functions | Overload and short-circuit protection |
| Electrical system | Low-voltage AC distribution |
| Mounting arrangement | Fixed installation |
| Nominal width | 110 mm |
| Operating mechanism | Manual toggle operation |
| Application | Circuit protection, switching and isolation |
| Product family standard | IEC/EN 60947-2 |
The ABB EPX-XT1N-TM0204 is a four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial distribution boards, including compatible ABB Protecta Power assemblies.
The circuit breaker has a 20 A rated current and belongs to the ABB Tmax XT1N 160 A frame family. The frame rating identifies the maximum current class of the breaker platform rather than the rated current of this individual device.
The EPX-XT1N-TM0204 has a specified 36 kA breaking capacity. The applicable voltage and short-circuit rating conditions should be checked against the electrical installation requirements.
The breaker incorporates thermal-magnetic protection. Its thermal element provides overload protection, while its magnetic element provides short-circuit protection. The manufacturer's TMF 20-450 designation identifies the 20 A thermal rating and 450 A magnetic trip setting.
The four-pole (4P) configuration allows switching of three phase conductors and a neutral conductor, making the breaker suitable for appropriately designed three-phase distribution systems requiring four-pole isolation.
Yes. The EPX-XT1N-TM0204 is part of the ABB Protecta Power Devices range and is intended for integration into compatible electrical distribution assemblies. Appropriate mounting hardware, electrical connections and enclosure compatibility should be verified before installation.
ABB SACE Tmax XT moulded case circuit breakers provide established thermal-magnetic protection technology for commercial and industrial electrical distribution, supporting dependable circuit protection, compact installation and effective integration into modern low-voltage distribution assemblies.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.