ABB EPX-XT1N-TM0164 is a 16 A four-pole 36 kA thermal-magnetic moulded case circuit breaker from the Protecta Power Devices range, designed for overload and short-circuit protection in low-voltage electrical distribution systems.
£468.53
The ABB EPX-XT1N-TM0164 is a compact and reliable 16 A four-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, incorporating the proven ABB SACE Tmax XT1N circuit breaker platform, it is designed for safe and efficient circuit protection in commercial and industrial electrical installations.
This circuit breaker combines thermal-magnetic protection with a robust moulded case construction to help safeguard electrical circuits, cables and connected equipment against excessive current and fault conditions. Its four-pole configuration supports the switching and isolation of three-phase circuits with a neutral conductor, making it particularly suitable for distribution boards, panelboards and electrical control assemblies.
With a rated current of 16 A, a four-pole configuration and a specified 36 kA breaking capacity, the EPX-XT1N-TM0164 provides an effective protection solution for low-voltage power distribution applications. Its compact XT1 frame facilitates installation within ABB Protecta Power distribution equipment and compatible electrical enclosures.
Moulded case circuit breakers such as the ABB EPX-XT1N-TM0164 protect electrical installations by interrupting current when overload or short-circuit conditions occur. The thermal protection element responds to sustained excessive current, while the magnetic protection element provides rapid tripping during high-current fault conditions. Together, these functions help reduce the risk of cable overheating, equipment damage and electrical distribution failures.
The ABB Tmax XT1N platform combines compact construction with established circuit protection technology. The four-pole arrangement makes this breaker suitable for installations requiring coordinated switching of three phases and a neutral conductor. Its integration with ABB Protecta Power equipment supports practical circuit protection arrangements in distribution boards and panel assemblies. Appropriate cable sizing, protective coordination and verification of the installation's prospective fault current remain essential when selecting the breaker.
| Product range | Protecta Power Devices |
|---|---|
| Circuit breaker series | SACE Tmax XT1 |
| ABB order code | 1SDX253686R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame designation | XT1N |
| Frame size | 160 A |
| Rated current (In) | 16 A |
| Number of poles | 4 |
| Specified breaking capacity | 36 kA |
| Trip technology | Thermal-magnetic |
| Protection functions | Overload and short-circuit protection |
| Electrical system | Low-voltage AC distribution |
| Mounting arrangement | Fixed installation within compatible distribution assemblies |
| Nominal four-pole device width | 110 mm |
| Operating mechanism | Manual toggle operation |
| Application | Circuit protection, switching and isolation |
| Product family standard | IEC/EN 60947-2 |
The ABB EPX-XT1N-TM0164 is a four-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial distribution boards, including compatible ABB Protecta Power assemblies.
The circuit breaker has a 16 A rated current and belongs to the ABB Tmax XT1N 160 A frame family. The frame rating identifies the circuit breaker platform and does not change the individual device's 16 A current rating.
The EPX-XT1N-TM0164 has a specified 36 kA breaking capacity. The applicable voltage and short-circuit rating conditions must be checked against the installation requirements.
The breaker incorporates thermal-magnetic protection. Its thermal element provides overload protection, while its magnetic element responds to short-circuit fault currents.
The four-pole (4P) configuration provides switching for three phase conductors and a neutral conductor, making the device suitable for appropriately designed three-phase distribution systems requiring four-pole isolation.
Yes. The EPX-XT1N-TM0164 is listed within the ABB Protecta Power Devices range and is intended for use in compatible distribution assemblies. The appropriate mounting arrangement, connections and enclosure configuration should be verified during installation.
ABB SACE Tmax XT moulded case circuit breakers provide established thermal-magnetic protection technology for commercial and industrial power distribution, supporting dependable circuit protection, practical installation and efficient integration into modern electrical distribution assemblies.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.