ABB EPX-XT5N-TM6303 is a 630 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and thermal-magnetic TMA protection, designed for high-current commercial and industrial low-voltage electrical distribution systems.
£1,967.65
The ABB EPX-XT5N-TM6303 is a robust, high-performance 630 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial electrical distribution systems. As part of the ABB Protecta Power Devices range, this circuit breaker combines thermal-magnetic protection technology with a 36 kA short-circuit breaking capacity, making it suitable for demanding low-voltage power distribution applications.
Based on the ABB SACE Tmax XT5N circuit breaker platform, the EPX-XT5N-TM6303 is engineered for dependable electrical protection and integration into compatible distribution assemblies. Its TMA thermal-magnetic trip unit provides protection against sustained overloads and high short-circuit currents, helping safeguard electrical infrastructure, cables and connected equipment. The XT5 frame combines high current-carrying capability with robust mechanical construction and flexible protection settings.
With a 630 A rated current, three-pole configuration and 36 kA ultimate short-circuit breaking capacity at 380–415 V AC, the ABB EPX-XT5N-TM6303 is suitable for appropriately designed three-phase distribution circuits, high-current outgoing feeders and industrial power distribution systems. Identified by ABB order code 1SDX253490R1, this MCCB belongs to the Protecta Power range and is intended for use with compatible ABB electrical distribution equipment.
Moulded case circuit breakers such as the ABB EPX-XT5N-TM6303 provide essential protection for high-current electrical distribution circuits. They automatically interrupt the electrical supply when overload or short-circuit conditions cause the protective trip mechanism to operate. This helps reduce the risk of excessive conductor heating, damage to electrical equipment and disruption caused by electrical faults.
The TMA thermal-magnetic protection system combines two complementary protective functions. The thermal element responds to sustained overload currents, while the magnetic element provides rapid operation during high short-circuit current conditions. The XT5N 630 TMA configuration incorporates adjustable protection settings, including a 3150–6300 A magnetic trip adjustment range, allowing the protective response to be coordinated with the requirements of appropriately designed electrical installations.
The ABB SACE Tmax XT5N platform is designed for substantial low-voltage distribution duties. The EPX-XT5N-TM6303 provides a 630 A current rating and a 36 kA ultimate short-circuit breaking capacity at 380–415 V AC. The XT5N platform also offers a rated service short-circuit breaking capacity equal to 100% of its ultimate breaking capacity at this voltage range, supporting dependable protective performance in demanding electrical installations.
As part of the ABB Protecta Power distribution system, the EPX-XT5N-TM6303 is intended for integration into compatible electrical panelboard assemblies using the appropriate mounting and connection components. Its robust XT5 construction, thermal-magnetic protection and high current rating make it a practical choice for electrical contractors, panel builders, facilities engineers and industrial maintenance professionals. Final circuit breaker selection must account for prospective fault current, installation voltage, cable ratings, protection coordination and applicable electrical standards.
| Product group | Protecta Power Devices |
|---|---|
| Series | Protecta Power / SACE Tmax XT5N |
| ABB order code | 1SDX253490R1 |
| Underlying ABB XT5N breaker reference | 1SDA100347R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 630 A |
| Number of poles | 3 |
| Electrical configuration | Three-phase |
| Rated ultimate short-circuit breaking capacity (Icu) | 36 kA at 380–415 V AC |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu at 380–415 V AC |
| Protection technology | Thermal-magnetic |
| Trip unit designation | TMA |
| Rated trip unit current | 630 A |
| Magnetic short-circuit adjustment range | 3150–6300 A |
| Protection functions | Overload and instantaneous short-circuit protection |
| Frame family | XT5 |
| Frame current class | 630 A |
| Frame performance designation | N |
| Rated frequency | 50/60 Hz |
| Operating mechanism | Manual switching with automatic protective tripping |
| Breaker construction | Fixed moulded case circuit breaker |
| Underlying breaker terminal arrangement | Front terminals |
| Mounting application | Compatible electrical distribution assemblies |
| Application category | Low-voltage electrical power distribution |
| Typical installation | ABB Protecta Power panelboards and compatible distribution equipment |
The ABB EPX-XT5N-TM6303 is a three-pole moulded case circuit breaker designed to protect high-current low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.
The circuit breaker has a rated current of 630 A. Its XT5N TMA thermal-magnetic trip unit provides overload protection and adjustable magnetic short-circuit protection for appropriately designed high-current electrical circuits.
The ABB EPX-XT5N-TM6303 has a 36 kA rated ultimate short-circuit breaking capacity at 380–415 V AC. The XT5N platform also provides a rated service short-circuit breaking capacity equal to 100% of Icu at this voltage range. Suitability must be assessed against the prospective fault current and operating conditions of the installation.
This MCCB incorporates a thermal-magnetic (TMA) trip unit. The thermal element provides protection against sustained overloads, while the magnetic element provides rapid protection against high short-circuit currents. The XT5N 630 TMA configuration supports an adjustable magnetic trip threshold of 3150–6300 A.
The circuit breaker is intended for installation within compatible ABB Protecta Power panelboards and electrical distribution assemblies. It is suitable for high-current three-phase outgoing circuits and industrial power distribution applications, with appropriate mounting and connection components selected for the installation.
ABB Protecta Power protective devices combine established circuit protection technology with practical high-capacity electrical distribution solutions. The EPX-XT5N-TM6303 offers a robust 630 A, three-pole XT5N MCCB configuration with thermal-magnetic protection and a 36 kA breaking capacity, supporting dependable protection in demanding commercial and industrial low-voltage distribution installations.