ABB EPX-XT5N-TM4003 is a 400 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and adjustable thermal-magnetic protection, designed for commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX253489R1Alt SKU: EPX-XT5N-TM4003MPN: 1SDX253489R1
Price
List Price £1,287.73 ex VAT
Your Price (ex VAT)
£1,287.73
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,287.73
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,287.73

Why Choose the ABB EPX-XT5N-TM4003 400A 3-Pole MCCB?

The ABB EPX-XT5N-TM4003 is a robust, high-performance 400 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial electrical distribution systems. As part of the ABB Protecta Power Devices range, this circuit breaker combines proven thermal-magnetic protection technology with a 36 kA short-circuit breaking capacity, making it suitable for demanding low-voltage power distribution applications.

Based on the advanced ABB SACE Tmax XT5N circuit breaker platform, the EPX-XT5N-TM4003 is engineered for dependable electrical protection and integration into compatible distribution assemblies. Its TMA thermal-magnetic trip unit provides protection against sustained overloads and high short-circuit currents, helping safeguard electrical infrastructure, cables and connected equipment. The XT5 frame combines high current-carrying capability with robust mechanical construction and practical installation flexibility.

With a 400 A rated current, three-pole configuration and 36 kA breaking capacity at 380–415 V AC, the ABB EPX-XT5N-TM4003 is suitable for appropriately designed three-phase distribution circuits, high-current outgoing feeders and industrial power distribution systems. Identified by ABB order code 1SDX253489R1, this MCCB belongs to the Protecta Power range and is intended for use with compatible ABB electrical distribution equipment.

Key Advantages

  • High-capacity 400 A moulded case circuit breaker for commercial and industrial electrical distribution.
  • Three-pole protection suitable for three-phase power distribution circuits.
  • 36 kA short-circuit breaking capacity at 380–415 V AC for installations with significant prospective fault currents.
  • Integrated thermal-magnetic (TMA) trip unit provides overload and short-circuit protection.
  • Adjustable thermal and magnetic protection within the capabilities of the XT5 TMA trip unit.
  • Robust ABB SACE Tmax XT5N frame designed for demanding low-voltage distribution applications.
  • Part of the ABB Protecta Power Devices range for professional electrical distribution systems.
  • High current-carrying capability suitable for substantial electrical feeders and distribution circuits.
  • Common operating mechanism provides simultaneous switching of all three protected phases.
  • Compatible with appropriately specified ABB Protecta Power panelboards and mounting arrangements.
  • Automatic fault interruption helps reduce the risk of electrical equipment damage and excessive conductor heating.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT5N-TM4003 product designation.
  • 400 A rated current for high-capacity electrical circuit protection.
  • Three-pole (3P) configuration for three-phase electrical distribution.
  • 36 kA rated ultimate short-circuit breaking capacity at 380–415 V AC.
  • Thermal-magnetic TMA trip unit for overload and short-circuit protection.
  • Adjustable thermal overload setting for coordination with appropriately designed circuits.
  • Adjustable magnetic short-circuit setting for fault protection requirements.
  • ABB SACE Tmax XT5N platform with N breaking-capacity classification.
  • XT5 400 A frame configuration designed for high-current distribution applications.
  • Manual switching mechanism with automatic protective tripping.
  • Common three-pole operating mechanism for coordinated phase switching.
  • Robust moulded case construction suitable for industrial electrical environments.
  • Designed for integration into compatible ABB Protecta Power electrical distribution assemblies.

Reliable High-Current Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT5N-TM4003 provide essential protection for high-current electrical distribution circuits. They automatically interrupt the electrical supply when overload or short-circuit conditions cause the protective trip mechanism to operate. This helps reduce the risk of excessive conductor heating, damage to electrical equipment and disruption caused by electrical faults.

The TMA thermal-magnetic protection system combines two complementary protective functions. The thermal element responds to sustained overload currents, while the magnetic element provides rapid operation during high short-circuit current conditions. The XT5 TMA trip unit incorporates adjustable protection settings, allowing the protective response to be coordinated with the requirements of appropriately designed electrical installations.

The ABB SACE Tmax XT5N platform is designed for substantial low-voltage distribution duties. The EPX-XT5N-TM4003 provides a 400 A current rating and a 36 kA ultimate short-circuit breaking capacity at 380–415 V AC. The XT5N platform also offers a rated service short-circuit breaking capacity equal to 100% of its ultimate breaking capacity at this voltage range, supporting dependable protective performance in demanding electrical installations.

As part of the ABB Protecta Power distribution system, the EPX-XT5N-TM4003 is intended for integration into compatible electrical panelboard assemblies using the appropriate mounting and connection components. Its robust XT5 construction, adjustable thermal-magnetic protection and high current rating make it a practical choice for electrical contractors, panel builders, facilities engineers and industrial maintenance professionals. Final circuit breaker selection must account for prospective fault current, installation voltage, cable ratings, protection coordination and applicable electrical standards.

Typical Applications

  • Commercial and industrial electrical distribution systems.
  • ABB Protecta Power panelboards and compatible assemblies.
  • High-current three-phase outgoing feeder protection.
  • Industrial low-voltage switchboards and distribution panels.
  • Manufacturing and production facilities.
  • Large commercial buildings and office complexes.
  • Warehouses, logistics centres and distribution facilities.
  • Building services and mechanical plant power distribution.
  • Electrical sub-distribution and high-capacity feeder circuits.
  • Infrastructure and utilities electrical distribution installations.
  • Protection of appropriately rated industrial electrical equipment and feeders.
  • Electrical infrastructure upgrades, maintenance and replacement projects.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power / SACE Tmax XT5N
ABB order code 1SDX253489R1
Product type Moulded case circuit breaker (MCCB)
Rated current 400 A
Number of poles 3
Electrical configuration Three-phase
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 380–415 V AC
Rated service short-circuit breaking capacity (Ics) 100% of Icu at 380–415 V AC
Protection technology Thermal-magnetic
Trip unit designation TMA
Rated trip unit current 400 A
Thermal overload adjustment range 280–400 A
Magnetic short-circuit adjustment range 2,000–4,000 A
Protection functions Adjustable overload and instantaneous short-circuit protection
Frame family XT5
Frame current class 400 A
Frame performance designation N
Rated frequency 50/60 Hz
Operating mechanism Manual switching with automatic protective tripping
Mounting application Compatible electrical distribution assemblies
Application category Low-voltage electrical power distribution
Typical installation ABB Protecta Power panelboards and compatible distribution equipment

Frequently Asked Questions

What is the ABB EPX-XT5N-TM4003 used for?

The ABB EPX-XT5N-TM4003 is a three-pole moulded case circuit breaker designed to protect high-current low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.

What is the rated current of the ABB EPX-XT5N-TM4003?

The circuit breaker has a rated current of 400 A. Its XT5 TMA thermal-magnetic trip unit provides adjustable thermal overload protection, allowing the protection settings to be coordinated with appropriately designed electrical circuits.

What is the breaking capacity of this MCCB?

The ABB EPX-XT5N-TM4003 has a 36 kA rated ultimate short-circuit breaking capacity at 380–415 V AC. The XT5N platform also provides a rated service short-circuit breaking capacity equal to 100% of Icu at this voltage range. Suitability must be assessed against the prospective fault current and operating conditions of the installation.

What type of protection does the EPX-XT5N-TM4003 provide?

This MCCB incorporates an adjustable thermal-magnetic (TMA) trip unit. The thermal element provides protection against sustained overloads, while the magnetic element provides rapid protection against high short-circuit currents. The XT5 400 A TMA configuration supports thermal adjustment from 280–400 A and magnetic adjustment from 2,000–4,000 A.

Where is the ABB EPX-XT5N-TM4003 typically installed?

The circuit breaker is intended for installation within compatible ABB Protecta Power panelboards and electrical distribution assemblies. It is commonly specified for high-current three-phase outgoing circuits and industrial power distribution applications, with appropriate mounting and connection components selected for the installation.

Trusted by Electrical Professionals Worldwide

ABB Protecta Power protective devices combine established circuit protection technology with practical high-capacity electrical distribution solutions. The EPX-XT5N-TM4003 offers a robust 400 A, three-pole XT5N MCCB configuration with adjustable thermal-magnetic protection and a 36 kA breaking capacity, supporting dependable protection in demanding commercial and industrial low-voltage distribution installations.