1SDX253488R1 ABB EPX-XT5N-TM3203 320A 3P 36kA TMA Moulded Case Circuit Breaker

1SDX253488R1 ABB EPX-XT5N-TM3203 320A 3P 36kA TMA Moulded Case Circuit Breaker

ABB EPX-XT5N-TM3203 (1SDX253488R1) is a 320 A three-pole SACE Tmax XT5N moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and thermal-magnetic adjustable protection for compatible ABB Protecta Power electrical distribution systems.

SKU: 1SDX253488R1Alt SKU: EPX-XT5N-TM3203MPN: 1SDX253488R1
Price
List Price £1,287.73 ex VAT
Your Price (ex VAT)
£1,287.73
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,287.73
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,287.73

Why Choose the ABB EPX-XT5N-TM3203 320A 3-Pole Moulded Case Circuit Breaker?

The ABB EPX-XT5N-TM3203 is a high-capacity 320 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT5N400 circuit breaker platform, this protective device combines substantial current-carrying capability, dependable thermal-magnetic protection and robust construction for demanding power distribution applications.

As part of the ABB Protecta Power Devices product group, the EPX-XT5N-TM3203 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its thermal-magnetic adjustable (TMA) trip configuration provides protection against sustained overload conditions and short-circuit faults, helping protect electrical cables, connected equipment and distribution infrastructure. The three-pole construction enables coordinated switching and protection of all three phase conductors in suitable three-phase installations.

With a rated current of 320 A, a specified 36 kA short-circuit breaking capacity and a three-pole (3P) configuration, the EPX-XT5N-TM3203 is particularly suited to higher-current outgoing feeders, commercial sub-distribution systems and industrial electrical installations. Its compact 140 mm nominal device width helps optimise available space within compatible distribution boards, making it a practical choice for electrical contractors, panel builders, switchboard manufacturers and facilities engineers.

Key Advantages

  • High-capacity 320 A moulded case circuit breaker for commercial and industrial electrical distribution.
  • 36 kA short-circuit breaking capacity in the specified ABB Protecta Power configuration.
  • Three-pole (3P) construction for coordinated switching and protection of three-phase circuits.
  • Thermal-magnetic adjustable (TMA) protection against sustained overloads and short-circuit faults.
  • Adjustable thermal overload protection supports appropriate coordination with connected cables and electrical equipment.
  • Based on the established ABB SACE Tmax XT5N400 circuit breaker platform.
  • 400 A frame rating provides a robust platform for the 320 A protective device.
  • Compact 140 mm nominal width helps conserve valuable distribution board space.
  • Designed for integration into ABB Protecta Power distribution boards.
  • Suitable for higher-current outgoing feeder protection and three-phase power distribution.
  • Robust moulded case construction supports dependable performance in demanding electrical environments.
  • Suitable for new installations, distribution board upgrades and industrial power distribution projects.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT5N-TM3203 product designation.
  • ABB order code 1SDX253488R1.
  • ABB SACE Tmax XT5N400 circuit breaker platform.
  • 320 A rated current for higher-capacity outgoing circuit protection.
  • 400 A frame rating within the XT5N400 platform.
  • 36 kA specified short-circuit breaking capacity for compatible ABB Protecta Power applications.
  • Three-pole (3P) configuration for simultaneous switching of three phase conductors.
  • Thermal-magnetic adjustable (TMA) trip configuration for overload and short-circuit protection.
  • Thermal overload protection responds to sustained excessive current.
  • Adjustable thermal protection supports coordination with appropriately rated distribution circuits.
  • Magnetic short-circuit protection provides rapid fault interruption.
  • 140 mm nominal device width for efficient use of distribution board space.
  • Manual operating mechanism for circuit switching and isolation when correctly installed.
  • Designed for installation using compatible ABB Protecta Power mounting and connection accessories.
  • Suitable for commercial, industrial and building services electrical distribution systems.

Reliable High-Current Circuit Protection for Three-Phase Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT5N-TM3203 protect electrical distribution systems by automatically interrupting current when overload or short-circuit conditions occur. The thermal protection element responds to sustained excessive current, while the magnetic protection element operates rapidly during short-circuit faults. This combined protection helps reduce the risk of cable damage, electrical equipment failure and disruption to essential power distribution infrastructure.

The ABB SACE Tmax XT5N400 platform provides dependable high-current circuit protection for low-voltage electrical networks. Its three-pole construction enables coordinated switching and protection of all three phase conductors, making the EPX-XT5N-TM3203 suitable for three-phase outgoing feeders, industrial distribution circuits and commercial power distribution systems. The thermal-magnetic trip configuration supports appropriate protection coordination with connected cables, electrical loads and downstream protective devices.

The corresponding ABB XT5N400 320 A TMA circuit breaker configuration uses an adjustable thermal-magnetic release. ABB identifies a 320 A thermal release rating and a magnetic protection setting associated with the 320 A XT5N400 TMA platform. Exact thermal adjustment limits and magnetic trip settings should be confirmed against the specific release fitted to the Protecta Power device before finalising protection coordination.

With a 320 A rated current and a specified 36 kA breaking capacity, the EPX-XT5N-TM3203 is suitable for appropriately designed higher-current electrical distribution circuits. Its 140 mm nominal width supports efficient use of distribution board space without compromising the need for robust circuit protection.

Correct circuit breaker selection should consider the installation operating voltage, prospective short-circuit current, conductor sizing, protective device coordination and distribution board compatibility. The applicable breaking capacity, thermal-magnetic trip settings and mounting accessories should be assessed against the complete electrical installation design and relevant ABB technical documentation.

Typical Applications

  • ABB Protecta Power low-voltage electrical distribution boards.
  • High-current three-phase outgoing feeder protection.
  • Commercial building main and sub-distribution installations.
  • Industrial electrical distribution panels and manufacturing facilities.
  • Three-phase electrical supplies for machinery and industrial equipment.
  • Electrical distribution for warehouses, workshops and logistics centres.
  • Building services infrastructure and mechanical plant electrical supplies.
  • Higher-capacity electrical distribution circuits in commercial facilities.
  • Electrical switchboard manufacturing and power distribution panel assembly.

Technical Specifications

Product group Protecta Power Devices
Series SACE Tmax XT
Circuit breaker platform XT5N400
ABB order code 1SDX253488R1
Product type Moulded case circuit breaker (MCCB)
Rated current 320 A
Frame rating 400 A
Breaking capacity 36 kA (specified Protecta Power application)
Number of poles 3
Pole configuration Three-pole (3P)
Trip configuration Thermal-magnetic adjustable (TMA)
Trip technology Thermal-magnetic
Thermal protection Adjustable overload protection
Magnetic protection Short-circuit protection
Protection functions Overload and short-circuit protection
Applicable circuit breaker standard IEC 60947-2
Nominal device width 140 mm
Mounting type Compatible ABB Protecta Power distribution assembly
Installation Fixed distribution board installation using compatible mounting and connection accessories
Application Three-phase low-voltage electrical power distribution

Frequently Asked Questions

What is the ABB EPX-XT5N-TM3203 used for?

The ABB EPX-XT5N-TM3203 is a 320 A three-pole moulded case circuit breaker designed to protect higher-current three-phase electrical distribution circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems.

What is the rated current and breaking capacity of this circuit breaker?

The EPX-XT5N-TM3203 has a 320 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB XT5N400 platform, which has a 400 A frame rating. The applicable breaking capacity must be assessed against the installation operating voltage and prospective fault current.

What does TMA mean on the ABB EPX-XT5N-TM3203?

TMA stands for Thermal-Magnetic Adjustable. This protection technology combines adjustable thermal overload protection with magnetic short-circuit protection. The thermal protection element responds to sustained excessive current, while the magnetic element provides rapid operation during short-circuit faults. Exact adjustment ranges should be confirmed against the specific ABB XT5N400 trip release fitted to the breaker.

What is the advantage of the three-pole configuration?

The three-pole (3P) configuration enables coordinated switching and protection of three phase conductors. This makes the EPX-XT5N-TM3203 suitable for three-phase electrical distribution circuits and appropriately designed industrial equipment supplies. Unlike a four-pole circuit breaker, it does not provide a dedicated switched neutral pole.

Where is the ABB EPX-XT5N-TM3203 typically installed?

The breaker is designed for installation within compatible ABB Protecta Power distribution boards, where it provides higher-current outgoing feeder protection. The ABB XT5N three-pole platform has a nominal width of 140 mm, supporting efficient distribution board layouts. Compatible mounting, connection and cable management accessories should be selected for the specific installation.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely specified by electrical engineers, contractors and panel builders for dependable low-voltage power distribution. The EPX-XT5N-TM3203 combines 320 A current capacity, three-pole switching, 36 kA specified short-circuit breaking performance and thermal-magnetic adjustable protection to support reliable electrical installations in commercial and industrial ABB Protecta Power distribution systems.