1SDX253486R1 ABB EPX-XT4N-TM2003 200A 3P 36kA MCCB - TMA

1SDX253486R1 ABB EPX-XT4N-TM2003 200A 3P 36kA MCCB – TMA

ABB EPX-XT4N-TM2003 is a 200 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and adjustable TMA thermal-magnetic protection, designed for reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX253486R1Alt SKU: EPX-XT4N-TM2003MPN: 1SDX253486R1
Price
List Price £786.67 ex VAT
Your Price (ex VAT)
£786.67
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £786.67
Trade pricing is personalised to your account

Manufacturer Lead Time

£786.67

Why Choose the ABB EPX-XT4N-TM2003 200A 3-Pole MCCB?

The ABB EPX-XT4N-TM2003 is a robust and reliable 200 A three-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 36 kA short-circuit breaking capacity and a TMA thermal-magnetic trip unit, this circuit breaker belongs to the ABB Protecta Power Devices range and is based on ABB's established Tmax XT4N circuit breaker platform.

Designed for commercial and industrial electrical installations, the EPX-XT4N-TM2003 combines dependable circuit protection with a compact and durable construction suitable for modern power distribution equipment. Its thermal-magnetic protection system responds to sustained overload conditions and high short-circuit currents, helping protect electrical cables, connected equipment and distribution infrastructure against potentially damaging electrical faults.

With a 200 A rated current, three-pole configuration and 36 kA breaking capacity, the ABB EPX-XT4N-TM2003 is particularly suitable for higher-current three-phase outgoing circuits in commercial distribution boards, industrial electrical panels and compatible ABB Protecta Power assemblies. Supplied under ABB order code 1SDX253486R1, this MCCB provides a dependable solution for demanding low-voltage power distribution applications.

Key Advantages

  • Reliable 200 A moulded case circuit breaker designed for commercial and industrial electrical distribution.
  • Three-pole (3P) configuration provides simultaneous switching and protection of three-phase circuits.
  • 36 kA short-circuit breaking capacity for installations requiring substantial fault-current interruption capability.
  • TMA thermal-magnetic trip unit combines overload and short-circuit protection.
  • Adjustable thermal overload protection enables circuit protection settings to be matched to installation requirements.
  • Magnetic short-circuit protection provides rapid interruption during high-current electrical faults.
  • Compact ABB Tmax XT4N frame helps optimise space within electrical distribution assemblies.
  • Designed for integration into compatible ABB Protecta Power distribution systems.
  • Robust mechanical construction supports reliable circuit switching and long-term operation.
  • Suitable for new electrical installations, distribution board upgrades and compatible MCCB replacement applications.

Key Features

  • ABB Protecta Power Devices product group.
  • ABB Tmax XT4N moulded case circuit breaker platform.
  • 200 A rated current.
  • Three-pole (3P) configuration.
  • 36 kA short-circuit breaking capacity at the applicable rated voltage.
  • TMA thermal-magnetic trip unit for overload and short-circuit protection.
  • Adjustable thermal trip setting from 140–200 A.
  • Magnetic short-circuit trip for rapid fault-current interruption.
  • XT4N 250 A frame with a 200 A thermal-magnetic trip unit.
  • Manual toggle-operated switching mechanism with trip indication.
  • Rated operational voltage up to 690 V AC within the XT4N circuit breaker family.
  • IEC/EN 60947-2 circuit breaker design standard.
  • 110 mm three-pole device width for the XT4 Protecta Power arrangement.
  • Designed for installation using compatible ABB Protecta Power XT4 mounting accessories.
  • Suitable for three-phase commercial and industrial low-voltage distribution circuits.
  • ABB manufacturer order code: 1SDX253486R1.

Reliable 200A Circuit Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT4N-TM2003 protect electrical installations by automatically interrupting current when overload or short-circuit conditions occur. By combining normal circuit switching with protective tripping mechanisms, MCCBs help reduce the risk of damage to electrical cables, distribution equipment and connected installations.

The TMA thermal-magnetic trip unit combines two complementary protection principles. The thermal element responds to sustained overload currents, while the magnetic element provides rapid tripping during high-current short circuits. The 140–200 A adjustable thermal setting range allows the overload protection threshold to be selected according to the protected circuit, cable ratings and manufacturer's installation requirements.

The ABB Tmax XT4N 250 A frame platform provides a robust circuit breaker construction suitable for demanding low-voltage distribution applications. The EPX-XT4N-TM2003 uses a 200 A thermal-magnetic trip unit within this frame family, offering three-pole protection for appropriately rated outgoing distribution circuits. The XT4N design supports reliable mechanical operation and circuit protection in commercial and industrial electrical environments.

As part of the ABB Protecta Power Devices range, this MCCB is designed for integration into compatible electrical distribution assemblies. Its 36 kA breaking capacity makes it suitable for installations where the prospective short-circuit current falls within the breaker's verified interruption capability at the relevant operating voltage. The corresponding XT4N 250 frame family supports operation at voltages up to 690 V AC, although the available breaking capacity varies with operating voltage.

For installation within ABB Protecta Power equipment, the appropriate XT4 three-pole mounting arrangement and compatible connection accessories must be selected in accordance with the manufacturer's assembly instructions. Correct circuit breaker selection, conductor sizing and protective settings are essential for safe and dependable electrical distribution.

Typical Applications

  • ABB Protecta Power distribution boards and compatible electrical assemblies.
  • Commercial low-voltage power distribution systems.
  • Industrial electrical distribution panels and switchgear.
  • Three-phase outgoing circuit protection rated up to 200 A.
  • Commercial building electrical sub-distribution boards.
  • Manufacturing facilities and industrial infrastructure.
  • Building services and mechanical plant electrical distribution.
  • Distribution circuits supplying appropriately rated industrial machinery and equipment.
  • Electrical installations requiring adjustable thermal overload and magnetic short-circuit protection.
  • Electrical refurbishment, distribution board upgrades and replacement of compatible ABB MCCBs.

Technical Specifications

Product group Protecta Power Devices
Series Tmax XT4 / Protecta Power
ABB order code 1SDX253486R1
Product type Moulded case circuit breaker (MCCB)
Rated current 200 A
Number of poles 3
Pole configuration 3P
Short-circuit breaking capacity 36 kA
Breaking capacity classification N (normal breaking capacity)
Trip unit type TMA thermal-magnetic
Thermal trip setting range 140–200 A
Overload protection Adjustable thermal trip
Short-circuit protection Magnetic trip
Frame family XT4N
Frame rating 250 A
Rated operational voltage (XT4N frame family) Up to 690 V AC
Rated insulation voltage (XT4N frame family) 1,000 V
Rated impulse withstand voltage (XT4N frame family) 8 kV
Applicable circuit breaker standard IEC/EN 60947-2
Protecta Power device width 110 mm
Application Low-voltage electrical distribution
Installation type Compatible electrical distribution board / switchgear assembly
Operating mechanism Manual toggle-operated circuit breaker
Typical electrical system Three-phase AC distribution

Frequently Asked Questions

What is the ABB EPX-XT4N-TM2003 used for?

The ABB EPX-XT4N-TM2003 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.

What is the rated current of the ABB EPX-XT4N-TM2003?

The EPX-XT4N-TM2003 has a 200 A rated current. It uses a 200 A thermal-magnetic trip unit within the ABB Tmax XT4N 250 A frame family, providing overcurrent protection for appropriately rated electrical distribution circuits.

What is the breaking capacity of this MCCB?

The ABB EPX-XT4N-TM2003 has a specified 36 kA short-circuit breaking capacity. This represents its fault-interruption capability under the applicable rated conditions. The installation voltage and prospective fault current must be checked to confirm suitability, as breaking capacity varies with voltage.

What does TMA thermal-magnetic protection mean?

TMA thermal-magnetic protection combines a thermal overload protection element with a magnetic short-circuit protection element. The thermal mechanism responds to sustained excessive current, while the magnetic mechanism trips rapidly when a sufficiently high short-circuit current occurs.

Can the thermal protection setting be adjusted?

Yes. The corresponding ABB XT4N 200 A TMA trip unit provides an adjustable thermal protection setting within a 140–200 A range. The appropriate setting must be selected according to the protected circuit, conductor ratings and manufacturer's installation requirements.

What is the difference between the 200A trip rating and the 250A frame rating?

The 200 A trip rating identifies the circuit breaker's rated protective current, while the 250 A frame rating identifies the maximum current rating of the XT4N frame platform. The EPX-XT4N-TM2003 is a 200 A protective device and must not be treated as a 250 A rated circuit breaker.

Is the ABB EPX-XT4N-TM2003 suitable for three-phase systems?

Yes. The three-pole (3P) configuration allows the circuit breaker to switch and protect three phase conductors together, making it suitable for appropriately designed three-phase low-voltage distribution circuits.

Where is the ABB EPX-XT4N-TM2003 typically installed?

This MCCB is typically installed within compatible electrical distribution boards, switchgear assemblies and commercial or industrial distribution panels. It is particularly suitable for ABB Protecta Power installations requiring 200 A three-pole outgoing circuit protection.

What is the ABB order code for the EPX-XT4N-TM2003?

The ABB manufacturer order code is 1SDX253486R1. The corresponding product reference is EPX-XT4N-TM2003, identifying the 200 A, three-pole, 36 kA thermal-magnetic MCCB within the ABB Protecta Power Devices range.

Trusted ABB Circuit Protection for Professional Installations

ABB Protecta Power circuit protection devices combine established Tmax XT circuit breaker technology with practical integration into modern electrical distribution systems. The EPX-XT4N-TM2003 provides dependable 200 A three-pole thermal-magnetic protection and a 36 kA breaking capacity for appropriately specified commercial and industrial installations.