Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT4N-TM1603 is a 160 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and TMA thermal-magnetic protection, designed for reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems.
£760.45
The ABB EPX-XT4N-TM1603 is a robust and reliable 160 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 36 kA short-circuit breaking capacity and a TMA thermal-magnetic trip unit, this circuit breaker belongs to the ABB Protecta Power Devices range and is based on ABB's established Tmax XT4N circuit breaker platform.
Designed for commercial and industrial electrical installations, the EPX-XT4N-TM1603 combines effective circuit protection with a compact and durable construction suitable for modern power distribution equipment. Its thermal-magnetic protection system responds to sustained overload conditions and high short-circuit currents, helping safeguard electrical cables, connected equipment and distribution infrastructure against electrical faults.
With a 160 A rated current, three-pole configuration and 36 kA breaking capacity, the ABB EPX-XT4N-TM1603 is particularly suitable for three-phase outgoing circuits in commercial distribution boards, industrial electrical panels and compatible ABB Protecta Power assemblies. Supplied under ABB order code 1SDX253485R1, this MCCB provides a dependable solution for higher-current low-voltage distribution applications.
Moulded case circuit breakers such as the ABB EPX-XT4N-TM1603 protect electrical installations by automatically interrupting current when overload or short-circuit conditions occur. By combining normal circuit switching with protective tripping mechanisms, MCCBs help reduce the risk of damage to electrical cables, distribution equipment and connected installations.
The TMA thermal-magnetic trip unit combines two complementary protection principles. The thermal element responds to sustained overload currents, while the magnetic element provides rapid tripping during high-current short circuits. Adjustable thermal protection allows the circuit breaker to be configured according to the requirements of the protected circuit, subject to the manufacturer's permitted settings and the electrical installation design.
The ABB Tmax XT4N platform provides a robust circuit breaker construction suitable for demanding low-voltage distribution applications. The EPX-XT4N-TM1603 uses a 160 A protective rating within the XT4N frame family, offering three-pole protection for appropriately rated outgoing distribution circuits.
As part of the ABB Protecta Power Devices range, this MCCB is designed for integration into compatible electrical distribution assemblies. Its 36 kA breaking capacity makes it suitable for installations where the prospective short-circuit current falls within the breaker's verified interruption capability at the relevant operating voltage.
For installation within a compatible ABB Protecta Power assembly, the XT4 three-pole outgoing MCCB base plate and cover, reference EPX-BPCXT4-3P, is specified separately. Correct selection of the mounting arrangement, cable connections and protective settings is essential for safe and reliable operation.
| Product group | Protecta Power Devices |
|---|---|
| Series | Tmax XT4 / Protecta Power |
| ABB order code | 1SDX253485R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 160 A |
| Number of poles | 3 |
| Pole configuration | 3P |
| Short-circuit breaking capacity | 36 kA |
| Breaking capacity classification | N (normal breaking capacity) |
| Trip unit type | TMA thermal-magnetic |
| Overload protection | Adjustable thermal trip |
| Short-circuit protection | Magnetic trip |
| Frame family | XT4N |
| Frame rating | 160 A |
| Rated operational voltage (XT4 frame family) | Up to 690 V AC |
| Rated insulation voltage (XT4 frame family) | 1,000 V |
| Rated impulse withstand voltage (XT4 frame family) | 8 kV |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
| Protecta Power device width | 110 mm |
| Compatible outgoing MCCB base plate and cover | EPX-BPCXT4-3P |
| Application | Low-voltage electrical distribution |
| Installation type | Compatible electrical distribution board / switchgear assembly |
| Operating mechanism | Manual toggle-operated circuit breaker |
| Typical electrical system | Three-phase AC distribution |
The ABB EPX-XT4N-TM1603 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.
The EPX-XT4N-TM1603 has a 160 A rated current. Its thermal-magnetic protection system provides overcurrent protection for appropriately rated electrical distribution circuits.
The ABB EPX-XT4N-TM1603 has a specified 36 kA short-circuit breaking capacity. This represents its fault-interruption capability under the applicable rated conditions. The installation voltage and prospective fault current must be checked to confirm suitability.
TMA thermal-magnetic protection combines a thermal overload protection element with a magnetic short-circuit protection element. The thermal mechanism responds to sustained excessive current, while the magnetic mechanism trips rapidly when a sufficiently high short-circuit current occurs.
Yes. The TMA thermal-magnetic trip unit provides adjustable thermal overload protection. The setting must be selected in accordance with the manufacturer's specified adjustment range, cable ratings and electrical installation requirements.
Yes. The three-pole (3P) configuration allows the circuit breaker to switch and protect three phase conductors together, making it suitable for appropriately designed three-phase low-voltage distribution circuits.
For compatible ABB Protecta Power outgoing circuit installations, the designated XT4 three-pole MCCB base plate and cover, reference EPX-BPCXT4-3P, is required and ordered separately. Installation must follow the applicable ABB assembly instructions.
The ABB manufacturer order code is 1SDX253485R1. The corresponding product reference is EPX-XT4N-TM1603, identifying the 160 A, three-pole, 36 kA thermal-magnetic MCCB within the ABB Protecta Power Devices range.
This MCCB is typically installed within compatible electrical distribution boards, switchgear assemblies and commercial or industrial distribution panels. It is particularly suitable for ABB Protecta Power installations requiring 160 A three-pole outgoing circuit protection.
ABB Protecta Power circuit protection devices combine established Tmax XT circuit breaker technology with practical integration into modern electrical distribution systems. The EPX-XT4N-TM1603 provides dependable 160 A three-pole thermal-magnetic protection and a 36 kA breaking capacity for appropriately specified commercial and industrial installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.