1SDX253483R1 ABB EPX-XT4N-TM1003 Protecta Power XT4N 100A 3-Pole 36kA TMA MCCB

1SDX253483R1 ABB EPX-XT4N-TM1003 Protecta Power XT4N 100A 3-Pole 36kA TMA MCCB

ABB EPX-XT4N-TM1003 Protecta Power 100 A three-pole Tmax XT4N moulded case circuit breaker with 36 kA specified breaking capacity and TMA thermal-magnetic protection for compatible low-voltage electrical distribution assemblies.

SKU: 1SDX253483R1Alt SKU: EPX-XT4N-TM1003MPN: 1SDX253483R1
Price
List Price £586.50 ex VAT
Your Price (ex VAT)
£586.50
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £586.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£586.50

Why Choose the ABB EPX-XT4N-TM1003 100A 3-Pole 36kA MCCB with TMA Protection?

The ABB EPX-XT4N-TM1003 is a 100 A, three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Tmax XT4N circuit breaker family and the Protecta Power Devices range, this MCCB combines a 36 kA specified breaking capacity with thermal-magnetic protection for commercial and industrial electrical installations.

Featuring a TMA thermal-magnetic trip unit, the EPX-XT4N-TM1003 provides protection against sustained overload currents and short-circuit faults. Its thermal protection element responds to prolonged excessive current, while the magnetic element enables rapid interruption when sufficiently high fault currents occur. These complementary protective functions help safeguard electrical conductors, connected equipment and distribution infrastructure.

With its 100 A rated current, three-pole construction and ABB Tmax XT4 platform, the EPX-XT4N-TM1003 is suitable for appropriately designed three-phase outgoing feeders and distribution circuits. Its Protecta Power designation makes it relevant to compatible ABB electrical distribution assemblies where reliable circuit protection and suitable short-circuit interruption capability are required.

Key Advantages

  • 100 A rated current: Provides protection for suitably rated three-phase electrical distribution circuits.
  • Three-pole construction: Enables coordinated switching and protection of three-phase supplies.
  • 36 kA specified breaking capacity: Supports installations with appropriate prospective short-circuit current levels.
  • TMA thermal-magnetic protection: Combines overload and short-circuit protective functions in one MCCB.
  • Adjustable protection characteristics: Supports the selection of suitable thermal and magnetic trip settings.
  • ABB Tmax XT4N technology: Provides established moulded case circuit breaker protection for low-voltage distribution.
  • XT4 frame platform: Offers a circuit breaker family suitable for a range of distribution current ratings.
  • Protecta Power integration: Supports use within compatible ABB distribution assemblies.
  • Manual switching and resetting: Allows straightforward circuit breaker operation and restoration after a trip.
  • Commercial and industrial suitability: Supports electrical protection in a wide range of building and industrial environments.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB Tmax XT4N moulded case circuit breaker family.
  • 100 A rated current.
  • Three-pole configuration for three-phase electrical distribution.
  • 36 kA specified short-circuit breaking capacity.
  • TMA thermal-magnetic trip unit designation.
  • Thermal overload protection against sustained overcurrent conditions.
  • Magnetic short-circuit protection against high fault currents.
  • Adjustable thermal-magnetic protection characteristics.
  • XT4 frame family for low-voltage circuit protection.
  • Common operating mechanism for coordinated three-pole switching.
  • Manual opening, closing and resetting.
  • Designed for integration into compatible ABB Protecta Power distribution equipment.
  • Suitable for three-phase outgoing feeder and sub-distribution circuit protection.
  • ABB manufacturer order code 1SDX253483R1.

Dependable Thermal-Magnetic Protection for Three-Phase Power Distribution

The ABB EPX-XT4N-TM1003 provides circuit protection for three-phase electrical installations requiring a 100 A moulded case circuit breaker. Its TMA thermal-magnetic trip arrangement combines protection against prolonged overloads with magnetic tripping during short-circuit faults. Thermal protection helps limit excessive conductor heating caused by sustained overcurrent, while magnetic protection provides rapid fault interruption when the relevant trip threshold is reached.

The ABB Tmax XT4N platform offers a practical protective solution for compatible Protecta Power distribution assemblies and electrical panels. Its 36 kA specified breaking capacity must be assessed against the prospective short-circuit current and operating voltage of the installation. Electrical designers should also verify conductor sizing, protective coordination, trip adjustment ranges, terminal arrangements, installation clearances and compatibility with the intended distribution assembly.

Typical Applications

  • Compatible ABB Protecta Power electrical distribution assemblies.
  • Commercial and industrial low-voltage distribution boards.
  • Three-phase outgoing feeder protection.
  • Sub-main and sub-distribution electrical circuits.
  • Manufacturing facilities and industrial production environments.
  • Commercial buildings, offices and retail premises.
  • Warehouses, workshops and logistics centres.
  • Electrical plant rooms and building services installations.
  • Distribution circuits supplying industrial machinery and electrical equipment.
  • Electrical panel building and distribution equipment upgrades.
  • Projects requiring 100 A three-pole MCCB protection.
  • Installations requiring a 36 kA thermal-magnetic circuit breaker.

Technical Specifications

Product model EPX-XT4N-TM1003
ABB order code 1SDX253483R1
Product group Protecta Power Devices
Circuit breaker series Tmax XT
Circuit breaker family XT4N
Frame designation XT4
Product type Moulded case circuit breaker (MCCB)
Rated current 100 A
Number of poles 3
Specified breaking capacity 36 kA
Performance designation N
Trip unit designation TMA
Protection technology Thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Trip characteristics Adjustable thermal-magnetic protection
Operating mechanism Manual circuit breaker operation
Electrical system Low-voltage electrical distribution
Distribution arrangement Three-pole, three-phase applications
Installation Compatible ABB Protecta Power distribution assembly
Primary application Overload and short-circuit protection

Frequently Asked Questions

What is the ABB EPX-XT4N-TM1003 used for?

The ABB EPX-XT4N-TM1003 is a 100 A three-pole moulded case circuit breaker designed to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage electrical distribution assemblies.

What is the rated current and breaking capacity of the EPX-XT4N-TM1003?

The EPX-XT4N-TM1003 has a 100 A rated current and a specified 36 kA breaking capacity. The applicable short-circuit breaking capacity must be verified against the operating voltage and prospective fault current of the installation.

What does TMA mean on the ABB EPX-XT4N-TM1003?

TMA identifies the thermal-magnetic trip unit configuration. The thermal element provides protection against sustained overloads, while the magnetic element responds to short-circuit faults. The exact adjustment ranges and trip characteristics should be checked against ABB documentation for the selected device.

Is the ABB EPX-XT4N-TM1003 suitable for three-phase electrical systems?

Yes. The EPX-XT4N-TM1003 has a three-pole configuration suitable for appropriately designed three-phase electrical circuits. Selection must account for the system voltage, prospective short-circuit current, conductor ratings, protective coordination and distribution assembly requirements.

What is the difference between the EPX-XT4N-TM1003 and EPX-XT4S-TM1003?

Both are 100 A, three-pole ABB Tmax XT4 thermal-magnetic MCCBs. The EPX-XT4N-TM1003 has a specified 36 kA breaking capacity, while the EPX-XT4S-TM1003 has a specified 50 kA breaking capacity. The appropriate model depends on the installation's operating voltage, prospective fault current and protective requirements.

Trusted by Electrical Contractors and Panel Builders

ABB Tmax XT circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with established solutions for low-voltage circuit protection. The EPX-XT4N-TM1003 combines a 100 A rated current, three-pole construction, 36 kA specified breaking capacity and TMA thermal-magnetic protection to support dependable electrical distribution in commercial and industrial installations.