ABB EPX-XT4N-TM1003 Protecta Power 100 A three-pole Tmax XT4N moulded case circuit breaker with 36 kA specified breaking capacity and TMA thermal-magnetic protection for compatible low-voltage electrical distribution assemblies.
£586.50
The ABB EPX-XT4N-TM1003 is a 100 A, three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Tmax XT4N circuit breaker family and the Protecta Power Devices range, this MCCB combines a 36 kA specified breaking capacity with thermal-magnetic protection for commercial and industrial electrical installations.
Featuring a TMA thermal-magnetic trip unit, the EPX-XT4N-TM1003 provides protection against sustained overload currents and short-circuit faults. Its thermal protection element responds to prolonged excessive current, while the magnetic element enables rapid interruption when sufficiently high fault currents occur. These complementary protective functions help safeguard electrical conductors, connected equipment and distribution infrastructure.
With its 100 A rated current, three-pole construction and ABB Tmax XT4 platform, the EPX-XT4N-TM1003 is suitable for appropriately designed three-phase outgoing feeders and distribution circuits. Its Protecta Power designation makes it relevant to compatible ABB electrical distribution assemblies where reliable circuit protection and suitable short-circuit interruption capability are required.
The ABB EPX-XT4N-TM1003 provides circuit protection for three-phase electrical installations requiring a 100 A moulded case circuit breaker. Its TMA thermal-magnetic trip arrangement combines protection against prolonged overloads with magnetic tripping during short-circuit faults. Thermal protection helps limit excessive conductor heating caused by sustained overcurrent, while magnetic protection provides rapid fault interruption when the relevant trip threshold is reached.
The ABB Tmax XT4N platform offers a practical protective solution for compatible Protecta Power distribution assemblies and electrical panels. Its 36 kA specified breaking capacity must be assessed against the prospective short-circuit current and operating voltage of the installation. Electrical designers should also verify conductor sizing, protective coordination, trip adjustment ranges, terminal arrangements, installation clearances and compatibility with the intended distribution assembly.
| Product model | EPX-XT4N-TM1003 |
|---|---|
| ABB order code | 1SDX253483R1 |
| Product group | Protecta Power Devices |
| Circuit breaker series | Tmax XT |
| Circuit breaker family | XT4N |
| Frame designation | XT4 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 100 A |
| Number of poles | 3 |
| Specified breaking capacity | 36 kA |
| Performance designation | N |
| Trip unit designation | TMA |
| Protection technology | Thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Trip characteristics | Adjustable thermal-magnetic protection |
| Operating mechanism | Manual circuit breaker operation |
| Electrical system | Low-voltage electrical distribution |
| Distribution arrangement | Three-pole, three-phase applications |
| Installation | Compatible ABB Protecta Power distribution assembly |
| Primary application | Overload and short-circuit protection |
The ABB EPX-XT4N-TM1003 is a 100 A three-pole moulded case circuit breaker designed to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage electrical distribution assemblies.
The EPX-XT4N-TM1003 has a 100 A rated current and a specified 36 kA breaking capacity. The applicable short-circuit breaking capacity must be verified against the operating voltage and prospective fault current of the installation.
TMA identifies the thermal-magnetic trip unit configuration. The thermal element provides protection against sustained overloads, while the magnetic element responds to short-circuit faults. The exact adjustment ranges and trip characteristics should be checked against ABB documentation for the selected device.
Yes. The EPX-XT4N-TM1003 has a three-pole configuration suitable for appropriately designed three-phase electrical circuits. Selection must account for the system voltage, prospective short-circuit current, conductor ratings, protective coordination and distribution assembly requirements.
Both are 100 A, three-pole ABB Tmax XT4 thermal-magnetic MCCBs. The EPX-XT4N-TM1003 has a specified 36 kA breaking capacity, while the EPX-XT4S-TM1003 has a specified 50 kA breaking capacity. The appropriate model depends on the installation's operating voltage, prospective fault current and protective requirements.
ABB Tmax XT circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with established solutions for low-voltage circuit protection. The EPX-XT4N-TM1003 combines a 100 A rated current, three-pole construction, 36 kA specified breaking capacity and TMA thermal-magnetic protection to support dependable electrical distribution in commercial and industrial installations.