1SDX253480R1 ABB EPX-XT4N-TM0503 50A 3-Pole 36kA TMA MCCB

1SDX253480R1 ABB EPX-XT4N-TM0503 50A 3-Pole 36kA TMA MCCB

ABB EPX-XT4N-TM0503 is a 50 A three-pole SACE Tmax XT4N moulded case circuit breaker with a specified 36 kA breaking capacity and thermal-magnetic adjustable protection for compatible ABB Protecta Power distribution assemblies.

SKU: 1SDX253480R1Alt SKU: EPX-XT4N-TM0503MPN: 1SDX253480R1
Price
List Price £576.62 ex VAT
Your Price (ex VAT)
£576.62
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £576.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£576.62

Why Choose the ABB EPX-XT4N-TM0503 50A 3-Pole MCCB?

The ABB EPX-XT4N-TM0503 is a 50 A three-pole moulded case circuit breaker (MCCB) with a 36 kA specified breaking capacity and thermal-magnetic adjustable (TMA) protection. Incorporating the ABB SACE Tmax XT4N circuit breaker designation, this device belongs to the ABB Protecta Power Devices range for low-voltage electrical distribution applications.

Designed to protect electrical circuits against overload and short-circuit conditions, the EPX-XT4N-TM0503 combines thermal overload protection with magnetic short-circuit protection. Its three-pole configuration supports the simultaneous switching and protection of three phase conductors in suitable electrical distribution systems.

With its 50 A rated current, 36 kA breaking capacity and TMA trip protection, this MCCB provides a protective switching solution for compatible ABB Protecta Power distribution assemblies. The exact manufacturer configuration is identified by ABB order code 1SDX253480R1.

Key Advantages

  • 50 A rated current for appropriately designed low-voltage distribution circuits.
  • Three-pole (3P) configuration for simultaneous switching and protection of three phase conductors.
  • 36 kA specified breaking capacity for installations with suitably assessed short-circuit fault levels.
  • Thermal-magnetic adjustable (TMA) protection against overload and short-circuit conditions.
  • Incorporates the ABB SACE Tmax XT4N circuit breaker designation.
  • Supports dependable protective switching within correctly designed electrical distribution systems.
  • Designed for compatible ABB Protecta Power distribution assemblies.
  • Suitable for commercial and industrial low-voltage power distribution applications.

Key Features

  • ABB Protecta Power Devices product range.
  • SACE Tmax XT4N moulded case circuit breaker designation.
  • 50 A rated current.
  • Three-pole (3P) configuration.
  • 36 kA specified breaking capacity.
  • TMA thermal-magnetic adjustable trip protection.
  • Thermal overload protection against sustained overcurrent conditions.
  • Magnetic short-circuit protection against fault currents.
  • Manual circuit switching functionality.
  • Intended for compatible ABB Protecta Power low-voltage distribution equipment.

Reliable 50A Thermal-Magnetic Protection for Three-Phase Circuits

The ABB EPX-XT4N-TM0503 combines a 50 A rated current with a 36 kA specified breaking capacity, making it a suitable candidate for low-voltage distribution circuits requiring these protective characteristics. Its thermal-magnetic adjustable trip arrangement responds to both sustained overload conditions and short-circuit faults.

The thermal protection element responds to excessive current sustained over time, while the magnetic protection element provides a response to short-circuit conditions. Together, these functions help safeguard electrical conductors and connected equipment when the circuit breaker is correctly selected, installed and coordinated with other protective devices.

The three-pole XT4N configuration supports appropriate three-phase electrical distribution applications. Electrical designers should verify the operating voltage, prospective short-circuit current, conductor sizing, protective settings and compatibility with the selected ABB Protecta Power assembly before installation.

Typical Applications

  • ABB Protecta Power low-voltage distribution assemblies.
  • 50 A three-pole outgoing circuit protection.
  • Commercial three-phase electrical distribution boards.
  • Industrial electrical panelboard installations.
  • Three-phase equipment feeder protection.
  • Building services electrical distribution systems.
  • Circuits requiring thermal-magnetic MCCB protection.
  • Installations requiring an appropriately rated 36 kA circuit breaker.
  • Electrical distribution upgrades and refurbishment projects.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
ABB order code 1SDX253480R1
Product type Moulded case circuit breaker (MCCB)
Frame designation XT4
Performance designation XT4N
Rated current 50 A
Number of poles 3
Pole configuration Three-pole (3P)
Specified breaking capacity 36 kA
Trip unit Thermal-magnetic adjustable (TMA)
Overload protection Thermal
Short-circuit protection Magnetic
Electrical application Low-voltage power distribution
Compatible system ABB Protecta Power
Product group Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT4N-TM0503 used for?

The ABB EPX-XT4N-TM0503 is a 50 A three-pole MCCB intended to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage distribution systems.

What is the rated current of the EPX-XT4N-TM0503?

The circuit breaker has a rated current of 50 A.

How many poles does the EPX-XT4N-TM0503 have?

The device has a three-pole (3P) configuration for simultaneous switching and protection of three phase conductors.

What is the breaking capacity of the EPX-XT4N-TM0503?

The device is specified with a 36 kA breaking capacity. The applicable operating voltage and prospective short-circuit current must be checked before installation.

What does TMA mean on this circuit breaker?

TMA means thermal-magnetic adjustable, identifying a protection arrangement that combines thermal overload protection with magnetic short-circuit protection.

Which ABB circuit breaker platform does the EPX-XT4N-TM0503 use?

The product incorporates the ABB SACE Tmax XT4N circuit breaker designation.

What is the difference between the EPX-XT4N-TM0503 and EPX-XT4N-TM0403?

The EPX-XT4N-TM0503 is rated at 50 A, while the EPX-XT4N-TM0403 is rated at 40 A. Both are specified as three-pole XT4N MCCBs with 36 kA breaking capacity and TMA protection.

Does the EPX-XT4N-TM0503 use electronic LSI protection?

No. This configuration is specified with TMA thermal-magnetic adjustable protection, rather than electronic LSI protection.

What is the ABB order code for the EPX-XT4N-TM0503?

The ABB manufacturer order code is 1SDX253480R1.

Trusted by Electrical Contractors and Power Distribution Professionals

The ABB EPX-XT4N-TM0503 50 A Three-Pole MCCB supports electrical contractors, panel builders and distribution system designers specifying a 36 kA XT4N circuit breaker with thermal-magnetic adjustable protection for compatible ABB Protecta Power installations.