Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT4N-TM0403 (1SDX253479R1) is a Protecta Power Devices 40 A, 3-pole moulded case circuit breaker with a specified 36 kA breaking capacity and TMA thermal-magnetic protection for compatible low-voltage electrical distribution systems.
£576.62
The ABB EPX-XT4N-TM0403 is a 40 A, 3-pole moulded case circuit breaker (MCCB) with a specified 36 kA breaking capacity and TMA thermal-magnetic protection. Belonging to the ABB Protecta Power Devices product group, this circuit breaker is designed for low-voltage electrical distribution applications requiring three-pole circuit protection against overloads and short circuits.
The EPX-XT4N-TM0403 combines a 40 A current rating with a three-pole switching arrangement, making it suitable for appropriately designed three-phase electrical distribution circuits. Its thermal-magnetic trip technology provides overload protection through a thermal element and short-circuit protection through a magnetic element, supporting coordinated electrical protection within compatible distribution systems.
Identified by ABB order code 1SDX253479R1, the EPX-XT4N-TM0403 is specified as a 36 kA MCCB with TMA protection. It is intended for electrical contractors, panel builders, consulting engineers and maintenance professionals requiring a manufacturer-specific circuit breaker for compatible ABB Protecta Power installations.
Low-voltage electrical distribution systems require appropriately selected protective devices to reduce the risks associated with overload currents and short-circuit faults. The ABB EPX-XT4N-TM0403 provides a 40 A, three-pole MCCB configuration with TMA thermal-magnetic protection for suitable industrial and commercial electrical installations.
The thermal protection element responds to sustained overload conditions, while the magnetic protection element provides a response to high fault currents associated with short circuits. These complementary protection functions allow a thermal-magnetic MCCB to protect appropriately designed electrical circuits against different overcurrent conditions.
The specified 36 kA breaking capacity is an important consideration when selecting the breaker for an electrical distribution system. The prospective short-circuit current at the installation point must be assessed, and the applicable breaking-capacity rating must be verified against the system voltage and relevant ABB technical data. The stated breaking capacity should not be assumed to apply identically at every operating voltage.
The three-pole configuration enables the breaker to protect and interrupt the three phase conductors of a suitable electrical circuit. The EPX-XT4N-TM0403 should be selected with consideration for conductor sizing, load characteristics, protective device coordination, installation conditions and the requirements of the completed electrical distribution assembly.
As part of the ABB Protecta Power Devices range, the EPX-XT4N-TM0403 should be installed in accordance with the relevant ABB technical documentation. The final installation must satisfy applicable electrical safety requirements, including the relevant provisions of BS EN IEC 60947-2 for circuit breakers and BS EN IEC 61439 where the device forms part of a low-voltage switchgear assembly.
The ABB EPX-XT4N-TM0403 is a 40 A, 3-pole moulded case circuit breaker designed for low-voltage electrical distribution applications. It provides thermal-magnetic overload and short-circuit protection for appropriately designed three-phase circuits.
The EPX-XT4N-TM0403 has a specified 40 A rated current. The circuit breaker must be selected according to the circuit load, conductor characteristics, installation conditions and applicable ABB protection settings.
The 36 kA rating identifies the specified short-circuit breaking capacity of the MCCB. The applicable breaking capacity must be confirmed at the intended operating voltage and compared with the prospective fault current at the installation point using ABB technical documentation.
TMA identifies the breaker's thermal-magnetic protection arrangement. Thermal protection responds to sustained overload conditions, while magnetic protection responds to short-circuit currents. The exact adjustment capabilities and protection characteristics should be confirmed from the applicable ABB product documentation.
The official ABB order code is 1SDX253479R1. The manufacturer product designation is EPX-XT4N-TM0403, identifying a 40 A, 3-pole, 36 kA thermal-magnetic MCCB within the ABB Protecta Power Devices product group.
ABB Protecta Power Devices provide circuit protection solutions for professional low-voltage electrical distribution installations. The EPX-XT4N-TM0403 combines a 40 A current rating, three-pole construction, specified 36 kA breaking capacity and TMA thermal-magnetic protection, supporting appropriately engineered industrial and commercial electrical distribution systems.