1SDX253477R1 ABB EPX-XT4N-TM0253 25A 3-Pole 36kA TMA MCCB

1SDX253477R1 ABB EPX-XT4N-TM0253 25A 3-Pole 36kA TMA MCCB

ABB EPX-XT4N-TM0253 is a 25 A three-pole SACE Tmax XT4N moulded case circuit breaker with a specified 36 kA breaking capacity and thermal-magnetic adjustable protection for compatible ABB Protecta Power distribution assemblies.

SKU: 1SDX253477R1Alt SKU: EPX-XT4N-TM0253MPN: 1SDX253477R1
Price
List Price £576.62 ex VAT
Your Price (ex VAT)
£576.62
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £576.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£576.62

Why Choose the ABB EPX-XT4N-TM0253 25A 3-Pole MCCB?

The ABB EPX-XT4N-TM0253 is a 25 A three-pole moulded case circuit breaker (MCCB) featuring a 36 kA specified breaking capacity and thermal-magnetic adjustable (TMA) protection. Incorporating the ABB SACE Tmax XT4N circuit breaker designation, this device belongs to the ABB Protecta Power Devices range for low-voltage electrical distribution applications.

Designed to protect electrical circuits against overload and short-circuit conditions, the EPX-XT4N-TM0253 combines thermal overload protection with magnetic short-circuit protection. Its three-pole configuration supports simultaneous switching and protection of three phase conductors in appropriately designed electrical installations.

With a 25 A rated current, 36 kA breaking capacity and TMA trip protection, this MCCB provides a specified circuit protection solution for compatible ABB Protecta Power distribution assemblies. The exact manufacturer configuration is identified by ABB order code 1SDX253477R1.

Key Advantages

  • 25 A rated current for appropriately designed low-voltage distribution circuits.
  • Three-pole (3P) configuration for simultaneous switching and protection of three phase conductors.
  • 36 kA specified breaking capacity for installations with suitably assessed short-circuit fault levels.
  • Thermal-magnetic adjustable (TMA) protection against overload and short-circuit conditions.
  • Incorporates the ABB SACE Tmax XT4N circuit breaker designation.
  • Combines a 25 A current rating with substantial specified fault-interruption capability.
  • Designed for compatible ABB Protecta Power distribution assemblies.
  • Suitable for commercial and industrial low-voltage distribution applications.

Key Features

  • ABB Protecta Power Devices product range.
  • SACE Tmax XT4N moulded case circuit breaker designation.
  • 25 A rated current.
  • Three-pole (3P) configuration.
  • 36 kA specified breaking capacity.
  • TMA thermal-magnetic adjustable trip protection.
  • Thermal overload protection against sustained overcurrent conditions.
  • Magnetic short-circuit protection against fault currents.
  • Manual circuit switching functionality.
  • Intended for compatible ABB Protecta Power low-voltage distribution equipment.

Reliable 25A Thermal-Magnetic Protection for Three-Phase Circuits

The ABB EPX-XT4N-TM0253 combines a 25 A rated current with a 36 kA specified breaking capacity, providing a circuit protection option for appropriately designed low-voltage distribution systems. Its thermal-magnetic adjustable protection arrangement responds to both sustained overloads and short-circuit faults.

The thermal protection element responds to excessive current sustained over time, while the magnetic protection element provides a response to short-circuit conditions. These complementary functions help protect electrical conductors and connected equipment when the MCCB is correctly selected, installed and coordinated with other protective devices.

The three-pole XT4N configuration supports suitable three-phase electrical distribution applications. Electrical designers should confirm the operating voltage, prospective short-circuit current, conductor sizing, protective settings and compatibility with the selected ABB Protecta Power assembly before installation.

Typical Applications

  • ABB Protecta Power low-voltage distribution assemblies.
  • 25 A three-pole outgoing circuit protection.
  • Commercial three-phase electrical distribution boards.
  • Industrial electrical panelboard installations.
  • Three-phase equipment feeder protection.
  • Building services electrical distribution systems.
  • Circuits requiring thermal-magnetic MCCB protection.
  • Installations requiring an appropriately rated 36 kA circuit breaker.
  • Electrical distribution upgrades and refurbishment projects.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker family SACE Tmax XT
ABB order code 1SDX253477R1
Product type Moulded case circuit breaker (MCCB)
Frame designation XT4
Performance designation XT4N
Rated current 25 A
Number of poles 3
Pole configuration Three-pole (3P)
Specified breaking capacity 36 kA
Trip unit Thermal-magnetic adjustable (TMA)
Overload protection Thermal
Short-circuit protection Magnetic
Electrical application Low-voltage power distribution
Compatible system ABB Protecta Power
Product group Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-XT4N-TM0253 used for?

The ABB EPX-XT4N-TM0253 is a 25 A three-pole MCCB intended to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage distribution systems.

What is the rated current of the EPX-XT4N-TM0253?

The circuit breaker has a rated current of 25 A.

How many poles does the EPX-XT4N-TM0253 have?

The device has a three-pole (3P) configuration for simultaneous switching and protection of three phase conductors.

What is the breaking capacity of the EPX-XT4N-TM0253?

The device is specified with a 36 kA breaking capacity. The applicable operating voltage and prospective short-circuit current must be checked before installation.

What does TMA mean on this circuit breaker?

TMA means thermal-magnetic adjustable, identifying a trip protection arrangement that combines thermal overload protection with magnetic short-circuit protection.

Which ABB circuit breaker platform does the EPX-XT4N-TM0253 use?

The product incorporates the ABB SACE Tmax XT4N circuit breaker designation.

Does the EPX-XT4N-TM0253 use electronic LSI protection?

No. This specific configuration is specified with TMA thermal-magnetic adjustable protection, rather than electronic LSI protection.

Is the EPX-XT4N-TM0253 suitable for ABB Protecta Power distribution boards?

The device belongs to the ABB Protecta Power Devices range and is intended for compatible distribution assemblies. The specific board, mounting and connection arrangements should be confirmed before installation.

What is the ABB order code for the EPX-XT4N-TM0253?

The ABB manufacturer order code is 1SDX253477R1.

Trusted by Electrical Contractors and Power Distribution Professionals

The ABB EPX-XT4N-TM0253 25 A Three-Pole MCCB supports electrical contractors, panel builders and distribution system designers specifying a 36 kA XT4N circuit breaker with thermal-magnetic adjustable protection for compatible ABB Protecta Power installations.