ABB EPX-XT4N-TM0163 is a 16 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and thermal-magnetic protection, designed for commercial and industrial electrical distribution systems.
£576.62
The ABB EPX-XT4N-TM0163 is a robust and reliable 16 A three-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in commercial and industrial electrical distribution systems. As part of the ABB Protecta Power Devices range, this circuit breaker combines proven thermal-magnetic protection technology with a 36 kA short-circuit breaking capacity, making it suitable for demanding low-voltage power distribution applications.
Based on the ABB XT4N circuit breaker platform, the EPX-XT4N-TM0163 is designed for dependable circuit protection and straightforward integration into compatible electrical distribution assemblies. Its thermal-magnetic trip mechanism provides protection against sustained overload conditions and high short-circuit currents, helping protect electrical installations, cables and connected equipment. The XT4 frame offers a practical combination of mechanical durability, protective performance and installation flexibility.
With a 16 A rated current, three-pole configuration and 36 kA breaking capacity, the ABB EPX-XT4N-TM0163 is suitable for appropriately designed three-phase electrical circuits in commercial buildings, industrial facilities and power distribution installations. Identified by ABB order code 1SDX253474R1, this MCCB belongs to the Protecta Power range and is designed for use with compatible ABB electrical distribution equipment.
Moulded case circuit breakers such as the ABB EPX-XT4N-TM0163 are essential protective devices within low-voltage electrical distribution systems. They monitor the current flowing through protected circuits and automatically interrupt the electrical supply when overload or short-circuit conditions cause the protective trip mechanism to operate. This helps reduce the risk of excessive conductor heating, electrical equipment damage and disruption caused by electrical faults.
The thermal-magnetic protection system combines two complementary protective functions. The thermal element responds to sustained overload currents, while the magnetic element provides rapid operation when high fault currents occur. Together, these functions deliver effective protection for appropriately rated electrical circuits without requiring a separate electronic protection unit.
The ABB XT4N frame provides a robust platform for three-pole circuit protection. Although the XT4 frame family accommodates higher current ratings, the EPX-XT4N-TM0163 is specifically rated at 16 A. Its 36 kA breaking capacity supports applications where the prospective short-circuit current requires a suitably rated protective device. Circuit breaker selection must account for the installation voltage, fault level, cable characteristics and applicable electrical installation requirements.
Designed for the ABB Protecta Power distribution system, this MCCB can be incorporated into compatible panelboard assemblies using the appropriate mounting components. The XT4 three-pole outgoing MCCB base plate and cover are identified by EPX-BPCXT4-3P and are specified separately within the Protecta Power range. This modular arrangement supports practical installation, circuit organisation and maintenance within commercial and industrial electrical distribution systems.
| Product group | Protecta Power Devices |
|---|---|
| Series | Protecta Power / XT4N |
| ABB order code | 1SDX253474R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 16 A |
| Number of poles | 3 |
| Electrical configuration | Three-phase |
| Short-circuit breaking capacity | 36 kA |
| Protection technology | Thermal-magnetic |
| Trip unit designation | TMA (Protecta Power catalogue designation) |
| Protection functions | Overload and short-circuit protection |
| Frame family | XT4 |
| Frame performance designation | N |
| XT4 frame current class | 160 A |
| Device width | 110 mm |
| Mounting application | Compatible electrical distribution assemblies |
| Compatible Protecta Power base plate and cover | EPX-BPCXT4-3P |
| Application category | Low-voltage electrical power distribution |
| Typical installation | ABB Protecta Power panelboards and compatible distribution equipment |
The ABB EPX-XT4N-TM0163 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial installations, including compatible ABB Protecta Power distribution assemblies.
The circuit breaker has a rated current of 16 A. It is intended for appropriately designed electrical circuits requiring 16 A overcurrent protection.
The ABB EPX-XT4N-TM0163 has a specified 36 kA short-circuit breaking capacity. The suitability of this rating must be assessed against the prospective fault current, operating voltage and applicable installation conditions.
This MCCB uses thermal-magnetic protection to respond to overload and short-circuit faults. The thermal element operates during sustained overload conditions, while the magnetic element provides rapid protection against high short-circuit currents.
The circuit breaker is designed for installation within compatible ABB Protecta Power panelboards and electrical distribution assemblies. The corresponding XT4 three-pole outgoing MCCB base plate and cover, identified by EPX-BPCXT4-3P, are specified separately for compatible Protecta Power installations.
ABB Protecta Power protective devices combine established thermal-magnetic circuit protection technology with practical electrical distribution solutions. The EPX-XT4N-TM0163 offers a robust 16 A, three-pole XT4N MCCB configuration with a 36 kA breaking capacity, supporting reliable protection in commercial and industrial low-voltage distribution installations.