1SDX253473R1 ABB EPX-XT2N-TM1603 160A 3P 36kA TMA Moulded Case Circuit Breaker

1SDX253473R1 ABB EPX-XT2N-TM1603 160A 3P 36kA TMA Moulded Case Circuit Breaker

ABB EPX-XT2N-TM1603 (1SDX253473R1) is a 160 A three-pole SACE Tmax XT2N moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and thermal-magnetic adjustable protection for compatible ABB Protecta Power electrical distribution systems.

SKU: 1SDX253473R1Alt SKU: EPX-XT2N-TM1603MPN: 1SDX253473R1
Price
List Price £640.76 ex VAT
Your Price (ex VAT)
£640.76
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £640.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£640.76

Why Choose the ABB EPX-XT2N-TM1603 160A 3-Pole Moulded Case Circuit Breaker?

The ABB EPX-XT2N-TM1603 is a high-performance 160 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Built around the established ABB SACE Tmax XT2N160 circuit breaker platform, this device combines robust circuit protection with a compact construction suitable for commercial, industrial and building services installations.

As part of the ABB Protecta Power Devices product group, the EPX-XT2N-TM1603 is intended for integration into compatible ABB Protecta Power distribution assemblies. Its thermal-magnetic adjustable (TMA) trip configuration provides protection against sustained overload conditions and short-circuit faults, helping safeguard electrical cables, connected equipment and distribution infrastructure. The three-pole construction enables coordinated switching and protection of all three phase conductors.

With a 160 A rated current, a specified 36 kA short-circuit breaking capacity and a three-pole (3P) configuration, the EPX-XT2N-TM1603 is well suited to outgoing feeder protection in three-phase distribution systems. Its compact 90 mm nominal device width helps maximise available distribution board space, making it a practical choice for electrical contractors, panel builders, switchboard manufacturers and facilities engineers.

Key Advantages

  • High-capacity 160 A moulded case circuit breaker for commercial and industrial low-voltage power distribution.
  • 36 kA short-circuit breaking capacity in the specified ABB Protecta Power configuration.
  • Three-pole (3P) construction for coordinated protection and switching of three-phase circuits.
  • Thermal-magnetic adjustable (TMA) protection against overloads and short-circuit faults.
  • Based on the established ABB SACE Tmax XT2N160 platform.
  • Compact 90 mm nominal width helps conserve valuable distribution board space.
  • Designed for integration into ABB Protecta Power distribution boards.
  • Thermal-magnetic trip characteristics support appropriate protection coordination with connected cables and electrical equipment.
  • Robust moulded case construction provides reliable operation in demanding electrical environments.
  • Suitable for new electrical installations, distribution board upgrades and industrial power distribution projects.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT2N-TM1603 product designation.
  • ABB order code 1SDX253473R1.
  • ABB SACE Tmax XT2N160 circuit breaker platform.
  • 160 A rated current for three-phase outgoing circuit protection.
  • 160 A frame rating within the XT2N160 platform.
  • 36 kA specified short-circuit breaking capacity.
  • Three-pole (3P) configuration for simultaneous switching of three phase conductors.
  • Thermal-magnetic adjustable (TMA) trip configuration for overload and short-circuit protection.
  • Thermal overload protection responds to sustained excessive current.
  • Magnetic short-circuit protection provides rapid fault interruption.
  • 90 mm nominal device width for compact electrical distribution assemblies.
  • Manual operating mechanism for circuit switching and isolation when correctly installed.
  • Designed for installation using compatible ABB Protecta Power mounting and connection accessories.
  • Suitable for commercial, industrial and building services electrical distribution systems.

Reliable Three-Phase Circuit Protection for Low-Voltage Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT2N-TM1603 protect electrical distribution systems by automatically interrupting current when overload or short-circuit conditions occur. The thermal protection element responds to sustained excessive current, while the magnetic protection element operates rapidly during short-circuit faults. This combined protection helps reduce the risk of cable damage, equipment failure and disruption to essential electrical distribution infrastructure.

The ABB SACE Tmax XT2N160 platform provides dependable low-voltage circuit protection in a compact moulded case design. Its three-pole configuration enables coordinated switching and protection of all three phase conductors, making the EPX-XT2N-TM1603 suitable for three-phase outgoing feeders and distribution circuits. The thermal-magnetic trip configuration supports appropriate protection coordination with connected cables, electrical loads and downstream protective devices.

The 160 A rated current makes this breaker suitable for appropriately designed high-current outgoing circuits, while its 36 kA specified breaking capacity provides substantial short-circuit interruption capability for compatible distribution applications. The 90 mm nominal width helps optimise available space within electrical distribution boards, making the device suitable for both new installations and upgrades to existing ABB Protecta Power assemblies.

Correct circuit breaker selection should consider the installation operating voltage, prospective short-circuit current, conductor sizing and protective device coordination. The applicable breaking capacity, thermal-magnetic adjustment settings and mounting accessories should be assessed against the complete electrical installation design and relevant ABB technical documentation.

Typical Applications

  • ABB Protecta Power low-voltage electrical distribution boards.
  • Three-phase outgoing feeder protection in commercial buildings.
  • Industrial electrical distribution panels and manufacturing facilities.
  • Three-phase electrical supply circuits for machinery and equipment.
  • Commercial building main and sub-distribution installations.
  • Electrical distribution for warehouses, workshops and logistics facilities.
  • Building services infrastructure and mechanical plant electrical supplies.
  • Electrical switchboard manufacturing and power distribution panel assembly.

Technical Specifications

Product group Protecta Power Devices
Series SACE Tmax XT
Circuit breaker platform XT2N160
ABB order code 1SDX253473R1
Product type Moulded case circuit breaker (MCCB)
Rated current 160 A
Frame rating 160 A
Breaking capacity 36 kA (specified Protecta Power application)
Number of poles 3
Pole configuration Three-pole (3P)
Trip configuration Thermal-magnetic adjustable (TMA)
Trip technology Thermal-magnetic
Thermal protection Overload protection
Magnetic protection Short-circuit protection
Protection functions Overload and short-circuit protection
Applicable circuit breaker standard IEC 60947-2
Nominal device width 90 mm
Mounting type Compatible ABB Protecta Power distribution assembly
Installation Fixed distribution board installation using compatible mounting and connection accessories
Application Three-phase low-voltage electrical power distribution

Frequently Asked Questions

What is the ABB EPX-XT2N-TM1603 used for?

The ABB EPX-XT2N-TM1603 is a 160 A three-pole moulded case circuit breaker designed to protect three-phase electrical distribution circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems.

What is the rated current and breaking capacity of this circuit breaker?

The EPX-XT2N-TM1603 has a 160 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB XT2N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be assessed against the installation operating voltage and prospective fault current.

What does TMA mean on the ABB EPX-XT2N-TM1603?

TMA stands for Thermal-Magnetic Adjustable. This protection technology combines thermal overload detection with magnetic short-circuit protection. The trip characteristics support coordination with electrical cables and connected equipment. Exact adjustment ranges should be confirmed against the specific ABB XT2N160 trip release fitted to the breaker.

What is the advantage of the three-pole configuration?

The three-pole (3P) configuration enables coordinated switching and protection of three phase conductors. This makes the EPX-XT2N-TM1603 suitable for three-phase electrical distribution circuits and appropriately designed equipment supplies. Unlike a four-pole circuit breaker, it does not provide a dedicated switched neutral pole.

Where is the ABB EPX-XT2N-TM1603 typically installed?

The breaker is designed for installation within compatible ABB Protecta Power distribution boards, where it provides outgoing circuit protection. The ABB XT2N three-pole platform has a nominal width of 90 mm, making it suitable for compact electrical distribution assemblies. Compatible mounting and connection accessories should be selected for the installation.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely specified by electrical engineers, contractors and panel builders for dependable low-voltage power distribution. The EPX-XT2N-TM1603 combines 160 A circuit protection, three-pole switching, 36 kA specified short-circuit breaking capacity and thermal-magnetic protection to support reliable electrical installations in commercial and industrial ABB Protecta Power distribution systems.