ABB EPX-XT2N-TM1003 Protecta Power 100 A three-pole Tmax XT2N moulded case circuit breaker with 36 kA specified breaking capacity and adjustable TMA thermal-magnetic protection for compatible low-voltage electrical distribution assemblies.
£452.65
The ABB EPX-XT2N-TM1003 is a 100 A, three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Tmax XT2N circuit breaker family and the Protecta Power Devices range, this MCCB combines a 36 kA specified breaking capacity with adjustable thermal-magnetic protection for commercial and industrial installations.
Featuring a TMA thermal-magnetic trip unit, the EPX-XT2N-TM1003 provides protection against sustained overload currents and short-circuit faults. The thermal element responds to prolonged excessive current, while the magnetic element provides rapid interruption when a sufficiently high fault current occurs. The adjustable protection characteristics of the XT2 TMA platform support appropriate coordination with electrical loads and other protective devices.
With its 100 A rated current, three-pole construction and XT2N 160 A frame platform, the EPX-XT2N-TM1003 is suitable for appropriately designed three-phase outgoing feeders and sub-distribution circuits. Its Protecta Power configuration supports integration into compatible ABB distribution assemblies, offering electrical contractors and panel builders a practical solution for dependable circuit protection.
The ABB EPX-XT2N-TM1003 provides protection for three-phase electrical installations requiring a 100 A moulded case circuit breaker. Its TMA trip unit combines thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained overcurrent conditions that can cause excessive conductor heating, while the magnetic element responds to higher fault currents requiring rapid interruption.
The ABB Tmax XT2N platform offers adjustable thermal-magnetic protection within the XT2 frame family. The device's 100 A rating identifies its rated current, while the 160 A frame class identifies the broader circuit breaker platform. Its 36 kA specified breaking capacity must be assessed against the prospective short-circuit current and operating voltage of the installation. Electrical designers should also verify conductor sizing, protective coordination, trip settings, terminal arrangements and compatibility with the intended Protecta Power assembly.
| Product model | EPX-XT2N-TM1003 |
|---|---|
| ABB order code | 1SDX253471R1 |
| Product group | Protecta Power Devices |
| Circuit breaker series | Tmax XT |
| Circuit breaker family | XT2N |
| Frame designation | XT2 |
| Frame current class | 160 A |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 100 A |
| Number of poles | 3 |
| Specified breaking capacity | 36 kA |
| Performance designation | N |
| Trip unit designation | TMA |
| Protection technology | Adjustable thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Three-pole device width | 100 mm |
| Operating mechanism | Manual circuit breaker operation |
| Electrical system | Low-voltage electrical distribution |
| Distribution arrangement | Three-pole, three-phase applications |
| Installation | Compatible ABB Protecta Power distribution assembly |
| Primary application | Overload and short-circuit protection |
The ABB EPX-XT2N-TM1003 is a 100 A three-pole moulded case circuit breaker designed to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage electrical distribution assemblies.
The EPX-XT2N-TM1003 has a 100 A rated current and a specified 36 kA breaking capacity. The applicable breaking capacity must be verified against the installation's operating voltage and prospective short-circuit current.
TMA identifies an adjustable thermal-magnetic trip unit. The thermal element provides overload protection, while the magnetic element responds to short-circuit faults. The appropriate settings must be selected according to the circuit design and verified against ABB technical documentation.
The EPX-XT2N-TM1003 belongs to the XT2 160 A frame family but has an actual rated current of 100 A. The Protecta Power XT2 three-pole configuration has a specified device width of 100 mm. Additional space may be required for terminals, wiring and installation clearances.
Both models are 100 A three-pole ABB Tmax XT2 thermal-magnetic MCCBs. The EPX-XT2N-TM1003 has a specified 36 kA breaking capacity, while the EPX-XT2S-TM1003 has a specified 50 kA breaking capacity. Selection depends on the prospective short-circuit current, operating voltage and protection requirements of the installation.
ABB Tmax XT circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with established solutions for low-voltage circuit protection. The EPX-XT2N-TM1003 combines a 100 A rated current, three-pole construction, 36 kA specified breaking capacity and adjustable TMA thermal-magnetic protection to support dependable power distribution in commercial and industrial installations.