1SDX253470R1 ABB EPX-XT2N-TM0803 Protecta Power XT2N 80A 3-Pole 36kA TMA MCCB

1SDX253470R1 ABB EPX-XT2N-TM0803 Protecta Power XT2N 80A 3-Pole 36kA TMA MCCB

ABB EPX-XT2N-TM0803 Protecta Power 80 A three-pole Tmax XT2N moulded case circuit breaker with 36 kA specified breaking capacity and TMA thermal-magnetic protection for compatible low-voltage electrical distribution assemblies.

SKU: 1SDX253470R1Alt SKU: EPX-XT2N-TM0803MPN: 1SDX253470R1
Price
List Price £452.65 ex VAT
Your Price (ex VAT)
£452.65
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £452.65
Trade pricing is personalised to your account

Manufacturer Lead Time

£452.65

Why Choose the ABB EPX-XT2N-TM0803 80A 3-Pole 36kA MCCB with TMA Protection?

The ABB EPX-XT2N-TM0803 is an 80 A, three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Tmax XT2N circuit breaker family and the Protecta Power Devices range, this protective device combines a 36 kA breaking capacity with thermal-magnetic trip technology for commercial and industrial electrical installations.

Equipped with a TMA thermal-magnetic trip unit, the EPX-XT2N-TM0803 provides protection against sustained overload currents and short-circuit faults. Its thermal protection element responds to prolonged overcurrent conditions, while its magnetic protection element responds rapidly to high fault currents. The TMA arrangement offers configurable protection characteristics for appropriately designed distribution circuits.

With an 80 A rated current, three-pole construction and the established ABB Tmax XT2N platform, the EPX-XT2N-TM0803 is suitable for three-phase outgoing feeders and sub-distribution circuits. Its Protecta Power designation makes it relevant to compatible ABB distribution assemblies where dependable circuit protection, compact construction and appropriate fault interruption capability are essential.

Key Advantages

  • 80 A rated current: Provides protection for suitably rated three-phase distribution circuits.
  • Three-pole construction: Enables coordinated switching and protection of three-phase electrical supplies.
  • 36 kA breaking capacity: Supports applications with significant prospective short-circuit currents, subject to the applicable operating voltage.
  • TMA thermal-magnetic protection: Combines overload and short-circuit protection in one MCCB.
  • Adjustable protection characteristics: Supports suitable coordination with electrical loads and downstream protective devices.
  • ABB Tmax XT2N platform: Provides established circuit breaker technology for low-voltage power distribution.
  • Compact XT2 construction: Supports efficient electrical panel design and equipment integration.
  • Protecta Power range: Suitable for consideration in compatible ABB Protecta Power distribution assemblies.
  • Manual operation: Allows straightforward switching and resetting following a protective trip.

Key Features

  • ABB Protecta Power Devices product range.
  • ABB Tmax XT2N moulded case circuit breaker family.
  • 80 A rated current.
  • Three-pole configuration for three-phase distribution.
  • 36 kA specified short-circuit breaking capacity.
  • TMA thermal-magnetic trip unit designation.
  • Thermal overload protection against sustained excessive current.
  • Magnetic short-circuit protection against high fault currents.
  • Adjustable thermal-magnetic protection characteristics associated with the XT2 TMA platform.
  • XT2 160 A frame family with an 80 A protective rating.
  • Common operating mechanism for coordinated three-pole switching.
  • Manual circuit breaker operation and resetting.
  • Suitable for outgoing feeder protection within appropriately designed distribution assemblies.
  • ABB manufacturer order code 1SDX253470R1.

Reliable Thermal-Magnetic Protection for Three-Phase Power Distribution

The ABB EPX-XT2N-TM0803 provides protection for three-phase electrical circuits requiring an 80 A moulded case circuit breaker. Its thermal-magnetic trip unit combines protection against prolonged overloads with magnetic tripping during short-circuit faults. Thermal protection helps limit excessive conductor heating, while magnetic protection enables rapid fault interruption when the relevant trip threshold is reached.

The ABB Tmax XT2N platform offers thermal-magnetic protection within the XT2 frame family. Its specified 36 kA breaking capacity makes it suitable for consideration in distribution systems where the prospective short-circuit current is within the circuit breaker's applicable rating. Electrical designers should verify operating voltage, cable sizing, trip settings, protective coordination, terminal arrangements and compatibility with the intended Protecta Power assembly before installation.

Typical Applications

  • Compatible ABB Protecta Power electrical distribution assemblies.
  • Commercial and industrial low-voltage distribution boards.
  • Three-phase outgoing feeder protection.
  • Sub-main and sub-distribution electrical circuits.
  • Manufacturing facilities and industrial production environments.
  • Commercial buildings, offices and retail premises.
  • Warehouses, workshops and logistics centres.
  • Electrical plant rooms and building services installations.
  • Distribution circuits supplying industrial equipment and machinery.
  • Panel building projects requiring 80 A three-pole MCCB protection.
  • Electrical installations requiring a 36 kA thermal-magnetic circuit breaker.

Technical Specifications

Product model EPX-XT2N-TM0803
ABB order code 1SDX253470R1
Product group Protecta Power Devices
Circuit breaker series Tmax XT
Circuit breaker family XT2N
Frame designation XT2
Frame current class 160 A
Product type Moulded case circuit breaker (MCCB)
Rated current 80 A
Number of poles 3
Specified breaking capacity 36 kA
Performance designation N
Trip unit designation TMA
Protection technology Thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Protection arrangement Adjustable thermal-magnetic
Operating mechanism Manual circuit breaker operation
Electrical system Low-voltage electrical distribution
Distribution arrangement Three-pole, three-phase applications
Installation Compatible ABB Protecta Power distribution assembly
Primary application Overload and short-circuit protection

Frequently Asked Questions

What is the ABB EPX-XT2N-TM0803 used for?

The ABB EPX-XT2N-TM0803 is an 80 A three-pole moulded case circuit breaker designed to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage electrical distribution assemblies.

What is the rated current and breaking capacity of the EPX-XT2N-TM0803?

The EPX-XT2N-TM0803 has an 80 A rated current and a specified 36 kA breaking capacity. The applicable breaking capacity must be checked against the installation's operating voltage and prospective short-circuit current.

What does TMA mean on the ABB EPX-XT2N-TM0803?

TMA identifies an adjustable thermal-magnetic trip unit. The thermal element provides overload protection, while the magnetic element responds to short-circuit faults. The applicable trip settings and adjustment ranges should be verified against the ABB documentation for the exact configuration.

What is the difference between the ABB XT2 frame rating and the 80A current rating?

The EPX-XT2N-TM0803 belongs to the XT2 160 A frame family, but its actual protective current rating is 80 A. The frame designation identifies the circuit breaker platform and does not increase the rated current of this particular device.

What is the difference between the EPX-XT2N-TM0803 and EPX-XT2S-TM0803?

Both models are 80 A, three-pole ABB Tmax XT2 thermal-magnetic MCCBs. The EPX-XT2N-TM0803 has a specified 36 kA breaking capacity, while the EPX-XT2S-TM0803 has a specified 50 kA breaking capacity. The appropriate model depends on the installation's prospective fault current, operating voltage and protective requirements.

Trusted by Electrical Contractors and Panel Builders

ABB Tmax XT circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with established solutions for low-voltage electrical protection. The EPX-XT2N-TM0803 combines an 80 A rated current, three-pole construction, 36 kA specified breaking capacity and TMA thermal-magnetic protection to support dependable power distribution in commercial and industrial installations.